1,583 research outputs found
Effects of current on early stages of focused ion beam nano-machining
In this report we investigate the effects of focused ion beam machining at low doses in the range of 1015–1016 ions cm-2 for currents below 300 pA on Si(100) substrates. The effects of similar doses with currents in the range 10–300 pA were compared. The topography of resulting structures has been characterized using atomic force microscope, while crystallinity of the Si was assessed by means of Raman spectroscopy. These machining parameters allow a controllable preparation of structures either protruding from, or recessed into, the surface with nanometre precision
Variability of ethics education in laboratory medicine training programs: Results of an international survey.
To access publisher's full text version of this article, please click on the hyperlink in Additional Links field or click on the hyperlink at the top of the page marked Files.
This article is open access.Ethical considerations are increasingly important in medicine. We aimed to determine the mode and extent of teaching of ethics in training programs in clinical chemistry and laboratory medicine.We developed an on-line survey of teaching in areas of ethics relevant to laboratory medicine. Reponses were invited from directors of training programs who were recruited via email to leaders of national organizations.The survey was completed by 80 directors from 24 countries who directed 113 programs. The largest numbers of respondents directed postdoctoral training of scientists (42%) or physicians (33%), post-masters degree programs (33%), and PhD programs (29%). Most programs (82%) were 2years or longer in duration. Formal training was offered in research ethics by 39%, medical ethics by 31%, professional ethics by 24% and business ethics by 9%. The number of reported hours of formal training varied widely, e.g., from 0 to >15h/year for research ethics and from 0 to >15h for medical ethics. Ethics training was required and/or tested in 75% of programs that offered training. A majority (54%) of respondents reported plans to add or enhance training in ethics; many indicated a desire for online resources related to ethics, especially resources with self-assessment tools.Formal teaching of ethics is absent from many training programs in clinical chemistry and laboratory medicine, with heterogeneity in the extent and methods of ethics training among the programs that provide the training. A perceived need exists for online training tools, especially tools with self-assessment components
A bio-hybrid tactile sensor incorporating living artificial skin and an impedance sensing array
The development of a bio-hybrid tactile sensor array that incorporates a skin analogue comprised of alginate encapsulated fibroblasts is described. The electrical properties are modulated by mechanical stress induced during contact, and changes are detected by a ten-channel dual-electrode impedance sensing array. By continuously monitoring the impedance of the sensor array at a fixed frequency, whilst normal and tangential loads are applied to the skin surface, transient mechanotransduction has been observed. The results demonstrate the effectiveness and feasibility of the preliminary prototype bio-hybrid tactile sensor
Recommended from our members
Laser and electron deflection from transverse asymmetries in laser-plasma accelerators.
We report on the deflection of laser pulses and accelerated electrons in a laser-plasma accelerator (LPA) by the effects of laser pulse front tilt and transverse density gradients. Asymmetry in the plasma index of refraction leads to laser steering, which can be due to a density gradient or spatiotemporal coupling of the laser pulse. The transverse forces from the skewed plasma wave can also lead to electron deflection relative to the laser. Quantitative models are proposed for both the laser and electron steering, which are confirmed by particle-in-cell simulations. Experiments with the BELLA Petawatt Laser are presented which show controllable 0.1-1 mrad laser and electron beam deflection from laser pulse front tilt. This has potential applications for electron beam pointing control, which is of paramount importance for LPA applications
Recommended from our members
Effects of Verapamil SR and Atenolol on 24-Hour Blood Pressure and Heart Rate in Hypertension Patients with Coronary Artery Disease...
Elevated night-time blood pressure (BP) and heart rate (HR), increased BP and HR variability, and altered diurnal variations of BP and HR (nighttime dipping and morning surge) in patients with systemic hypertension are each associated with increased adverse cardiovascular events. However, there are no reports on the effect of hypertension treatment on these important hemodynamic parameters in the growing population of hypertensive patients with atherosclerotic coronary artery disease (CAD). This was a pre-specified subgroup analysis of the INternational VErapamil SR-Trandolapril STudy (INVEST), which involved 22,576 clinically stable patients aged ≥50 years with hypertension and CAD randomized to either verapamil SR- or atenolol-based hypertension treatment strategies. The subgroup consisted of 117 patients undergoing 24-hour ambulatory monitoring at baseline and after 1 year of treatment. Hourly systolic and diastolic BP (SBP and DBP) decreased after 1 year for both verapamil SR- and atenolol-based treatment strategies compared with baseline (P<0.0001). Atenolol also decreased hourly HR (P<0.0001). Both treatment strategies decreased SBP variability (weighted standard deviation: P = 0.012 and 0.021, respectively). Compared with verapamil SR, atenolol also increased the prevalence of BP and HR night-time dipping among prior non-dippers (BP: OR = 3.37; 95% CI: 1.26 – 8.97; P = 0.015; HR: OR = 4.06; 95% CI: 1.35-12.17;P = 0.012) and blunted HR morning surge (+2.8 vs. +4.5 beats/min/hr; P = 0.019). Both verapamil SR- and especially atenolol-based strategies resulted in favorable changes in ambulatory monitoring parameters that have been previously associated with increased adverse cardiovascular events
Recommended from our members
Effects of Verapamil SR and Atenolol on 24-Hour Blood Pressure and Heart Rate in Hypertension Patients with Coronary Artery Disease...
