178 research outputs found

    Senior Recital: Brandon Taylor Austin, trumpet

    Get PDF
    This recital is presented in partial fulfillment of requirements for the degree Bachelor of Music in Performance. Mr. Austin studies trumpet with Douglas Lindsey.https://digitalcommons.kennesaw.edu/musicprograms/1131/thumbnail.jp

    Roll-Call Vote Selection: Implications for the Study of Legislative Politics

    Get PDF
    Roll-call votes provide scholars with the opportunity to measure many quantities of interest. However, the usefulness of the roll-call sample depends on the population it is intended to represent. After laying out why understanding the sample properties of the roll-call record is important, we catalogue voting procedures for 145 legislative chambers, finding that roll calls are typically discretionary. We then consider two arguments for discounting the potential problem: (a) roll calls are ubiquitous, especially where the threshold for invoking them is low or (b) the strategic incentives behind requests are sufficiently benign so as to generate representative samples. We address the first defense with novel empirical evidence regarding roll-call prevalence and the second with an original formal model of the position-taking argument for roll-call vote requests. Both our empirical and theoretical results confirm that inattention to vote method selection should broadly be considered an issue for the study of legislative behavior

    Functional association of Sun1 with nuclear pore complexes

    Get PDF
    Sun1 and 2 are A-type lamin-binding proteins that, in association with nesprins, form a link between the inner nuclear membranes (INMs) and outer nuclear membranes of mammalian nuclear envelopes. Both immunofluorescence and immunoelectron microscopy reveal that Sun1 but not Sun2 is intimately associated with nuclear pore complexes (NPCs). Topological analyses indicate that Sun1 is a type II integral protein of the INM. Localization of Sun1 to the INM is defined by at least two discrete regions within its nucleoplasmic domain. However, association with NPCs is dependent on the synergy of both nucleoplasmic and lumenal domains. Cells that are either depleted of Sun1 by RNA interference or that overexpress dominant-negative Sun1 fragments exhibit clustering of NPCs. The implication is that Sun1 represents an important determinant of NPC distribution across the nuclear surface

    A Comparison of Temperatures Inside Protective Headgear With Indicators of Physiological Strain and Core Temperatures During Exercise in a Hot Environment

    Get PDF
    Introduction: Non-invasive temperature monitoring with a sensor mounted inside protective headgear such as a football or military helmet or a construction hardhat may be an effective method of detecting temperatures that are indicative of increased risk of heat illness. Hothead Technologies has developed a system for providing temperature information to medical personnel responsible for the health of the individual. Purpose: The purposes of this study were to establish the relationship between in-hardhat temperature (Tih) readings, markers of physiological strain and perceptual responses, and to determine the differences between the in-helmet temperature readings and core temperature (Tc) as measured by rectal (Tre) and esophageal (Tes) probes. Methods: Thirty males (age, 24.57 ± 4.32 years; height 180.51 ±7.06 cm; body mass, 81.06 ±9.35 kg; percent body fat, 13.76 ±5.11; VO2max, 46.84 ± 7.10 mL/Kg/min) completed two experimental trials separated by a minimum of one week: a continuous submaximal exercise (CSE) condition and a series of high intensity 30-second sprints (HIE) with a one-minute rest period between each sprint. Exercise in both conditions was carried out in a 36o C environment with a relative humidity of 40% while wearing a standard construction hardhat with a sensor mounted in the forehead area of the head strap, and continued until one of the following two criteria was met: the subject voluntarily terminated the session, or the subject’s Tc reached 39.5oC. Temperatures, heart rate, cardiorespiratory, and perceptual responses were monitored throughout, and balance error scoring system (BESS) and mental function tests were conducted before and after exercise. A physiological strain index (PSI) was calculated from Tc and HR. Results: CV- Calculated from final temp. Conclusion: The general agreement between the Tih and other temperature measures along with the consistency as indicated by the low coefficient of variation in the recordings of the Tih sensors at the point of termination suggest that this device may have application as a warning system for impending heat-related problems

    Uniform longitudinal beam profiles in the Fermilab Recycler using adaptive rf correction

    Get PDF
    The Fermilab Recycler Ring is a permanent magnet based 8 GeV anti-proton storage ring. A wideband RF system, driven with ARB's (ARBitrary waveform generators), allows the system to produce programmable barrier waveforms. Beam current profile distortion was observed, its origin verified both experimentally and theoretically, and an FPGA-based correction system was designed, tested and implemented to level the bunch profile

    Absorption Coefficient (ABSCO) Tables for the Orbiting Carbon Observatories: Version 5.1

