9 research outputs found

    Flushing of an intravenous catheter: a cause for unreliable laboratory results

    Get PDF
    Introduction: Phlebotomy is an error-prone process in which mistakes are difficult to reveal. This case report describes the effect on laboratory results originating from a blood sample collected in close proximity to an intravenous catheter. Materials and methods: A 69-year-old male patient was referred to the Emergency department where pneumonia was suspected. Phlebotomy was performed to collect blood samples to assess electrolytes, renal function, liver function, infection and haematological parameters. Results: The laboratory analysis showed reduced potassium and calcium concentrations. To prevent life-threatening cardiac failure the clinician decided to correct those electrolytes. Remarkably, the electrocardiogram showed no abnormalities corresponding to hypokalaemia and hypocalcaemia. This observation, in combination with an overall increase in laboratory parameters with the exception of sodium and chloride, led to the suspicion of a preanalytical error. Retrospectively, an intravenous catheter was inserted in close proximity of the puncture place but no continuous infusion was started prior to phlebotomy. However, the intravenous catheter was flushed with sodium chloride. Since potential other causes were excluded, the flushing of the intravenous catheter with sodium chloride prior to phlebotomy was the most probable cause for the deviating laboratory results and subsequently for the unnecessary potassium and calcium suppletion. Conclusion: This case underlines the importance of caution in the interpretation of laboratory results obtained from specimens that are collected in the proximity of an intravenous catheter, even in the absence of continuous infusion

    Patient identification and tube labelling:a call for harmonisation

    Get PDF
    Venous blood sampling (phlebotomy) is the most common invasive procedure performed in patient care. Guidelines on the correct practice of phlebotomy are available, including the H3-A6 guideline issued by the Clinical Laboratory Standards Institute (CLSI). As the quality of practices and procedures related to venous blood sample collection in European countries was unknown, the European Federation of Clinical Chemistry and Laboratory Medicine (EFLM) Working Group for the Preanalytical Phase conducted an observational study in 12 European countries. The study demonstrated that the level of compliance of phlebotomy procedures with the CLSI H3-A6 guideline was unacceptably low, and that patient identification and tube labelling are amongst the most critical steps in need of immediate attention and improvement. The process of patient identification and tube labelling is an essential safety barrier to prevent patient identity mix-up. Therefore, the EFLM Working Group aims to encourage and support worldwide harmonisation of patient identification and tube labelling procedures in order to reduce the risk of preanalytical errors and improve patient safety. With this Position paper we wish to raise awareness and provide recommendations for proper patient and sample identification procedure

    Flushing of an intravenous catheter: a cause for unreliable laboratory results

    No full text
    Introduction: Phlebotomy is an error-prone process in which mistakes are difficult to reveal. This case report describes the effect on laboratory results originating from a blood sample collected in close proximity to an intravenous catheter. Materials and methods: A 69-year-old male patient was referred to the Emergency department where pneumonia was suspected. Phlebotomy was performed to collect blood samples to assess electrolytes, renal function, liver function, infection and haematological parameters. Results: The laboratory analysis showed reduced potassium and calcium concentrations. To prevent life-threatening cardiac failure the clinician decided to correct those electrolytes. Remarkably, the electrocardiogram showed no abnormalities corresponding to hypokalaemia and hypocalcaemia. This observation, in combination with an overall increase in laboratory parameters with the exception of sodium and chloride, led to the suspicion of a preanalytical error. Retrospectively, an intravenous catheter was inserted in close proximity of the puncture place but no continuous infusion was started prior to phlebotomy. However, the intravenous catheter was flushed with sodium chloride. Since potential other causes were excluded, the flushing of the intravenous catheter with sodium chloride prior to phlebotomy was the most probable cause for the deviating laboratory results and subsequently for the unnecessary potassium and calcium suppletion. Conclusion: This case underlines the importance of caution in the interpretation of laboratory results obtained from specimens that are collected in the proximity of an intravenous catheter, even in the absence of continuous infusion

