43 research outputs found
Evaluation of a learner-designed course for teaching health research skills in Ghana
<p>Abstract</p> <p>Background</p> <p>In developing countries the ability to conduct locally-relevant health research and high quality education are key tools in the fight against poverty. The objective of our study was to evaluate the effectiveness of a novel UK accredited, learner-designed research skills course delivered in a teaching hospital in Ghana.</p> <p>Methods</p> <p>Study participants were 15 mixed speciality health professionals from Komfo Anokye Teaching Hospital, Kumasi, Ghana. Effectiveness measures included process, content and outcome indicators to evaluate changes in learners' confidence and competence in research, and assessment of the impact of the course on changing research-related thinking and behaviour. Results were verified using two independent methods.</p> <p>Results</p> <p>14/15 learners gained research competence assessed against UK Quality Assurance Agency criteria. After the course there was a 36% increase in the groups' positive responses to statements concerning confidence in research-related attitudes, intentions and actions. The greatest improvement (45% increase) was in learners' actions, which focused on strengthening institutional research capacity. 79% of paired before/after responses indicated positive changes in individual learners' research-related attitudes (n = 53), 81% in intention (n = 52) and 85% in action (n = 52). The course had increased learners' confidence to start and manage research, and enhanced life-long skills such as reflective practice and self-confidence. Doing their own research within the work environment, reflecting on personal research experiences and utilising peer support and pooled knowledge were critical elements that promoted learning.</p> <p>Conclusion</p> <p>Learners in Ghana were able to design and undertake a novel course that developed individual and institutional research capacity and met international standards. Learning by doing and a supportive peer community at work were critical elements in promoting learning in this environment where tutors were scarce. Our study provides a model for delivering and evaluating innovative educational interventions in developing countries to assess whether they meet external quality criteria and achieve their objectives.</p
Non-motor predictors of 36-month quality of life after subthalamic stimulation in Parkinson disease
AbstractTo identify predictors of 36-month follow-up quality of life (QoL) outcome after bilateral subthalamic nucleus deep brain stimulation (STN-DBS) in Parkinsonâs disease (PD). In this ongoing, prospective, multicenter international study (Cologne, Manchester, London) including 73 patients undergoing STN-DBS, we assessed the following scales preoperatively and at 6-month and 36-month follow-up: PD Questionnaire-8 (PDQ-8), NMSScale (NMSS), Scales for Outcomes in PD (SCOPA)-motor examination, -activities of daily living, and -complications, and levodopa equivalent daily dose (LEDD). We analyzed factors associated with QoL improvement at 36-month follow-up based on (1) correlations between baseline test scores and QoL improvement, (2) step-wise linear regressions with baseline test scores as independent and QoL improvement as dependent variables, (3) logistic regressions and receiver operating characteristic curves using a dichotomized variable âQoL respondersâ/ânon-respondersâ. At both follow-ups, NMSS total score, SCOPA-motor examination, and -complications improved and LEDD was reduced significantly. PDQ-8 improved at 6-month follow-up with subsequent decrements in gains at 36-month follow-up when 61.6% of patients were categorized as âQoL non-respondersâ. Correlations, linear, and logistic regression analyses found greater PDQ-8 improvements in patients with younger age, worse PDQ-8, and worse specific NMS at baseline, such as âdifficulties experiencing pleasureâ and âproblems sustaining concentrationâ. Baseline SCOPA scores were not associated with PDQ-8 changes. Our results provide evidence that 36-month QoL changes depend on baseline neuropsychological and neuropsychiatric non-motor symptoms burden. These findings highlight the need for an assessment of a wide range of non-motor and motor symptoms when advising and selecting individuals for DBS therapy
Assessment of primary prevention patients receiving an ICD - Systematic evaluation of ATP: APPRAISE ATP
Background: The value of antitachycardia pacing (ATP) in the overall cohort of primary prevention patients who receive implantable cardioverter-defibrillators (ICDs) remains uncertain. ATP success reported in prior trials potentially included a large number of patients receiving unnecessary ATP for arrhythmias that may have self-terminated owing to the prematurity of the intervention. Although some patients derive benefit from initial ATP in terminating rapid ventricular arrhythmias and thereby preventing shocks, there are limited data allowing us to identify those patients
Objective: The purpose of APPRAISE ATP is to understand the role of ATP in primary prevention patients currently indicated for ICD therapy in a large prospective randomized controlled trial with modern programming parameters.
Methods: The study is a global, prospective, randomized, multicenter clinical trial conducted at up to 150 sites globally, enrolling approximately 2600 subjects The primary endpoint of the trial is time to first all-cause shock in a 2-arm study with an equivalent study design in which the incidence of all-cause shocks will be compared between primary prevention subjects programmed with shocks only vs subjects programmed to standard therapy (ATP and shock).
Results: An Electrogram and Device Interrogation Core Laboratory will review interrogation data to determine primary endpoints that occur in APPRAISE ATP. Their decisions are based on independent physician review of the data from device interrogation.
Conclusion: The ultimate purpose of the study is to aid clinicians in the selection of ICD technologies based on hard endpoint evidence across the spectrum of indications for primary prevention implantation
Comparative study of acute and mid-term complications with leadless and transvenous cardiac pacemakers
BACKGROUND: Leadless cardiac pacemakers (LCPs) aim to mitigate lead- and pocket-related complications seen with transvenous pacemakers (TVPs).
OBJECTIVE: The purpose of this study was to compare complications between the LCP cohort from the LEADLESS Pacemaker IDE Study (Leadless II) trial and a propensity score-matched real-world TVP cohort.
