6 research outputs found

    Calibration and discriminatory accuracy of prognosis calculation for breast cancer with the online Adjuvant! program: A hospital-based retrospective cohort study

    No full text
    Background Adjuvant! is a web-based program that calculates individualised 10-year survival probabilities and predicted benefit of adjuvant systemic therapy. The Adjuvant! model has not been validated in any large European series. The aim of our study was to validate Adjuvant! in Dutch patients, investigating both its calibration and discriminatory accuracy. Methods Patients who were at least partly treated at the Netherlands Cancer Institute for breast cancer between 1987 and 1998 were included if they met the following criteria: tumour size T1 (≀2 cm), T2 (2–5 cm), or T3 (>5 cm), invasive breast carcinoma, with information about involvement of axillary lymph nodes available, no distant metastases, primary surgery, axillary staging, and radiotherapy according to national guidelines. Clinicopathological characteristics and adjuvant treatment data were retrieved from hospital records and medical registries and were entered into the Adjuvant! (version 8.0) batch processor with blinding to outcome. Endpoints were overall survival and the proportion of patients that did not die from breast cancer (breast-cancer-specific survival [BCSS]). Findings 5380 patients were included with median follow-up of 11‱7 years (range 0‱03–21‱8). The 10-year observed overall survival (69‱0%) and BCSS (78‱6%) and Adjuvant! predicted overall survival (69‱1%) and BCSS (77‱8%) were not statistically different (p=0‱87 and p=0‱18, respectively). Moreover, differences between predicted and observed outcomes were within 2% for most relevant clinicopathological subgroups. In patients younger than 40 years, Adjuvant! overestimated overall survival by 4‱2% (p=0‱04) and BCSS by 4‱7% (p=0‱01). The concordance index, which indicates discriminatory accuracy at the individual level, was 0‱71 for BCSS in the entire cohort. Interpretation Adjuvant! accurately predicted 10-year outcomes in this large-scale Dutch validation study and is of use for adjuvant treatment decision making, although the results may be less reliable in some subgroups. Funding Dutch National Genomics Initiative-Cancer Genomics Center, Dutch Cancer Society-KWF

    Extracorporeal Membrane Oxygenation in Patients With COVID-19: An International Multicenter Cohort Study

    No full text
    Background:To report and compare the characteristics and outcomes of COVID-19 patients on extracorporeal membrane oxygenation (ECMO) to non-COVID-19 acute respiratory distress syndrome (ARDS) patients on ECMO.Methods:We performed an international retrospective study of COVID-19 patients on ECMO from 13 intensive care units from March 1 to April 30, 2020. Demographic data, ECMO characteristics and clinical outcomes were collected. The primary outcome was to assess the complication rate and 28-day mortality; the secondary outcome was to compare patient and ECMO characteristics between COVID-19 patients on ECMO and non-COVID-19 related ARDS patients on ECMO (non-COVID-19; January 1, 2018 until July 31, 2019).Results:During the study period 71 COVID-19 patients received ECMO, mostly veno-venous, for a median duration of 13 days (IQR 7-20). ECMO was initiated at 5 days (IQR 3-10) following invasive mechanical ventilation. Median PaO2/FiO(2) ratio prior to initiation of ECMO was similar in COVID-19 patients (58 mmHg [IQR 46-76]) and non-COVID-19 patients (53 mmHg [IQR 44-66]), the latter consisting of 48 patients. 28-day mortality was 37% in COVID-19 patients and 27% in non-COVID-19 patients. However, Kaplan-Meier curves showed that after a 100-day follow-up this non-significant difference resolves. Non-surviving COVID-19 patients were more acidotic prior to initiation ECMO, had a shorter ECMO run and fewer received muscle paralysis compared to survivors.Conclusions:No significant differences in outcomes were found between COVID-19 patients on ECMO and non-COVID-19 ARDS patients on ECMO. This suggests that ECMO could be considered as a supportive therapy in case of refractory respiratory failure in COVID-19

    Extracorporeal Membrane Oxygenation in Patients With COVID-19: An International Multicenter Cohort Study

