Building integrated solar thermal collectors for heating & cooling applications
International Energy Agency Solar Heating & Cooling (IEA SHC) programme states the fact that space/water heating and cooling demand account for over 75% of the energy consumed in single and multi-family homes. Solar energy technology can meet up to 100% of this demand depending on the size of the system, storage capacity, the heat load and the region’s climate.
Solar thermal collectors are particular type of heat extracting devices that convert solar radiation into thermal energy through a transport medium or flowing fluid. Although hybrid PV/T or thermal-alone systems offer some advantages to improve the solar heat utilisation, there are a few technical challenges found in these systems in practice that prevented wide-scale applications. These technical drawbacks include being expensive to make and install, inability of switching already-built photovoltaic (PV) systems into PV/T systems, architectural design etc. The aims of this project, therefore, were to investigate roof integrated solar thermal roof collectors that properly blend into surrounding thus avoiding ‘add on’ appearance and having a dual function (heat absorption and roofing). Another objective was to address the inherent technical pitfalls and practical limitations of conventional solar thermal collectors by bringing unique, inexpensive, maintenance free and easily adaptable solutions. Thus, in this innovative research, unique and simple building integrated solar thermal roof collectors have been developed for heating & cooling applications. The roof systems which mainly based on low cost and structurally unique polyethylene heat exchanger are relatively cost effective, competitive and developed by primarily exploiting components and techniques widely available on the market.
The following objectives have been independently achieved via evaluating three aspects of investigations as following:
• Investigation on the performance of poly heat exchanger underneath PV units
• Investigation on the performance of a Building Integrated PV/T Roof ‘Invisible’ Collector combined with a liquid desiccant enhanced indirect evaporative cooling system
• Investigation on the build-up and performance test of a novel ‘Sandwich’ solar thermal roof for heat pump operation
These works have been assessed by means of computer simulation, laboratory and field experimental work and have been demonstrated adequately. The key findings from the study confirm the potential of the examined technology, and elucidate the specific conclusions for the practice of such systems.
The analysis showed that water temperature within the poly heat exchanger loop underneath PV units could reach up to 36°C and the system would achieve up to 20.25% overall thermal efficiency. Techno-economic analysis was carried out by applying the Life Cycle Cost (LCC) method. Evaluations showed that the estimated annual energy savings of the overall system was 10.3 MWh/year and the cost of power generation was found to be £0.0622 per kWh.
The heat exchanger loop was coupled with a liquid desiccant enhanced indirect evaporative cooling unit and experimental results indicated that the proposed system could supply about 3 kW of heating and 5.2 kW of cooling power.
Lastly, the results from test of a novel solar thermal collector for heat pump operation presented that the difference in water temperature could reach up to 18°C while maximum thermal efficiency found to be 26%. Coefficient Performance of the heat pump (COPHP) and overall system (COPSYS) averages were attained as COPHP=3.01 and COPSYS=2.29, respectively. An economic analysis pointed a minimum payback period of about 3 years for the system
Building integrated solar thermal collectors for heating & cooling applications
International Energy Agency Solar Heating & Cooling (IEA SHC) programme states the fact that space/water heating and cooling demand account for over 75% of the energy consumed in single and multi-family homes. Solar energy technology can meet up to 100% of this demand depending on the size of the system, storage capacity, the heat load and the region’s climate.
Solar thermal collectors are particular type of heat extracting devices that convert solar radiation into thermal energy through a transport medium or flowing fluid. Although hybrid PV/T or thermal-alone systems offer some advantages to improve the solar heat utilisation, there are a few technical challenges found in these systems in practice that prevented wide-scale applications. These technical drawbacks include being expensive to make and install, inability of switching already-built photovoltaic (PV) systems into PV/T systems, architectural design etc. The aims of this project, therefore, were to investigate roof integrated solar thermal roof collectors that properly blend into surrounding thus avoiding ‘add on’ appearance and having a dual function (heat absorption and roofing). Another objective was to address the inherent technical pitfalls and practical limitations of conventional solar thermal collectors by bringing unique, inexpensive, maintenance free and easily adaptable solutions. Thus, in this innovative research, unique and simple building integrated solar thermal roof collectors have been developed for heating & cooling applications. The roof systems which mainly based on low cost and structurally unique polyethylene heat exchanger are relatively cost effective, competitive and developed by primarily exploiting components and techniques widely available on the market.
The following objectives have been independently achieved via evaluating three aspects of investigations as following:
• Investigation on the performance of poly heat exchanger underneath PV units
• Investigation on the performance of a Building Integrated PV/T Roof ‘Invisible’ Collector combined with a liquid desiccant enhanced indirect evaporative cooling system
• Investigation on the build-up and performance test of a novel ‘Sandwich’ solar thermal roof for heat pump operation
These works have been assessed by means of computer simulation, laboratory and field experimental work and have been demonstrated adequately. The key findings from the study confirm the potential of the examined technology, and elucidate the specific conclusions for the practice of such systems.
The analysis showed that water temperature within the poly heat exchanger loop underneath PV units could reach up to 36°C and the system would achieve up to 20.25% overall thermal efficiency. Techno-economic analysis was carried out by applying the Life Cycle Cost (LCC) method. Evaluations showed that the estimated annual energy savings of the overall system was 10.3 MWh/year and the cost of power generation was found to be £0.0622 per kWh.
The heat exchanger loop was coupled with a liquid desiccant enhanced indirect evaporative cooling unit and experimental results indicated that the proposed system could supply about 3 kW of heating and 5.2 kW of cooling power.
Lastly, the results from test of a novel solar thermal collector for heat pump operation presented that the difference in water temperature could reach up to 18°C while maximum thermal efficiency found to be 26%. Coefficient Performance of the heat pump (COPHP) and overall system (COPSYS) averages were attained as COPHP=3.01 and COPSYS=2.29, respectively. An economic analysis pointed a minimum payback period of about 3 years for the system
Build-up and performance test of a novel solar thermal roof for heat pump operation
Global increase in energy demand and fossil fuel prices loaded ever-increasing pressure on identifying and implementing new means to utilise clean and efficient energy resources. Due to the environmental benefits, technical and economic possibilities of Solar-Assisted Heat Pump Systems, there has been a growing interest for such hybrid systems with a variety of system configurations for various climates. International Energy Agency Task 44 of the Solar Heating and Cooling Programme has recently started working on finding methods to most effectively use solar heat pump systems for residential use. In the present study, a novel solar thermal roof collector was developed by primarily exploiting components and techniques widely available on the market and coupled with a commercial heat pump unit. The proposed indirect series Solar-assisted Heat Pump system was experimentally tested and system performance was investigated. Yet, the analysis based on indoor and outdoor testing predominantly focuses on the solar thermal roof collector. A detailed thermal model was developed to describe the system operation. Also, a computer model was set up by using Engineering Equation Solver to carry out the numerical computations of the governing equations. Analyses show that the difference in water temperature could reach up to 18°C while maximum thermal efficiency found to be 26%. Data processing of the series covering the test period represents that Coefficient Performance of the heat pump (COPHP) and overall system (COPSYS) averages were attained as COPHP = 3.01 and COPSYS = 2.29, respectively. An economic analysis points a minimum payback period of about three years for the system