    Point accuracy and reliability of an interstitial continuous glucose-monitoring device in critically ill patients: a prospective study

    No full text
    There is a need for continuous glucose monitoring in critically ill patients. The objective of this trial was to determine the point accuracy and reliability of a device designed for continuous monitoring of interstitial glucose levels in intensive care unit patients. We evaluated point accuracy by comparing device readings with glucose measurements in arterial blood by using blood gas analyzers. Analytical and clinical accuracy was expressed in Bland-Altman plots, glucose prediction errors, and Clarke error grids. We used a linear mixed model to determine which factors affect the point accuracy. In addition, we determined the reliability, including duration of device start-up and calibration, skips in data acquisition, and premature disconnections of sensors. We included 50 patients in whom we used 105 sensors. Five patients from whom we could not collect the predefined minimum number of four consecutive comparative blood draws were excluded from the point accuracy analysis. Therefore, we had 929 comparative samples from 100 sensors in 45 patients (11 (7 to 28) samples per patient) during 4,639 hours (46 (27 to 134) hours per patient and 46 (21 to 69) hours per sensor) for the accuracy analysis. Point accuracy did not meet the International Organization for Standardization (ISO) 14971 standard for insulin dosing accuracy but did improve with increasing numbers of calibrations and was better in patients who did not have a history of diabetes. Out of 105 sensors, 60 were removed prematurely for a variety of reasons. The device start-up time was 49 (43 to 58) minutes. The number of skips in data acquisition was low, resulting in availability of real-time data during 95% (89% to 98%) of the connection time per sensor. The point accuracy of a device designed for continuous real-time monitoring of interstitial glucose levels was relatively low in critically ill patients. The device had few downtimes, but one third of the sensors were removed prematurely because of unresolved sensor- or device-related problems. Netherlands Trial Registry number: NTR3827 . Registered 30 January 201

    Joint EFLM-COLABIOCLI Recommendation for venous blood sampling

    No full text
    This document provides a joint recommendation for venous blood sampling of the European Federation of Clinical Chemistry and Laboratory Medicine (EFLM) Working Group for Preanalytical Phase (WG-PRE) and Latin American Working Group for Preanalytical Phase (WG-PRE-LATAM) of the Latin America Confederation of Clinical Biochemistry (COLABIOCLI). It offers guidance on the requirements for ensuring that blood collection is a safe and patient-centered procedure and provides practical guidance on how to successfully overcome potential barriers and obstacles to its widespread implementation. The target audience for this recommendation are healthcare staff members directly involved in blood collection. This recommendation applies to the use of a closed blood collection system and does not provide guidance for the blood collection with an open needle and syringe and catheter collections. Moreover, this document neither addresses patient consent, test ordering, sample handling and transport nor collection from children and unconscious patients. The recommended procedure is based on the best available evidence. Each step was graded using a system that scores the quality of the evidence and the strength of the recommendation. The process of grading was done at several face-To-face meetings involving the same mixture of stakeholders stated previously. The main parts of this recommendation are: 1) Pre-sampling procedures, 2) Sampling procedure, 3) Post-sampling procedures and 4) Implementation. A first draft of the recommendation was circulated to EFLM members for public consultation. WG-PRE-LATAM was also invited to comment the document. A revised version has been sent for voting on to all EFLM and COLABIOCLI members and has been officially endorsed by 33/40 EFLM and 21/21 COLABIOCLI members. We encourage professionals throughout Europe and Latin America to adopt and implement this recommendation to improve the quality of blood collection practices and increase patient and workers safety

    Raccomandazione congiunta EFLM-COLABIOCLI per il prelievo di sangue venoso : [Joint EFLM-COLABIOCLI recommendation for venous blood sampling]

