41 research outputs found

    Direct patterning of organic conductors on knitted textiles for long-term electrocardiography.

    Get PDF
    Wearable sensors are receiving a great deal of attention as they offer the potential to become a key technological tool for healthcare. In order for this potential to come to fruition, new electroactive materials endowing high performance need to be integrated with textiles. Here we present a simple and reliable technique that allows the patterning of conducting polymers on textiles. Electrodes fabricated using this technique showed a low impedance contact with human skin, were able to record high quality electrocardiograms at rest, and determine heart rate even when the wearer was in motion. This work paves the way towards imperceptible electrophysiology sensors for human health monitoring

    High-performance transistors for bioelectronics through tuning of channel thickness.

    Get PDF
    UNLABELLED: Despite recent interest in organic electrochemical transistors (OECTs), sparked by their straightforward fabrication and high performance, the fundamental mechanism behind their operation remains largely unexplored. OECTs use an electrolyte in direct contact with a polymer channel as part of their device structure. Hence, they offer facile integration with biological milieux and are currently used as amplifying transducers for bioelectronics. Ion exchange between electrolyte and channel is believed to take place in OECTs, although the extent of this process and its impact on device characteristics are still unknown. We show that the uptake of ions from an electrolyte into a film of poly(3,4-ethylenedioxythiophene) doped with polystyrene sulfonate ( PEDOT: PSS) leads to a purely volumetric capacitance of 39 F/cm(3). This results in a dependence of the transconductance on channel thickness, a new degree of freedom that we exploit to demonstrate high-quality recordings of human brain rhythms. Our results bring to the forefront a transistor class in which performance can be tuned independently of device footprint and provide guidelines for the design of materials that will lead to state-of-the-art transistor performance

    Conducting Polymer Electrodes for Electroencephalography

    No full text
    Conducting polymer electrodes are developed on a flexible substrate for electroencephalography applications. These electrodes yield higher quality recordings than dry electrodes made from metal. Their performance is equivalent to commercial gel-assisted electrodes, paving the way for non-invasive, long-term monitoring of the human brain. © 2013 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim

    Organic electrochemical transistors for clinical applications

    No full text
    The ability of organic electrochemical transistors is explored to record human electrophysiological signals of clinical relevance. An organic electrochemical transistor (OECT) that shows a high (>1 mS) transconductance at zero applied gate voltage is used, necessitating only one power supply to bias the drain, while the gate circuit is driven by cutaneous electrical potentials. The OECT is successful in recording cardiac rhythm, eye movement, and brain activity of a human volunteer. These results pave the way for applications of OECTs as an amplifying transducer for human electrophysiology. It is shown that organic electrochemical transistors are able to record cardiac rhythm, eye movement, and brain activity in humans. These devices, therefore, show promise as amplifying transducers for the recoding of electrophysiological signals of clinical relevance

    Reverse Regulatory Pathway (H2S / PGE2 / MMP) in Human Aortic Aneurysm and Saphenous Vein Varicosity

    No full text
    Hydrogen sulfide (H2S) is a mediator with demonstrated protective effects for the cardiovascular system. On the other hand, prostaglandin (PG)E2 is involved in vascular wall remodeling by regulating matrix metalloproteinase (MMP) activities. We tested the hypothesis that endogenous H2S may modulate PGE2, MMP-1 activity and endogenous tissue inhibitors of MMPs (TIMP-1/-2). This regulatory pathway could be involved in thinning of abdominal aortic aneurysm (AAA) and thickening of saphenous vein (SV) varicosities. The expression of the enzyme responsible for H2S synthesis, cystathionine-γ-lyase (CSE) and its activity, were significantly higher in varicose vein as compared to SV. On the contrary, the endogenous H2S level and CSE expression were lower in AAA as compared to healthy aorta (HA). Endogenous H2S was responsible for inhibition of PGE2 synthesis mostly in varicose veins and HA. A similar effect was observed with exogenous H2S and consequently decreasing active MMP-1/TIMP ratios in SV and varicose veins. In contrast, in AAA, higher levels of PGE2 and active MMP-1/TIMP ratios were found versus HA. These findings suggest that differences in H2S content in AAA and varicose veins modulate endogenous PGE2 production and consequently the MMP/TIMP ratio. This mechanism may be crucial in vascular wall remodeling observed in different vascular pathologies (aneurysm, varicosities, atherosclerosis and pulmonary hypertension)
    corecore