Microwave Dielectric Heating of Drops in Microfluidic Devices
We present a technique to locally and rapidly heat water drops in
microfluidic devices with microwave dielectric heating. Water absorbs microwave
power more efficiently than polymers, glass, and oils due to its permanent
molecular dipole moment that has a large dielectric loss at GHz frequencies.
The relevant heat capacity of the system is a single thermally isolated
picoliter drop of water and this enables very fast thermal cycling. We
demonstrate microwave dielectric heating in a microfluidic device that
integrates a flow-focusing drop maker, drop splitters, and metal electrodes to
locally deliver microwave power from an inexpensive, commercially available 3.0
GHz source and amplifier. The temperature of the drops is measured by observing
the temperature dependent fluorescence intensity of cadmium selenide
nanocrystals suspended in the water drops. We demonstrate characteristic
heating times as short as 15 ms to steady-state temperatures as large as 30
degrees C above the base temperature of the microfluidic device. Many common
biological and chemical applications require rapid and local control of
temperature, such as PCR amplification of DNA, and can benefit from this new
technique.Comment: 6 pages, 4 figure
Scaling of transverse nuclear magnetic relaxation due to magnetic nanoparticle aggregation
The aggregation of superparamagnetic iron oxide (SPIO) nanoparticles
decreases the transverse nuclear magnetic resonance (NMR) relaxation time T2 of
adjacent water molecules measured by a Carr-Purcell-Meiboom-Gill (CPMG)
pulse-echo sequence. This effect is commonly used to measure the concentrations
of a variety of small molecules. We perform extensive Monte Carlo simulations
of water diffusing around SPIO nanoparticle aggregates to determine the
relationship between T2 and details of the aggregate. We find that in the
motional averaging regime T2 scales as a power law with the number N of
nanoparticles in an aggregate. The specific scaling is dependent on the fractal
dimension d of the aggregates. We find T2 N^{-0.44} for aggregates with d=2.2,
a value typical of diffusion limited aggregation. We also find that in
two-nanoparticle systems, T2 is strongly dependent on the orientation of the
two nanoparticles relative to the external magnetic field, which implies that
it may be possible to sense the orientation of a two-nanoparticle aggregate. To
optimize the sensitivity of SPIO nanoparticle sensors, we propose that it is
best to have aggregates with few nanoparticles, close together, measured with
long pulse-echo times.Comment: 20 pages, 3 figures, submitted to Journal of Magnetism and Magnetic
Material
Recommended from our members
High Voltage Dielectrophoretic and Magnetophoretic Hybrid Integrated Circuit / Microfluidic Chip
A hybrid integrated circuit (IC)/microfluidic chip is presented that independently and simultaneously traps and moves microscopic objects suspended in fluid using both electric and magnetic fields. This hybrid chip controls the location of dielectric objects, such as living cells and drops of fluid, on a 60 times 61 array of pixels that are 30 times 38 mum2 in size, each of which can be individually addressed with a 50-V peak-to-peak dc-to-10-MHz radio-frequency voltage. These high-voltage pixels produce electric fields above the chip's surface with a magnitude |oarrE| ap 1 V/ mum, resulting in strong dielectrophoresis (DEP) forces |oarrFDEP| ap 1 nN. Underneath the array of DEP pixels, there is a magnetic matrix that consists of two perpendicular sets of 60 metal wires running across the chip. Each wire can be sourced with 120 mA to trap and move magnetically susceptible objects using magnetophoresis. The DEP pixel array and magnetic matrix can be used simultaneously to apply forces to microscopic objects, such as living cells or lipid vesicles, that are tagged with magnetic nanoparticles. The capabilities of the hybrid IC/microfluidic chip demonstrated in this paper provide important building blocks for a platform for biological and chemical applications.Engineering and Applied Science
Recommended from our members
Integrated Circuit / Microfluidic Chips for Dielectric Manipulation
Engineering and Applied Science
Magnetic Nanoparticles and microNMR for Diagnostic Applications