Elevated night-time blood pressure (BP) and heart rate (HR), increased BP and HR variability, and altered diurnal variations of BP and HR (nighttime dipping and morning surge) in patients with systemic hypertension are each associated with increased adverse cardiovascular events. However, there are no reports on the effect of hypertension treatment on these important hemodynamic parameters in the growing population of hypertensive patients with atherosclerotic coronary artery disease (CAD). This was a pre-specified subgroup analysis of the INternational VErapamil SR-Trandolapril STudy (INVEST), which involved 22,576 clinically stable patients aged ≥50 years with hypertension and CAD randomized to either verapamil SR- or atenolol-based hypertension treatment strategies. The subgroup consisted of 117 patients undergoing 24-hour ambulatory monitoring at baseline and after 1 year of treatment. Hourly systolic and diastolic BP (SBP and DBP) decreased after 1 year for both verapamil SR- and atenolol-based treatment strategies compared with baseline (P<0.0001). Atenolol also decreased hourly HR (P<0.0001). Both treatment strategies decreased SBP variability (weighted standard deviation: P = 0.012 and 0.021, respectively). Compared with verapamil SR, atenolol also increased the prevalence of BP and HR night-time dipping among prior non-dippers (BP: OR = 3.37; 95% CI: 1.26 – 8.97; P = 0.015; HR: OR = 4.06; 95% CI: 1.35-12.17;P = 0.012) and blunted HR morning surge (+2.8 vs. +4.5 beats/min/hr; P = 0.019). Both verapamil SR- and especially atenolol-based strategies resulted in favorable changes in ambulatory monitoring parameters that have been previously associated with increased adverse cardiovascular events
Potent and Broad Inhibition of HIV-1 by a Peptide from the gp41 Heptad Repeat-2 Domain Conjugated to the CXCR4 Amino Terminus.
HIV-1 entry can be inhibited by soluble peptides from the gp41 heptad repeat-2 (HR2) domain that interfere with formation of the 6-helix bundle during fusion. Inhibition has also been seen when these peptides are conjugated to anchoring molecules and over-expressed on the cell surface. We hypothesized that potent anti-HIV activity could be achieved if a 34 amino acid peptide from HR2 (C34) were brought to the site of virus-cell interactions by conjugation to the amino termini of HIV-1 coreceptors CCR5 or CXCR4. C34-conjugated coreceptors were expressed on the surface of T cell lines and primary CD4 T cells, retained the ability to mediate chemotaxis in response to cognate chemokines, and were highly resistant to HIV-1 utilization for entry. Notably, C34-conjugated CCR5 and CXCR4 each exhibited potent and broad inhibition of HIV-1 isolates from diverse clades irrespective of tropism (i.e., each could inhibit R5, X4 and dual-tropic isolates). This inhibition was highly specific and dependent on positioning of the peptide, as HIV-1 infection was poorly inhibited when C34 was conjugated to the amino terminus of CD4. C34-conjugated coreceptors could also inhibit HIV-1 isolates that were resistant to the soluble HR2 peptide inhibitor, enfuvirtide. When introduced into primary cells, CD4 T cells expressing C34-conjugated coreceptors exhibited physiologic responses to T cell activation while inhibiting diverse HIV-1 isolates, and cells containing C34-conjugated CXCR4 expanded during HIV-1 infection in vitro and in a humanized mouse model. Notably, the C34-conjugated peptide exerted greater HIV-1 inhibition when conjugated to CXCR4 than to CCR5. Thus, antiviral effects of HR2 peptides can be specifically directed to the site of viral entry where they provide potent and broad inhibition of HIV-1. This approach to engineer HIV-1 resistance in functional CD4 T cells may provide a novel cell-based therapeutic for controlling HIV infection in humans
- …