52 research outputs found

    Transaortic transcatheter aortic valve replacement with the Sapien™ valve and the first generations of Ascendra™

    Get PDF
    Traditionally, the transcatheter aortic valve replacement is performed through a transapical, a transfemoral or a trans-subclavian approach. Recently, the transaortic approach for transcatheter aortic valve replacement through the distal part of the ascending aorta was successfully implemented in order to avoid peripheral vascular access-related complications and apical life-threatening haemorrhage. The Sapien™ stent valve has great transaortic potential because it can be loaded ‘upside down' in different generations of delivery systems. However, because of their health regulatory systems and despite the launch, in 2012, of the latest generation of the Ascendra™ delivery system, the Ascendra+™, specifically designed for transapical and transaortic valve placements, several countries are still using the first generations of Ascendra™ (Ascendra™ 1 and 2). This device was specifically designed for transapical procedures, and retrograde stent-valve positioning through the stenotic aortic valve may be very challenging and risk the integrity of the aorta. We describe the manoeuvre required in order to pass the stenotic aortic valve safely in a retrograde direction using the Sapien™ stent valve and the first generations of Ascendra

    Imaging for trans-catheter pulmonary stent-valve implantation without angiography: role of intravascular ultrasound

    Get PDF
    Patients with stenosed biologic pulmonary conduits require redo cardiac surgery to prevent severe right ventricular dysfunction. Following the latest trends, the trans-catheter pulmonary stent-valve implantation represents a new fascinating alternative carrying a lower operative risk, compared with the standard open-heart re-intervention. Traditionally, the pulmonary stent valve is positioned off pump, under fluoroscopic control, and requires angiographies. However, alternative tools not requiring contrast injections for the intra-operative cardiac imaging have to be also considered strongly. The usefulness of intravascular ultrasound for the positioning of aortic endoprosthesis has already been proven in previous reports and, following the same principle, we have started to routinely implant balloon-expandable stent valves (Edwards Sapien™ THV) in stenosed pulmonary valve conduits using intravascular ultrasound for the stent-valve positioning without angiography. We describe the intra-operative intravascular imaging technique with technical detail

    Chimney grafts in renal arteries: a clinical model for coronary perfusion in future transcatheter aortic root repair techniques

    Full text link
    OBJECTIVES: Given the similarities between coronary ostia and renal arteries, chimney grafts (CG) for kidney perfusion during abdominal endovascular aneurysm repair (EVAR) can be considered for coronary perfusion in future transcatheter aortic root repair (TARR) techniques. We analysed the results of renal CG and compared anatomic and technical details with root and coronary anthropometric data. METHODS: Current status of kidney perfusion with CG was reviewed from literature. Anatomic details, technical data, CG performance and clinical outcome were collected and analysed. Anatomic details of aortic landing zone and renal arteries were compared with human anthropometric data of aortic root, ascending aorta and coronary ostia. RESULTS: Seventeen articles reported 430 patients (mean age:74.5 ± 2.9 years) treated with renal CG. Mean length and diameter of proximal landing zone were 2.0 ± 2.0 mm and 26.4 ± 4.3 mm, respectively (anthropometric correspondence: ascending aorta diameter of 29.3 mm). Aortic endograft mean diameter was 26.4 ± 7.3 mm with reported oversize of 19.5 ± 6.0%. In total, 590 renal arteries were treated (left:325; right:265; bilateral:139 cases). Mean left and right renal artery diameters were 5.7 ± 0.6 mm and 5.8 ± 0.7 mm, respectively (anthropometric correspondence: coronary ostia diameters of 4.8 mm (left) and 3.7 mm (right)) with reported CG oversize of 19.75 ± 6% (left) and 18.1 ± 5.1% (right). Mean follow-up time was 16.5 ± 8.5 months, CG occlusion rate was 3.2% and endoleak I or II was reported in 83 patients (19.3%), requiring 7 procedures. CONCLUSIONS: CG provides satisfactory results in patients with suitable renal artery diameter. Based on aortic root and coronary anthropometric data, CG can be considered in future TARR technologies for coronary perfusion but further tests for flow evaluations are mandatory

    Modified ‘dumbbell' technique: a simple and intuitive method to position balloon-expandable stent valves

