13 research outputs found
Recommended from our members
Identification of structural features of condensed tannins that affect protein aggregation
A diverse panel of condensed tannins was used to resolve the confounding effects of size and subunit composition seen previously in tannin-protein interactions. Turbidimetry revealed that size in terms of mean degree of polymerisation (mDP) or average molecular weight (amw) was the most important tannin parameter. The smallest tannin with the relatively largest effect on protein aggregation had an mDP of ~7. The average size was significantly correlated with aggregation of bovine serum albumin, BSA (mDP: r=-0.916; amw: r=-0.925; p<0.01; df=27), and gelatin (mDP: r=-0.961; amw: r=-0.981; p<0.01; df=12). The procyanidin/prodelphinidin and cis-/trans-flavan-3-ol ratios gave no significant correlations. Tryptophan fluorescence quenching indicated that procyanidins and cis-flavan-3-ol units contributed most to the tannin interactions on the BSA surface and in the hydrophobic binding pocket (r=0.677; p<0.05; df=9 and r=0.887; p<0.01; df=9, respectively). Circular dichroism revealed that higher proportions of prodelphinidins decreased the apparent α-helix content (r=-0.941; p<0.01; df=5) and increased the apparent β-sheet content (r=0.916; p<0.05; df=5) of BSA
Recommended from our members
1H–13C HSQC NMR Spectroscopy for Estimating Procyanidin/Prodelphinidin and cis/trans-Flavan-3-ol Ratios of Condensed Tannin Samples: Correlation with Thiolysis
Studies with a diverse array of 22 purified condensed tannin (CT) samples from nine plant species demonstrated that procyanidin/prodelphinidin (PC/PD) and cis/trans-flavan-3-ol ratios can be appraised by 1H–13C HSQC NMR spectroscopy. The method was developed from samples containing 44–∼100% CT, PC/PD ratios ranging from 0/100 to 99/1, and cis/trans ratios ranging from 58/42 to 95/5 as determined by thiolysis with benzyl mercaptan. Integration of cross-peak contours of H/C-6′ signals from PC and of H/C-2′,6′ signals from PD yielded nuclei-adjusted estimates that were highly correlated with PC/PD ratios obtained by thiolysis (R2 = 0.99). cis/trans-Flavan-3-ol ratios, obtained by integration of the respective H/C-4 cross-peak contours, were also related to determinations made by thiolysis (R2 = 0.89). Overall, 1H–13C HSQC NMR spectroscopy appears to be a viable alternative to thiolysis for estimating PC/PD and cis/trans ratios of CT if precautions are taken to avoid integration of cross-peak contours of contaminants
Single-row vs. double-row arthroscopic rotator cuff repair: clinical and 3 Tesla MR arthrography results
<p>Abstract</p> <p>Background</p> <p>Arthroscopic rotator cuff repair has become popular in the last few years because it avoids large skin incisions and deltoid detachment and dysfunction. Earlier arthroscopic single-row (SR) repair methods achieved only partial restoration of the original footprint of the tendons of the rotator cuff, while double-row (DR) repair methods presented many biomechanical advantages and higher rates of tendon-to-bone healing. However, DR repair failed to demonstrate better clinical results than SR repair in clinical trials. MR imaging at 3 Tesla, especially with intra-articular contrast medium (MRA), showed a better diagnostic performance than 1.5 Tesla in the musculoskeletal setting. The objective of this study was to retrospectively evaluate the clinical and 3 Tesla MRA results in two groups of patients operated on for a medium-sized full-thickness rotator cuff tear with two different techniques.</p> <p>Methods</p> <p>The first group consisted of 20 patients operated on with the SR technique; the second group consisted of 20 patients operated on with the DR technique. All patients were evaluated at a minimum of 3 years after surgery. The primary end point was the re-tear rate at 3 Tesla MRA. The secondary end points were the Constant-Murley Scale (CMS), the Simple Shoulder Test (SST) scores, surgical time and implant expense.</p> <p>Results</p> <p>The mean follow-up was 40 months in the SR group and 38.9 months in the DR group. The mean postoperative CMS was 70 in the SR group and 68 in the DR group. The mean SST score was 9.4 in the SR group and 10.1 in the DR group. The re-tear rate was 60% in the SR group and 25% in the DR group. Leakage of the contrast medium was observed in all patients.</p> <p>Conclusions</p> <p>To the best of our knowledge, this is the first report on 3 Tesla MRA in the evaluation of two different techniques of rotator cuff repair. DR repair resulted in a statistically significant lower re-tear rate, with longer surgical time and higher implant expense, despite no difference in clinical outcomes. We think that leakage of the contrast medium is due to an incomplete tendon-to-bone sealing, which is not a re-tear. This phenomenon could have important medicolegal implications.</p> <p>Level of evidence III. Treatment study: Case–control study.</p