METHODS: The multicenter LEADLESS II trial evaluated the safety and efficacy of the Nanostim LCP (Abbott, Abbott Park, IL) using structured follow-up, with serious adverse device effects independently adjudicated. TVP data were obtained from Truven Health MarketScan claims databases for patients implanted with single-chamber TVPs between April 1, 2010 and March 31, 2014 and more than 1 year of preimplant enrollment data. Comorbidities and complications were identified via International Classification of Diseases, Ninth Revision and Current Procedural Terminology codes. Short-term (â€1 months) and mid-term (\u3e1-18 months) complications were compared between the LCP cohort and a propensity score-matched subset of the TVP cohort.
RESULTS: Among 718 patients with LCPs (mean age 75.6 ± 11.9 years; 62% men) and 1436 patients with TVPs (mean age 76.1 ± 12.3 years; 63% men), patients with LCPs experienced fewer complications (hazard ratio 0.44; 95% confidence interval 0.32-0.60; P \u3c .001), including short-term (5.8% vs 9.4%; P = .01) and mid-term (0.56% vs 4.9%; P \u3c .001) events. In the short-term time frame, patients with LCPs had more pericardial effusions (1.53% vs 0.35%; P = .005); similar rates of vascular events (1.11% vs 0.42%; P = .085), dislodgments (0.97% vs 1.39%; P = .54), and generator complications (0.70% vs 0.28%; P = .17); and no thoracic trauma compared to patients with TVPs (rate of thoracic trauma 3.27%). In short- and mid-term time frames, TVP events absent from the LCP group included lead-related, pocket-related, and infectious complications.
CONCLUSION: Patients with LCPs experienced fewer overall short- and mid-term complications, including infectious and lead- and pocket-related events, but more pericardial effusions, which were uncommon but serious
Preclinical safety and electrical performance of novel atrial leadless pacemaker with dual-helix fixation
Background: Complications associated with transvenous pacemakers, specifically those involving the lead or subcutaneous pocket, may be avoided with leadless pacemakers (LPs). The safety and efficacy of single-chamber right ventricular LPs have been demonstrated, but their right atrium (RA) use poses new design constraints. Objectives: The purpose of this study was to evaluate the implant success, electrical performance, and safety of a novel RA LP design in benchtop and preclinical studies. Methods: A new LP was designed with a dual-helix fixation mechanism specific to the RA anatomy. A 12-week preclinical ovine study was conducted to evaluate implant success, electrical performance, mechanical stability, and safety in vivo, with supporting benchtop measurements to quantify the mechanical forces needed for device retrieval and dislodgment. Results: LPs were successfully implanted in all 10 ovine subjects with no complications. The pacing capture threshold improved significantly over time from implant to week 12 (1.1 ± 0.7 V vs 0.4 ± 0.2 V, P =.008). Sensing amplitudes and pacing impedances were stable from implant to week 12 (4.8 ± 1.8 mV vs 6.0 ± 1.9 mV, P =.160; and 393 ± 77 Ω vs 398 ± 65 Ω, P =.922, respectively). Gross pathology and microscopic histology revealed no adverse interactions and no evidence of device dislodgment or clinically significant myocardial perforation. Benchtop ex vivo porcine atrial tissue measurements revealed greater pull forces required to dislodge the LP vs transvenous active fixation lead (0.42 ± 0.18 lbf vs 0.29 ± 0.08 lbf, P =.020), and greater rotational forces required for deliberate extraction (0.28 ± 0.04 lbf vs 0.14 ± 0.07 lbf, P <.001). Conclusion: The novel atrial LP demonstrated successful implantation, with acceptable electrical performance, mechanical stability, and safety in a 12-week preclinical study
Design and rationale of the MODULAR ATP global clinical trial : A novel intercommunicative leadless pacing system and the subcutaneous implantable cardioverter-defibrillator
BACKGROUND: The subcutaneous implantable cardioverter-defibrillator (S-ICD) has demonstrated safety and efficacy for the treatment of malignant ventricular arrhythmias. However, a limitation of the S-ICD lies in the inability to either pace-terminate ventricular tachycardia or provide prolonged bradycardia pacing support. OBJECTIVE: The rationale and design of a prospective, single-arm, multinational trial of an intercommunicative leadless pacing system integrated with the S-ICD will be presented. METHODS: A technical description of the modular cardiac rhythm management (mCRM) system (EMPOWER leadless pacemaker and EMBLEM S-ICD) and the implantation procedure is provided. MODULAR ATP (Effectiveness of the EMPOWER (TM) Modular Pacing System and EMBLEM (TM) Subcutaneous ICD to Communicate Antitachycardia Pacing) is amulticenter, international trial enrolling up to 300 patients at risk of sudden cardiac death at up to 60 centers trial design. The safety endpoint of freedom from major complications related to the mCRM system or implantation procedure at 6 months and 2 years are significantly higher than 86% and 81%, respectively, and all-cause survival is significantly.85% at 2 years. RESULTS: Efficacy endpoints are that at 6 months mCRM communication success is significantly higher than 88% and the percentage of subjects with low and stable thresholds is significantly higher than 80%. Substudies to evaluate rate-responsive features and performance of the pacing module are also described. CONCLUSION: The MODULAR ATP global clinical trial will prospectively test the safety and efficacy of the first intercommunicating leadless pacing system with the S-ICD. This trial will allow for robust validation of device-device communication, pacing performance, rate responsiveness, and system safety