77 research outputs found

    The role of hemodialysis machines dedication in reducing Hepatitis C transmission in the dialysis setting in Iran: A multicenter prospective interventional study

    Get PDF
    BACKGROUND: Hepatitis C virus (HCV) infection is a significant problem among patients undergoing maintenance hemodialysis (HD). We conducted a prospective multi-center study to evaluate the effect of dialysis machine separation on the spread of HCV infection. METHODS: Twelve randomly selected dialysis centers in Tehran, Iran were randomly divided into two groups; those using dedicated machines (D) for HCV infected individuals and those using non-dedicated HD machines (ND). 593 HD cases including 51 HCV positive (RT-PCR) cases and 542 HCV negative patients were enrolled in this study. The prevalence of HCV infection in the D group was 10.1% (range: 4.6%– 13.2%) and it was 7.1% (range: 4.2%–16.8%) in the ND group. During the study conduction 5 new HCV positive cases and 169 new HCV negative cases were added. In the D group, PCR positive patients were dialyzed on dedicated machines. In the ND group all patients shared the same machines. RESULTS: In the first follow-up period, the incidence of HCV infection was 1.6% and 4.7% in the D and ND group respectively (p = 0.05). In the second follow-up period, the incidence of HCV infection was 1.3% in the D group and 5.7% in the ND group (p < 0.05). CONCLUSIONS: In this study the incidence of HCV in HD patients decreased by the use of dedicated HD machines for HCV infected patients. Additional studies may help to clarify the role of machine dedication in conjunction with application of universal precautions in reducing HCV transmission

    UDP-glucuronosyltransferase UGT1A7 genetic polymorphisms in hepatocellular carcinoma: a differential impact according to seropositivity of HBV or HCV markers?

    Get PDF
    <p>Abstract</p> <p>Background:</p> <p>We conducted a case-control study to evaluate the role of UDP-glucuronosyltransferase 1A7 (UGT1A7) polymorphisms in the onset of hepatocellular carcinoma (HCC).</p> <p>Methods:</p> <p>The study included 165 patients with HCC, 134 with cirrhosis and 142 controls without liver disease, matched for age and hospital. All were men younger than 75 years. HCC and cirrhosis patients were stratified according to time since cirrhosis diagnosis.</p> <p>Results:</p> <p>We found a positive association between the UGT1A7*3/*3 genotype and HCC when the comparison was restricted to patients whose disease was of viral origin [OR = 3.4 (0.3–45)] but a negative association when it included only alcoholic patients [OR = 0.1 (0.02–0.6), p = 0.01].</p> <p>Conclusion:</p> <p>Our study shows that UGT1A7 may play a role in hepatocellular carcinogenesis and that this role may differ according to the primary cause of the cirrhosis.</p

    Hepatitis C virus-specific cellular immune responses in individuals with no evidence of infection

    Get PDF
    The detection of hepatitis C virus (HCV)-specific T cell responses in HCV-uninfected, presumably unexposed, subjects could be due to an underestimation of the frequency of spontaneously resolving infections, as most acute HCV infections are clinically silent. To address this hypothesis, HCV-specific cellular immune responses were characterized, in individuals negative for an HCV PCR assay and humoral response, with (n = 32) or without (n = 33) risk of exposure to HCV. Uninfected volunteers (n = 20) with a chronically HCV-infected partner were included as positive controls for potential exposure to HCV and HCV infection, respectively. HCV-specific T cell responses in freshly isolated peripheral blood mononuclear cells were studied ex vivo by ELISPOT and CFSE-based proliferation assays using panels of HCV Core and NS3-derived peptides. A pool of unrelated peptides was used as a negative control, and a peptide mix of human cytomegalovirus, Epstein-Bar virus and Influenza virus as a positive control. Overall, 20% of presumably HCV-uninfected subject tested had detectable T-cell responses to the virus, a rate much higher than previous estimates of HCV prevalence in developed countries. This result would be consistent with unapparent primary HCV infections that either cleared spontaneously or remained undetected by conventional serological assays

    An operative case of hepatic pseudolymphoma difficult to differentiate from primary hepatic marginal zone B-cell lymphoma of mucosa-associated lymphoid tissue

    Get PDF
    Hepatic pseudolymphoma (HPL) and primary hepatic marginal zone B cell lymphoma of mucosa-associated lymphoid tissue (MALT lymphoma) are rare diseases and the differential diagnosis between these two entities is sometimes difficult. We herein report a 56-year-old Japanese woman who was pointed out to have a space occupying lesion in the left lateral segment of the liver. Hepatitis viral-associated antigen/antibody was negative and liver function tests including lactic dehydrogenase, peripheral blood count, tumor markers and soluble interleukin-2 receptor were all within normal limit. Imaging study using computed tomography and magnetic resonance imaging were not typical for hepatocellular carcinoma, cholangiocarcinoma, or other metastatic cancer. Fluorodeoxyglucose-positron emission tomography examination integrated with computed tomography scanning showed high standardized uptake value in the solitary lesion in the liver. Under a diagnosis of primary liver neoplasm, laparoscopic-assisted lateral segmentectomy was performed. Liver tumor of maximal 1.0 cm in diameter was consisted of aggregation of lymphocytes of predominantly B-cell, containing multiple lymphocyte follicles positive for CD10 and bcl-2, consistent with a diagnosis of HPL rather than MALT lymphoma, although a definitive differentiation was pending. The background liver showed non-alcoholic fatty liver disease/early non-alcoholic steatohepatitis. The patient is currently doing well with no sign of relapse 13 months after the surgery. Since the accurate diagnosis is difficult, laparoscopic approach would provide a reasonable procedure of diagnostic and therapeutic advantage with minimal invasiveness for patients. Considering that the real nature of this entity remains unclear, vigilant follow-up of patient is essential

