137 research outputs found

    National fire regulations for the use of wood in buildings : worldwide review 2020

    No full text
    The possibilities for building in wood have gradually increased in recent decades mainly due to environmental benefits. But there are still restrictions in terms of fire regulations in many countries, especially for taller buildings. The situation has therefore been mapped in about 40 countries on four continents as an update to a survey in 2002. The main issues are how high buildings with load-bearing wooden frames may be built and how much visible wood may be used both inside and outside on facades. The restrictions apply primarily to prescriptive fire design according to simplified design with detailed rules, which are mainly used for residential buildings and offices. For more complicated constructions e.g. public buildings, shopping centers, arenas and assembly halls, performance based design can be used by fire safety engineering design using, e.g. methods for evacuation and smoke filling, which increases the possibilities of using wood in buildings. The possibilities to use wood in buildings increase if sprinklers are installed, which is highlighted. Major differences between countries have been identified, both in terms of the number of storeys permitted in wood structures, and of the amounts of visible wood surfaces in interior and exterior applications. Several countries have no specific regulations, or do not limit the number of storeys in wooden buildings. The conclusion is that the differences are still large and that many countries have not yet started to use larger wood constructions despite supplies of forest resources, but harmonizing activities on performance based principles are ongoing worldwide

    Results of Scandinavian tests and research on reaction to fire. Paper presented at the Eurowood Oxford Fire Conference, July 1993

    No full text
    Brandens tidiga skede är avgörande för personsäkerheten vid utrymning av ett rum, en lägenhet eller en byggnad. Kunskapen har länge varit bristfällig inom området. Därför har det varit angeläget att ta fram ny kunskap och att utveckla experimentella och teoretiska metoder som förbättrar möjligheterna att förutsäga det tidiga brandförloppet och bedöma risker i olika brandmiljöer. Sverige och Norden i övrigt bedriver internationellt uppmärksammad forskning inom området. De omfattande projekten "Brandrisker i det tidiga brandförloppet" och "Eurefic" har lett till standardiserade provningsmetoder och ytterligare standardiseringar diskuteras. New techniques based on oxygen consumption as the cone calorimerer and the room fire test have been studied and utilized. Different models which predict the full-scale behaviour from small-scale data have been developed. These models clearly show that the new technique is superior to the present national standards and thus supplies new possibilities

    Publikationer Trä och brandsäkerhet 1973-2022

    No full text

    Fire resistance of timber structures - National guidelines in European and some other countries 2002

    No full text
    Brandmotstånd hos träkonstruktioner efterfrågas alltmer, särskilt för större och högre hus, som nu får byggas med trästomme i större utsträckning till följd av att mer funktionsbaserade byggregler införs i allt fler länder.Tillgängliga data över brandmotstånd hos träkonstruktioner (väggar och bjälklag) har därför sammanställts och baseras på befintlig dokumentation i fjorton europeiska och fyra utomeuropeiska länder (Australien, Kanada, Nya Zeeland och USA). Både lätta sammansatta och massiva träkonstruktioner för bärande och/eller avskiljande väggar och för bjälklag ingår i översikten

    Ignitability in the cone calorimeter and the ISO ignitability test

    No full text
    Det finns flera standardiserade sätt att mäta antändligheten hos byggnadsmaterial. Här har data för samma byggnadsmaterial jämförts för de 2 vanligaste metoderna, konkalorimetern och ISOs antändlighetstest, den senare svensk standard. Analysen visar att ungefär samma värden erhålls för tid till antändning med de 2 metoderna. Konkalorimetern är att föredra som småskalig brandprovningsmetod även för bestämning av tid till antändning eftersom den också mäter flera andra parametrar samtidigt. Den bör således kunna ersätta ISOs antändlighetstest. Rapport på engelska med utförlig svensk sammanfattning
    • …
    corecore