    No full text
    Background:To report and compare the characteristics and outcomes of COVID-19 patients on extracorporeal membrane oxygenation (ECMO) to non-COVID-19 acute respiratory distress syndrome (ARDS) patients on ECMO.Methods:We performed an international retrospective study of COVID-19 patients on ECMO from 13 intensive care units from March 1 to April 30, 2020. Demographic data, ECMO characteristics and clinical outcomes were collected. The primary outcome was to assess the complication rate and 28-day mortality; the secondary outcome was to compare patient and ECMO characteristics between COVID-19 patients on ECMO and non-COVID-19 related ARDS patients on ECMO (non-COVID-19; January 1, 2018 until July 31, 2019).Results:During the study period 71 COVID-19 patients received ECMO, mostly veno-venous, for a median duration of 13 days (IQR 7-20). ECMO was initiated at 5 days (IQR 3-10) following invasive mechanical ventilation. Median PaO2/FiO(2) ratio prior to initiation of ECMO was similar in COVID-19 patients (58 mmHg [IQR 46-76]) and non-COVID-19 patients (53 mmHg [IQR 44-66]), the latter consisting of 48 patients. 28-day mortality was 37% in COVID-19 patients and 27% in non-COVID-19 patients. However, Kaplan-Meier curves showed that after a 100-day follow-up this non-significant difference resolves. Non-surviving COVID-19 patients were more acidotic prior to initiation ECMO, had a shorter ECMO run and fewer received muscle paralysis compared to survivors.Conclusions:No significant differences in outcomes were found between COVID-19 patients on ECMO and non-COVID-19 ARDS patients on ECMO. This suggests that ECMO could be considered as a supportive therapy in case of refractory respiratory failure in COVID-19

    RBC Transfusion in Venovenous Extracorporeal Membrane Oxygenation: A Multicenter Cohort Study

    No full text
    OBJECTIVES: In the general critical care patient population, restrictive transfusion regimen of RBCs has been shown to be safe and is yet implemented worldwide. However, in patients on venovenous extracorporeal membrane oxygenation, guidelines suggest liberal thresholds, and a clear overview of RBC transfusion practice is lacking. This study aims to create an overview of RBC transfusion in venovenous extracorporeal membrane oxygenation. DESIGN: Mixed method approach combining multicenter retrospective study and survey. SETTING: Sixteen ICUs worldwide. PATIENTS: Patients receiving venovenous extracorporeal membrane oxygenation between January 2018 and July 2019. INTERVENTIONS: None. MEASUREMENTS AND MAIN RESULTS: The primary outcome was the proportion receiving RBC, the amount of RBC units given daily and in total. Furthermore, the course of hemoglobin over time during extracorporeal membrane oxygenation was assessed. Demographics, extracorporeal membrane oxygenation characteristics, and patient outcome were collected. Two-hundred eight patients received venovenous extracorporeal membrane oxygenation, 63% male, with an age of 55 years (45-62 yr), mainly for acute respiratory distress syndrome. Extracorporeal membrane oxygenation duration was 9 days (5-14 d). Prior to extracorporeal membrane oxygenation, hemoglobin was 10.8 g/dL (8.9-13.0 g/dL), decreasing to 8.7 g/dL (7.7-9.8 g/dL) during extracorporeal membrane oxygenation. Nadir hemoglobin was lower on days when a transfusion was administered (8.1 g/dL [7.4-9.3 g/dL]). A vast majority of 88% patients received greater than or equal to 1 RBC transfusion, consisting of 1.6 U (1.3-2.3 U) on transfusion days. This high transfusion occurrence rate was also found in nonbleeding patients (81%). Patients with a liberal transfusion threshold (hemoglobin > 9 g/dL) received more RBC in total per transfusion day and extracorporeal membrane oxygenation day. No differences in survival, hemorrhagic and thrombotic complication rates were found between different transfusion thresholds. Also, 28-day mortality was equal in transfused and nontransfused patients. CONCLUSIONS: Transfusion of RBC has a high occurrence rate in patients on venovenous extracorporeal membrane oxygenation, even in nonbleeding patients. There is a need for future studies to find optimal transfusion thresholds and triggers in patients on extracorporeal membrane oxygenation

    Alignment of the CMS tracker with LHC and cosmic ray data

    No full text
    The central component of the CMS detector is the largest silicon tracker ever built. The precise alignment of this complex device is a formidable challenge, and only achievable with a significant extension of the technologies routinely used for tracking detectors in the past. This article describes the full-scale alignment procedure as it is used during LHC operations. Among the specific features of the method are the simultaneous determination of up to 200 000 alignment parameters with tracks, the measurement of individual sensor curvature parameters, the control of systematic misalignment effects, and the implementation of the whole procedure in a multi-processor environment for high execution speed. Overall, the achieved statistical accuracy on the module alignment is found to be significantly better than 10Όm.© CERN 2014 for the benefit of the CMS collaboration.
    corecore