    Quality Indicators for Colonoscopy Procedures: A Prospective Multicentre Method for Endoscopy Units

    Get PDF
    BACKGROUND AND AIMS: Healthcare professionals are required to conduct quality control of endoscopy procedures, and yet there is no standardised method for assessing quality. The topic of the present study was to validate the applicability of the procedure in daily practice, giving physicians the ability to define areas for continuous quality improvement. METHODS: In ten endoscopy units in France, 200 patients per centre undergoing colonoscopy were enrolled in the study. An evaluation was carried out based on a prospectively developed checklist of 10 quality-control indicators including five dependent upon and five independent of the colonoscopy procedure. RESULTS: Of the 2000 procedures, 30% were done at general hospitals, 20% at university hospitals, and 50% in private practices. The colonoscopies were carried out for a valid indication for 95.9% (range 92.5-100). Colon preparation was insufficient in 3.7% (range 1-10.5). Colonoscopies were successful in 95.3% (range 81-99). Adenoma detection rate was 0.31 (range 0.17-0.45) in successful colonoscopies. CONCLUSION: This tool for evaluating the quality of colonoscopy procedures in healthcare units is based on standard endoscopy and patient criteria. It is an easy and feasible procedure giving the ability to detect suboptimal practice and differences between endoscopy-units. It will enable individual units to assess the quality of their colonoscopy techniques

    Pegylated Interferon and Ribavirin Dosing Strategies to Enhance Sustained Virologic Response

    Get PDF
    Hepatitis C virus (HCV) affects about 170 million people worldwide and is the most common chronic blood borne infection in the United States. Since the advent of blood screening protocols in the early 1990s, injection drug use has become the leading cause of infection. Hepatitis C can have both hepatic and nonhepatic manifestations of infection. Hepatic manifestations include hepatic fibrosis, cirrhosis, liver cancer, and liver failure. The standard treatment for chronic HCV is combination therapy with pegylated interferon-α and ribavirin. Although pegylated interferon and ribavirin has been used against HCV for close to a decade, advances in therapy have centered on doses and treatment durations. There has been increasing interest in applying on-treatment response or viral kinetics to predict antiviral response rates and shape therapeutic intervention. Protease inhibitors are a promising adjuvant to combination therapy, but their efficacy and safety are still under investigation

    EVOTECH® endoscope cleaner and reprocessor (ECR) simulated-use and clinical-use evaluation of cleaning efficacy

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>The objective of this study was to perform simulated-use testing as well as a clinical study to assess the efficacy of the EVOTECH<sup>® </sup>Endoscope Cleaner and Reprocessor (ECR) cleaning for flexible colonoscopes, duodenoscopes, gastroscopes and bronchoscopes. The main aim was to determine if the cleaning achieved using the ECR was at least equivalent to that achieved using optimal manual cleaning.</p> <p>Methods</p> <p>Simulated-use testing consisted of inoculating all scope channels and two surface sites with Artificial Test Soil (ATS) containing 10<sup>8 </sup>cfu/mL of <it>Enterococcus faecalis, Pseudomonas aeruginosa </it>and <it>Candida albicans</it>. Duodenoscopes, colonoscopes, and bronchoscopes (all Olympus endoscopes) were included in the simulated use testing. Each endoscope type was tested in triplicate and all channels and two surface sites were sampled for each scope. The clinical study evaluated patient-used duodenoscopes, bronchoscopes, colonoscopes, and gastroscopes (scopes used for emergency procedures were excluded) that had only a bedside flush prior to being processed in the ECR (i.e. no manual cleaning). There were 10 to 15 endoscopes evaluated post-cleaning and to ensure the entire ECR cycle was effective, 5 endoscopes were evaluated post-cleaning and post-high level disinfection. All channels and two external surface locations were sampled to evaluate the residual organic and microbial load. Effective cleaning of endoscope surfaces and channels was deemed to have been achieved if there was < 6.4 μg/cm<sup>2 </sup>of residual protein, < 1.8 μg/cm<sup>2 </sup>of residual hemoglobin and < 4 Log<sub>10 </sub>viable bacteria/cm<sup>2</sup>. Published data indicate that routine manual cleaning can achieve these endpoints so the ECR cleaning efficacy must meet or exceed these to establish that the ECR cleaning cycle could replace manual cleaning</p> <p>Results</p> <p>In the clinical study 75 patient-used scopes were evaluated post cleaning and 98.8% of surfaces and 99.7% of lumens met or surpassed the cleaning endpoints set for protein, hemoglobin and bioburden residuals. In the simulated-use study 100% of the Olympus colonoscopes, duodenoscopes and bronchoscopes evaluated met or surpassed the cleaning endpoints set for protein, and bioburden residuals (hemoglobin was not evaluated).</p> <p>Conclusions</p> <p>The ECR cleaning cycle provides an effective automated approach that ensures surfaces and channels of flexible endoscopes are adequately cleaned after having only a bedside flush but no manual cleaning. It is crucial to note that endoscopes used for emergency procedures or where reprocessing is delayed for more than one hour MUST still be manually cleaned prior to placing them in the ECR.</p
    corecore