Sensitive and quantitative measurements of clinically relevant protein biomarkers, pathogens and cells in biological samples would be invaluable for disease diagnosis, monitoring of malignancy, and for evaluating therapy efficacy. Biosensing strategies using magnetic nanoparticles (MNPs) have recently received considerable attention, since they offer unique advantages over traditional detection methods. Specifically, because biological samples have negligible magnetic background, MNPs can be used to obtain highly sensitive measurements in minimally processed samples. This review focuses on the use of MNPs for in vitro detection of cellular biomarkers based on nuclear magnetic resonance (NMR) effects. This detection platform, termed diagnostic magnetic resonance (DMR), exploits MNPs as proximity sensors to modulate the spin-spin relaxation time of water molecules surrounding the molecularly-targeted nanoparticles. With new developments such as more effective MNP biosensors, advanced conjugational strategies, and highly sensitive miniaturized NMR systems, the DMR detection capabilities have been considerably improved. These developments have also enabled parallel and rapid measurements from small sample volumes and on a wide range of targets, including whole cells, proteins, DNA/mRNA, metabolites, drugs, viruses and bacteria. The DMR platform thus makes a robust and easy-to-use sensor system with broad applications in biomedicine, as well as clinical utility in point-of-care settings
Fabrication and Characterization of Modulation-Doped ZnSe/(Zn,Cd)Se (110) Quantum Wells: A New System for Spin Coherence Studies
We describe the growth of modulation-doped ZnSe/(Zn,Cd)Se quantum wells on
(110) GaAs substrates. Unlike the well-known protocol for the epitaxy of
ZnSe-based quantum structures on (001) GaAs, we find that the fabrication of
quantum well structures on (110) GaAs requires significantly different growth
conditions and sample architecture. We use magnetotransport measurements to
confirm the formation of a two-dimensional electron gas in these samples, and
then measure transverse electron spin relaxation times using time-resolved
Faraday rotation. In contrast to expectations based upon known spin relaxation
mechanisms, we find surprisingly little difference between the spin lifetimes
in these (110)-oriented samples in comparison with (100)-oriented control
samples.Comment: To appear in Journal of Superconductivity (Proceedings of 3rd
Conference on Physics and Applications of Spin-dependent Phenomena in
Semiconductors
Toolbox for Exploring Modular Gene Regulation in Synthetic Biology Training
We report a toolbox for exploring the modular tuning of genetic circuits, which has been specifically optimized for widespread deployment in STEM environments through a combination of bacterial strain engineering and distributable hardware development. The transfer functions of 16 genetic switches, programmed to express a GFP reporter under the regulation of the (acyl-homoserine lactone) AHL-sensitive luxR transcriptional activator, can be parametrically tuned by adjusting high/low degrees of transcriptional, translational, and post-translational processing. Strains were optimized to facilitate daily large-scale preparation and reliable performance at room temperature in order to eliminate the need for temperature controlled apparatuses, which are both cost-limiting and space-constraining. The custom-designed, automated, and web-enabled fluorescence documentation system allows time-lapse imaging of AHL-induced GFP expression on bacterial plates with real-time remote data access, thereby requiring trainees to only be present for experimental setup. When coupled with mathematical models in agreement with empirical data, this toolbox expands the scalability and scope of reliable synthetic biology experiments for STEM training
Recommended from our members
Microwave dielectric heating of non-aqueous droplets in a microfluidic device for nanoparticle synthesis
We describe a microfluidic device with an integrated microwave heater specifically designed to dielectrically heat non-aqueous droplets using time-varying electrical fields with the frequency range between 700 and 900 MHz. The precise control of frequency, power, temperature and duration of the applied field opens up new vistas for experiments not attainable by conventional microwave heating. We use a non-contact temperature measurement system based on fluorescence to directly determine the temperature inside a single droplet. The maximum temperature achieved of the droplets is 50 °C in 15 ms which represents an increase of about 25 °C above the base temperature of the continuous phase. In addition we use an infrared camera to monitor the thermal characteristics of the device allowing us to ensure that heating is exclusively due to the dielectric heating and not due to other effects like non-dielectric losses due to electrode or contact imperfection. This is crucial for illustrating the potential of dielectric heating of benzyl alcohol droplets for the synthesis of metal oxides. We demonstrate the utility of this technology for metal oxide nanoparticle synthesis, achieving crystallization of tungsten oxide nanoparticles and remarkable microstructure, with a reaction time of 64 ms, a substantial improvement over conventional heating methods.Engineering and Applied SciencesPhysic
- …