    Get PDF
    The accuracy of atmospheric trace gas retrievals depends directly on the accuracy of the molecular absorption model used within the retrieval algorithm. For remote sensing of well-mixed gases, such as carbon dioxide (CO₂), where the atmospheric variability is small compared to the background, the quality of the molecular absorption model is key. Recent updates to oxygen (O₂) absorption coefficients (ABSCO) for the 0.76 μm A-band and the water vapor (H₂O) continuum model within the 1.6 μm and 2.06 μm CO₂ bands used within the Orbiting Carbon Observatory (OCO-2 and OCO-3) algorithm are described here. Updates in the O₂ A-band involve the inclusion of new laboratory measurements within multispectrum fits to improve relative consistency between O₂ line shapes and collision-induced absorption (CIA). The H₂O continuum model has been updated to MTCKD v3.2, which has benefited from information from a range of laboratory studies relative to the model utilized in the previous ABSCO version. Impacts of these spectroscopy updates have been evaluated against ground-based atmospheric spectra from the Total Carbon Column Observing Network (TCCON) and within the framework of the OCO-2 algorithm, using OCO-2 soundings covering a range of atmospheric and surface conditions. The updated absorption coefficients (ABSCO version 5.1) are found to offer improved fitting residuals and reduced biases in retrieved surface pressure relative to the previous version (ABSCO v5.0) used within B8 and B9 of the OCO-2 retrieval algorithm and have been adopted for the OCO B10 Level 2 algorithm

    Absorption Coefficient (ABSCO) Tables for the Orbiting Carbon Observatories: Version 5.1

    Get PDF
    The accuracy of atmospheric trace gas retrievals depends directly on the accuracy of the molecular absorption model used within the retrieval algorithm. For remote sensing of well-mixed gases, such as carbon dioxide (CO₂), where the atmospheric variability is small compared to the background, the quality of the molecular absorption model is key. Recent updates to oxygen (O₂) absorption coefficients (ABSCO) for the 0.76 μm A-band and the water vapor (H₂O) continuum model within the 1.6 μm and 2.06 μm CO₂ bands used within the Orbiting Carbon Observatory (OCO-2 and OCO-3) algorithm are described here. Updates in the O₂ A-band involve the inclusion of new laboratory measurements within multispectrum fits to improve relative consistency between O₂ line shapes and collision-induced absorption (CIA). The H₂O continuum model has been updated to MTCKD v3.2, which has benefited from information from a range of laboratory studies relative to the model utilized in the previous ABSCO version. Impacts of these spectroscopy updates have been evaluated against ground-based atmospheric spectra from the Total Carbon Column Observing Network (TCCON) and within the framework of the OCO-2 algorithm, using OCO-2 soundings covering a range of atmospheric and surface conditions. The updated absorption coefficients (ABSCO version 5.1) are found to offer improved fitting residuals and reduced biases in retrieved surface pressure relative to the previous version (ABSCO v5.0) used within B8 and B9 of the OCO-2 retrieval algorithm and have been adopted for the OCO B10 Level 2 algorithm

    Public health professionals' perceptions toward provision of health protection in England: a survey of expectations of Primary Care Trusts and Health Protection Units in the delivery of health protection

    Get PDF
    BACKGROUND: Effective health protection requires systematised responses with clear accountabilities. In England, Primary Care Trusts and the Health Protection Agency both have statutory responsibilities for health protection. A Memorandum of Understanding identifies responsibilities of both parties, but there is a potential lack of clarity about responsibility for specific health protection functions. We aimed to investigate professionals' perceptions of responsibility for different health protection functions, to inform future guidance for, and organisation of, health protection in England. METHODS: We sent a postal questionnaire to all health protection professionals in England from the following groups: (a) Directors of Public Health in Primary Care Trusts; (b) Directors of Health Protection Units within the Health Protection Agency; (c) Directors of Public Health in Strategic Health Authorities and; (d) Regional Directors of the Health Protection Agency RESULTS: The response rate exceeded 70%. Variations in perceptions of who should be, and who is, delivering health protection functions were observed within, and between, the professional groups (a)-(d). Concordance in views of which organisation should, and which does deliver was high (≥90%) for 6 of 18 health protection functions, but much lower (≤80%) for 6 other functions, including managing the implications of a case of meningitis out of hours, of landfill environmental contamination, vaccination in response to mumps outbreaks, nursing home infection control, monitoring sexually transmitted infections and immunisation training for primary care staff. The proportion of respondents reporting that they felt confident most or all of the time in the safe delivery of a health protection function was strongly correlated with the concordance (r = 0.65, P = 0.0038). CONCLUSION: Whilst we studied professionals' perceptions, rather than actual responses to incidents, our study suggests that there are important areas of health protection where consistent understanding of responsibility for delivery is lacking. There are opportunities to clarify the responsibility for health protection in England, perhaps learning from the approaches used for those health protection functions where we found consistent perceptions of accountability
    • …
    corecore