475 research outputs found

    Evaluation of Methods for Sampling the Malaria Vector Anopheles darlingi (Diptera, Culicidae) in Suriname and the Relation With Its Biting Behavior

    Get PDF
    The effectiveness of CO2-baited and human-baited mosquito traps for the sampling of Anopheles darlingi Root was evaluated and compared with human landing collections in Suriname. Biting preferences of this mosquito on a human host were studied and related to trapping data. Traps used were the Centers for Disease Control and Prevention Miniature Light trap, the BG Sentinel mosquito trap, the Mosquito Magnet Liberty Plus mosquito trap (MM-Plus), and a custom-designed trap. Carbon dioxide and humans protected by a bed net were used as bait in the studies. The number of An. darlingi collected was greater with human landing collections than with all other collection methods. An. darlingi did not show a preference for protected humans over CO2 bait. The BG Sentinel mosquito trap with CO2 or human odor as bait and the MM-Plus proved the best alternative sampling tools for An. darlingi. The BG Sentinel mosquito trap with CO2 or human odor as bait was also very efficient at collecting Culex spp. In a field study on biting preferences of wild An. darlingi, the females showed directional biting behavior (P <0.001), with a majority of females (93.3%) biting the lower legs and feet when approaching a seated human host. Higher efficiency of the closer-to-the-ground collecting MM-Plus and BG Sentinel mosquito trap when compared with the other trapping methods may be a result of a possible preference of this mosquito species for low-level biting. It is concluded that odor-baited sampling systems can reliably collect An. darlingi, but the odor bait needs to be improved, for instance, by including host-specific volatiles, to match live human baits

    Carbon dioxide baited trap catches do not correlate with human landing collections of Anopheles aquasalis in Suriname

    Get PDF
    Three types of carbon dioxide-baited traps, i.e., the Centers for Disease Control Miniature Light Trap without light, the BioGents (BG) Sentinel Mosquito Trap (BG-Sentinel) and the Mosquito Magnet® Liberty Plus were compared with human landing collections in their efficiency in collecting Anopheles (Nyssorhynchus) aquasalis mosquitoes. Of 13,549 total mosquitoes collected, 1,019 (7.52%) were An. aquasalis. Large numbers of Culex spp were also collected, in particular with the (BG-Sentinel). The majority of An. aquasalis (83.8%) were collected by the human landing collection (HLC). None of the trap catches correlated with HLC in the number of An. aquasalis captured over time. The high efficiency of the HLC method indicates that this malaria vector was anthropophilic at this site, especially as carbon dioxide was insufficiently attractive as stand-alone bait. Traps using carbon dioxide in combination with human odorants may provide better results

    Performance of the Eversense versus the Free Style Libre Flash glucose monitor during exercise and normal daily activities in subjects with type 1 diabetes mellitus

    Get PDF
    Introduction Accurate blood glucose measurements are important in persons with diabetes during normal daily activities (NDA), even more so during exercise. We aimed to investigate the performance of fluorescence sensor-based and glucose oxidase-based interstitial glucose measurement during (intensive) exercise and NDA. Research design and methods Prospective, observational study in 23 persons with type 1 diabetes when mountain biking for 6 days, followed by 6 days of NDA. Readings of the Eversense (fluorescence-based continuous glucose monitoring (CGM); subcutaneously implanted) and of the Free Style Libre (FSL; glucose oxidase-based flash glucose monitoring (FGM); transcutaneously placed) were compared with capillary glucose levels (Free Style Libre Precision NeoPro strip (FSLCstrip)). Results Mean average differences (MAD) and mean average relative differences (MARD) were significantly different when comparing exercise with NDA (reference FSLCstrip); Eversense MAD 25±19 vs 17±6 mg/dL (p<0.001); MARD 17±6 vs 13%±6% (p<0.01) and FSL MAD 32±17 vs 18±8 mg/dL (p<0.01); MARD 20±7 vs 12%±5% (p<0.001). When analyzing the data according to the Integrated Continuous Glucose Monitoring Approvals (class II-510(K) guidelines), the overall performance of interstitial glucose readings within 20% of the FSLCstrip during exercise compared with NDA was 69% vs 81% for the Eversense and 59% vs 83% for the FSL, respectively. Within 15% of the FSLCstrip was 59% vs 70% for the Eversense and 46% vs 71% for the FSL. Conclusions During exercise, both fluorescence and glucose oxidase-based interstitial glucose measurements (using Eversense and FSL sensors) were less accurate compared with measurements during NDA. Even when acknowledging the beneficial effects of CGM or FGM, users should be aware of the risk of diminished accuracy of interstitial glucose readings during (intensive) exercise

