9,148 research outputs found

    Acoustic particle palpation for measuring tissue elasticity

    Get PDF
    We propose acoustic particle palpation – the use of sound to press a population of acoustic particles against an interface – as a method for measuring the qualitative and quantitative mechanical properties of materials. We tested the feasibility of this method by emitting ultrasound pulses across a tunnel of an elastic material filled with microbubbles. Ultrasound stimulated the microbubble cloud to move in the direction of wave propagation, press against the distal surface, and cause deformations relevant for elasticity measurements. Shear waves propagated away from the palpation site with a velocity that was used to estimate the material’s Young’s modulus

    Superharmonic microbubble Doppler effect in ultrasound therapy

    No full text
    The introduction of microbubbles in focused ultrasound therapies has enabled a diverse range of non-invasive technologies: sonoporation to deliver drugs into cells, sonothrombolysis to dissolve blood clots, and blood-brain barrier opening to deliver drugs into the brain. Current methods for passively monitoring the microbubble dynamics responsible for these therapeutic effects can identify the cavitation position by passive acoustic mapping and cavitation mode by spectral analysis. Here, we introduce a new feature that can be monitored: microbubble effective velocity. Previous studies have shown that echoes from short imaging pulses had a Doppler shift that was produced by the movement of microbubbles. Therapeutic pulses are longer (>1,000 cycles) and thus produce a larger alteration of microbubble distribution due to primary and secondary acoustic radiation force effects which cannot be monitored using pulse-echo techniques. In our experiments, we captured and analysed the Doppler shift during long therapeutic pulses using a passive cavitation detector. A population of microbubbles (5×104-5×107 microbubbles ml-1) was embedded in a vessel (inner diameter: 4mm) and sonicated using a 0.5 megahertz focused ultrasound transducer (peak-rarefactional pressure: 75-366 kPa, pulse length: 50,000 cycles or 100 milliseconds) within a water tank. Microbubble acoustic emissions were captured with a coaxially aligned 7.5 megahertz passive cavitation detector and spectrally analysed to measure the Doppler shift for multiple harmonics above the 10th harmonic (i.e., superharmonics). A Doppler shift was observed on the order of tens of kilohertz with respect to the primary superharmonic peak and is due to the axial movement of the microbubbles. The position, amplitude and width of the Doppler peaks depended on the acoustic pressure and the microbubble concentration. Higher pressures increased the effective velocity of the microbubbles up to 3m/s, prior to the onset of broadband emission, which is an indicator for high magnitude inertial cavitation. Although the microbubble redistribution was shown to persist for the entire sonication period in dense populations, it was constrained to the first few milliseconds in lower concentrations. In conclusion, superharmonic microbubble Doppler effects can provide a quantitative measure of effective velocities of a sonicated microbubble population and could be used for monitoring ultrasound therapy in real-time

    Displacement of a bubble by acoustic radiation force into a fluid-tissue interface.

    Get PDF
    Microbubbles in an ultrasound beam experience a primary Bjerknes force, which pushes the microbubbles against a fluid-tissue interface and deforms the tissue. This interaction has been used to measure tissue elasticity and is a common interaction in many therapeutic and diagnostic applications, but the mechanisms of deformation, and how the deformation dynamic depends on the bubble and ultrasound parameters, remain unknown. In this study, a mathematical model is proposed for the displacement of a bubble onto a fluid-tissue interface and the tissue deformation in response to the primary Bjerknes force. First, a model was derived for static loading and the model's prediction of bubble-mediated tissue displacement and stresses in tissue were explored. Second, the model was updated for dynamic loading. The results showed that the bubble is both displaced by the applied force and changes its shape. The bubble displacement changes nonlinearly with the applied force. The stress values in tissue are quite high for a distance within one radius of the bubble from the bubble surface. The model proposed here is permissible in human tissue and can be used for biomedical ultrasound applications, including material characterization

    Oxetane ethers are formed reversibly in the lithium-catalyzed Friedel-Crafts alkylation of phenols with oxetanols: synthesis of dihydrobenzofurans, diaryloxetanes, and oxetane ethers

    Get PDF
    Studies on the mechanism and intermediate products in the Friedel–Crafts reaction between oxetanols and phenols are presented. Formation of O-alkylated intermediates is identified using 1H NMR spectroscopy, in a reversible formation of the kinetic oxetane ether products. An interesting relationship between the electronic nature of the nucleophile and the degree of O-alkylation is uncovered. For phenols substituted with an electron withdrawing group such as CN, oxetane ethers are the only products isolated regardless of reaction time. Increasing the electron rich nature of the phenol leads to an increased proportion of the thermodynamic C-alkylated Friedel–Crafts products after just one hour and as the sole product/s after extended reaction times. These studies have enabled a more complete catalytic cycle to be proposed. Using the same lithium catalyst and carefully selected reaction times, several examples of oxetane ethers are successfully isolated as novel bioisosteres for ester groups

    Reduction of Motion Artifacts and Improvement of R Peak Detecting Accuracy Using Adjacent Non-Intrusive ECG Sensors

    Get PDF
    Non-intrusive electrocardiogram (ECG) monitoring has many advantages: easy to measure and apply in daily life. However, motion noise in the measured signal is the major problem of non-intrusive measurement. This paper proposes a method to reduce the noise and to detect the R peaks of ECG in a stable manner in a sitting arrangement using non-intrusive sensors. The method utilizes two capacitive ECG sensors (cECGs) to measure ECG, and another two cECGs located adjacent to the sensors for ECG are added to obtain the information on motion. Then, active noise cancellation technique and the motion information are used to reduce motion noise. To verify the proposed method, ECG was measured indoors and during driving, and the accuracy of the detected R peaks was compared. After applying the method, the sum of sensitivity and positive predictivity increased 8.39% on average and 26.26% maximally in the data. Based on the results, it was confirmed that the motion noise was reduced and that more reliable R peak positions could be obtained by the proposed method. The robustness of the new ECG measurement method will elicit benefits to various health care systems that require noninvasive heart rate or heart rate variability measurements.1145Ysciescopu

    Dimerization-Induced Fermi-Surface Reconstruction in IrTe2

    Get PDF
    We report a de Haas-van Alphen (dHvA) oscillation study on IrTe2 single crystals showing complex dimer formations. By comparing the angle dependence of dHvA oscillations with band structure calculations, we show distinct Fermi surface reconstruction induced by a 1/5-type and a 1/8-type dimerizations. This verifies that an intriguing quasi-two-dimensional conducting plane across the layers is induced by dimerization in both cases. A phase transition to the 1/8 phase with higher dimer density reveals that local instabilities associated with intra-and interdimer couplings are the main driving force for complex dimer formations in IrTe2.X11149sciescopu
    corecore