    Get PDF
    Intraoperative cardiac imaging plays a key role during transcatheter aortic valve replacement. In recent years, new techniques and new tools for improved image quality and virtual navigation have been proposed, in order to simplify and standardize stent valve positioning and implantation. But routine performance of the new techniques may require major economic investments or specific knowledge and skills and, for this reason, they may not be accessible to the majority of cardiac centres involved in transcatheter valve replacement projects. Additionally, they still require injections of contrast medium to obtain computed images. Therefore, we have developed and describe here a very simple and intuitive method of positioning balloon-expandable stent valves, which represents the evolution of the ‘dumbbell' technique for echocardiography-guided transcatheter valve replacement without angiography. This method, based on the partial inflation of the balloon catheter during positioning, traps the crimped valve in the aortic valve orifice and, consequently, very near to the ideal landing zone. It does not require specific echocardiographic knowledge; it does not require angiographies that increase the risk of postoperative kidney failure in elderly patients, and it can be also performed in centres not equipped with a hybrid operating roo

    Incidence and risk factors for Contegra graft infection following right ventricular outflow tract reconstruction: long-term results

    Get PDF
    OBJECTIVES The aim of this study was to evaluate the risk factors associated with Contegra graft (Medtronic Minneapolis, MN, USA) infection after reconstruction of the right ventricular outflow tract. METHODS One hundred and six Contegra grafts were implanted between April 1999 and April 2010 for the Ross procedure (n = 46), isolated pulmonary valve replacement (n = 32), tetralogy of Fallot (n = 24), double-outlet right ventricle (n = 7), troncus arteriosus (n = 4), switch operation (n = 1) and redo of pulmonary valve replacement (n = 2). The median age of the patients was 13 years (range 0-54 years). A follow-up was completed in all cases with a median duration of 7.6 years (range 1.7-12.7 years). RESULTS There were 3 cases of in-hospital mortality. The survival rate during 7 years was 95.7%. Despite the lifelong endocarditis prophylaxis, Contegra graft infection was diagnosed in 12 (11.3%) patients at a median time of 4.4 years (ranging from 0.4 to 8.7 years). Univariate analysis of preoperative, perioperative and postoperative variables was performed and the following risk factors for time to infection were identified: female gender with a hazard ratio (HR) of 0.19 (P = 0.042), systemic-to-pulmonary shunt (HR 6.46, P < 0.01), hypothermia (HR 0.79, P = 0.014), postoperative renal insufficiency (HR 11.97, P = 0.015) and implantation of permanent pacemaker during hospitalization (HR 5.29, P = 0.075). In 2 cases, conservative therapy was successful and, in 10 patients, replacement of the infected valve was performed. The Contegra graft was replaced by a homograft in 2 cases and by a new Contegra graft in 8 cases. Cox's proportional hazard model indicated that time to graft infection was significantly associated with tetralogy of Fallot (HR 0.06, P = 0.01), systemic-to-pulmonary shunt (HR 64.71, P < 0.01) and hypothermia (HR 0.77, P < 0.01). CONCLUSION Contegra graft infection affected 11.3% of cases in our cohort, and thus may be considered as a frequent entity that can be predicted by both intraoperative and early postoperative factors. After the diagnosis of infection associated with the Contegra graft was confirmed, surgical treatment was the therapy of choic

    Geometric models of the aortic and pulmonary roots: suggestions for the Ross procedure

    Get PDF
    Objective: To discuss geometric factors, which may influence long-term results relating to homograft competence following the Ross procedure, we describe the 3D morphology of the pulmonary and aortic roots. Materials: Measurements were made on 25 human aortic and pulmonary roots. Inter-commissural distances and the heights of the sinuses were measured. For geometrical reconstruction the three commissures and their vertical projections at the root base were used as reference points. Results: In the pulmonary root, the three inter-commissural distances were of similar dimensions (17.9±1.6mm, 17.5±1.4mm and 18.6±1.5mm). In the aortic root, the right inter-commissural distance was greatest (18.8±1.9mm), followed by the non-coronary (17.4±2.0mm) and left coronary sinus commissures (15.2±1.9mm). The mean height of the left pulmonary sinus was greatest (20±1.7mm) followed by the anterior (17.5±1.4mm) and right pulmonary sinus (18±1.66mm). In the aortic root, the height of the right coronary sinus was the greatest (19.4±1.9mm) followed by the heights of the non-coronary (17.7±1.8mm) and left coronary sinus (17.4±1.4mm). Measured differences between parameters determine the tilt angle and direction of the root vector. The tilt angle in the pulmonary root averaged 16.26°, respectively; for the aortic roots, it was 5.47°. Conclusions: Herein we suggest that the left pulmonary sinus is best implanted in the position of the right coronary sinus, the anterior pulmonary in the position of the non-coronary sinus and the right pulmonary sinus in the position of the left coronary sinus. In this way, the direction of the pulmonary root vector will be parallel to that of the aortic root vecto
    corecore