    Lower Extremity Amputation Rates in People With Diabetes Mellitus:A Retrospective Population Based Cohort Study in Zwolle Region, The Netherlands

    Get PDF
    OBJECTIVE: Lower extremity amputations are a major complication of diabetes mellitus (DM). In a previous Dutch study, the incident rate of major amputations was 89.2 per 100 000 person years. The primary aim of this study was to describe the lower extremity amputation rates in people with DM in the Zwolle region, where preventive and curative footcare is organised according to the guidelines of the International Working Group of the Diabetic Foot (IWGDF). The secondary aim was to evaluate outcomes and underlying characteristics of these people.METHODS: This was a retrospective regional population based cohort study. Data from all people with DM treated in primary and secondary care, living in the region Zwolle were collected. All amputations in the period 2017 to 2019 were analysed. Comparisons were made between those with and without an amputation.RESULTS: In the analysis 5 915 people with DM were included, with a mean age of 67.8 (IQR 57.9, 75.9) years. Of those people, 47% were women and the median HbA1c was 53 (IQR 47, 62) mmol/mol. Over the three year study period, a total of 68 amputations were performed in 59 people: 46 minor, 22 major. This translated into an average annual crude amputation incidence rate of non-traumatic major and minor amputations of 41.5 and 86.9 per 100 000 person years among people with diabetes. Compared with those not undergoing amputations, those who underwent an amputation were more often men, older, mainly had T2DM, were treated in secondary care, had higher diastolic blood pressure, worse diabetic footcare profile, longer DM duration and higher HbA1c. At the end of the follow up, 111 people died: 96 (1.6%) without and 15 (25.4%) with amputations (p &lt; .001).CONCLUSIONS: This retrospective study provides detailed insight into the rate of amputations in Dutch people with diabetes in the region Zwolle. Compared with previous Dutch estimates, these data suggest a considerable decrease in major amputation incidence rate.</p

    Recovery Courses of Patients Who Return to Work by 3, 6 or 12 Months After Total Knee Arthroplasty

    Get PDF
    Purpose This study compared the preoperative levels and postoperative recovery courses of physical and mental impairments, activity limitations and participation restrictions of working-age patients who return to work (RTW) by 3, 6 or 12 months after total knee arthroplasty (TKA). Methods A prospective survey study including TKA patients (aged < 65) (n = 146) who returned to work (RdTW) in the first postoperative year. Three groups were compared: those who returned by 3 (n = 35), 6 (n = 40) or 12 (n = 29) months. Surveys were completed preoperatively and at 6 weeks and 3, 6 and 12 months postoperatively. Outcomes represented domains of the International Classification of Functioning, i.e. physical impairments (pain, stiffness, vitality), mental impairments (mental health and depressive symptoms), activity limitations (physical functioning) and participation restrictions (social and work functioning). Results Preoperative knee-specific pain and physical functioning levels were better among patients who RdTW by 3 months, compared to those who returned by 12 months. Patients who RdTW by 3 months experienced significantly better recovery from physical impairments than those who returned by 6 months (on general pain) or 12 months (on general and knee-specific pain and on stiffness). Patients returning by 3 months experienced significantly better recovery from activity limitations (on knee-specific physical functioning). Conclusions To optimize return to work outcome after TKA surgery, the focus should lie on physical impairments (general and knee-specific pain, stiffness) and activity limitations (knee-specific physical functioning) during recovery

    Real-life 24-week changes in glycemic parameters among European users of flash glucose monitoring with type 1 and 2 diabetes and different levels of glycemic control

    Get PDF
    AIM: To evaluate real-life changes of glycemic parameters among flash glucose monitoring (FLASH) users who do not meet glycemic targets.METHODS: De-identified data were obtained between 2014 and 2021 from patients using FLASH uninterrupted for a 24-week period. Glycemic parameters during first and last sensor use were examined in four identifiable groups: type 1 diabetes mellitus (T1DM), type 2 diabetes mellitus (T2DM) on basal-bolus insulin, T2DM on basal insulin, and T2DM without insulin treatment. Within each group, subgroup analyses were performed in persons with initial suboptimal glycemic regulation (time in range (TIR; 3.9-10 mmol/L) &lt; 70%, time above range (TAR; &gt;10 mmol/L) &gt; 25%, or time below range (TBR; &lt;3.9 mmol/L) &gt; 4%).RESULTS: Data were obtained from 1,909 persons with T1DM and 1,813 persons with T2DM (1,499 basal-bolus insulin, 189 basal insulin, and 125 non-insulin users). In most of the performed analyses, both overall and in the various subgroups, significant improvements were observed in virtually all predefined primary (TIR) and secondary endpoints (eHbA1c, TAR, TBR and glucose variability).CONCLUSIONS: 24-weeks FLASH use in real life by persons with T1DM and T2DM with suboptimal glycemic regulation is associated with improvement of glycemic parameters, irrespective of pre-use regulation or treatment modality.</p

    Analysis of variance for testing method of cement in determination of strength

    Get PDF
    AbstractThe statistical tools such as descriptive statistics, full factorial design and analysis of source of variation were used to identify the potential factors that impact the validity of testing method for determining the strength of cement. The results showed that personal error impacted both accuracy and precision of test greatly. Experimental time associated with temperature fluctuation resulted in strength variation but did not impact the precision of test in all curing ages. Different compactions did not impact the precision of test but resulted in the strength variation on 3 d and 28 d significantly. Different methods for the initial moist air curing significantly impacted the precision of testing method and resulted in the strength variation of cement on 1 d

    Favourable serum calcification propensity with intraperitoneal as compared with subcutaneous insulin administration in type 1 diabetes

    Get PDF
    Background: Serum calcification propensity can be monitored using the maturation time of calciprotein particles in serum (T-50 test). A shorter T-50 indicates greater propensity to calcify; this is an independent determinant of cardiovascular disease. As the intraperitoneal (IP) route of insulin administration mimics the physiology more than the subcutaneous (SC) route in persons with type 1 diabetes (T1DM), we hypothesized that IP insulin influences determinants of calcium propensity and therefore result in a longer T-50 than SC insulin administration. Methods: Prospective, observational case-control study. Measurements were performed at baseline and at 26 weeks in age and gender matched persons with T1DM. Results: A total of 181 persons, 39 (21.5%) of which used IP and 142 (78.5%) SC insulin were analysed. Baseline T-50 was 356 (45) minutes. The geometric mean T-50 significantly differed between both treatment groups: 367 [95% confidence interval (CI) 357, 376] for the IP group and 352 (95% CI 347, 357) for the SC group with a difference of -15 (95% CI -25, -4) minutes, in favour of IP treatment. In multivariable analyses, the IP route of insulin administration had a positive relation on T-50 concentrations while higher age, triglycerides and phosphate concentrations had an inverse relation. Conclusion: Among persons with T1DM, IP insulin administration results in a more favourable calcification propensity time then SC insulin. It has yet to be shown if this observation translates into improved cardiovascular outcomes
    corecore