    No full text
    This document provides a joint recommendation for venous blood sampling of the European Federation of Clinical Chemistry and Laboratory Medicine (EFLM) Working Group for Preanalytical Phase (WG-PRE) and Latin American Working Group for Preanalytical Phase (WG-PRE-LATAM) of the Latin America Confederation of Clinical Biochemistry (COLABIOCLI). It offers guidance on the requirements for ensuring that blood collection is a safe and patient-centered procedure and provides practical guidance on how to successfully overcome potential barriers and obstacles to its widespread implementation. The target audience for this recommendation are healthcare staff members directly involved in blood collection. This recommendation applies to the use of a closed blood collection system and does not provide guidance for the blood collection with an open needle and syringe and catheter collections. Moreover, this document neither addresses patient consent, test ordering, sample handling and transport nor collection from children and unconscious patients. The recommended procedure is based on the best available evidence. Each step was graded using a system that scores the quality of the evidence and the strength of the recommendation. The process of grading was done at several face-to-face meetings involving the same mixture of stakeholders stated previously. The main parts of this recommendation are: 1) Pre-sampling procedures, 2) Sampling procedure, 3) Postsampling procedures and 4) Implementation. A first draft of the recommendation was circulated to EFLM members for public consultation. WG-PRE-LATAM was also invited to comment the document. A revised version has been sent for voting on to all EFLM and COLABIOCLI members and has been officially endorsed by 33/40 EFLM and 21/21 COLABIOCLI members. We encourage professionals throughout Europe and Latin America to adopt and implement this recommendation to improve the quality of blood collection practices and increase patient and workers safety

    Raccomandazione congiunta EFLM-COLABIOCLI per il prelievo di sangue venoso

    No full text
    This document provides a joint recommendation for venous blood sampling of the European Federation of Clinical Chemistry and Laboratory Medicine (EFLM) Working Group for Preanalytical Phase (WG-PRE) and Latin American Working Group for Preanalytical Phase (WG-PRE-LATAM) of the Latin America Confederation of Clinical Biochemistry (COLABIOCLI). It offers guidance on the requirements for ensuring that blood collection is a safe and patient-centered procedure and provides practical guidance on how to successfully overcome potential barriers and obstacles to its widespread implementation. The target audience for this recommendation are healthcare staff members directly involved in blood collection. This recommendation applies to the use of a closed blood collection system and does not provide guidance for the blood collection with an open needle and syringe and catheter collections. Moreover, this document neither addresses patient consent, test ordering, sample handling and transport nor collection from children and unconscious patients. The recommended procedure is based on the best available evidence. Each step was graded using a system that scores the quality of the evidence and the strength of the recommendation. The process of grading was done at several face-to-face meetings involving the same mixture of stakeholders stated previously. The main parts of this recommendation are: 1) Pre-sampling procedures, 2) Sampling procedure, 3) Postsampling procedures and 4) Implementation. A first draft of the recommendation was circulated to EFLM members for public consultation. WG-PRE-LATAM was also invited to comment the document. A revised version has been sent for voting on to all EFLM and COLABIOCLI members and has been officially endorsed by 33/40 EFLM and 21/21 COLABIOCLI members. We encourage professionals throughout Europe and Latin America to adopt and implement this recommendation to improve the quality of blood collection practices and increase patient and workers safety

    Recommandations communes EFLM-COLABIOCLI relatives au prélèvement sanguin veineux

    No full text
    Ce document propose des recommandations pour le prélèvement sanguin veineux. Celles-ci ont été élaborées conjointement par le groupe de travail en charge de la phase pré-analytique (WG-PRE) de la Fédération européenne de chimie clinique et de médecine de laboratoire (EFLM) et le groupe de travail latino-américain pour la phase pré-analytique (WG-PRE-LATAM) de la Confédération latino-américaine de biochimie clinique (COLABIOCLI). Ce document propose des conseils sur les conditions requises permettant de garantir que la prise de sang est une procédure sûre et centrée sur le patient. Il fournit des conseils pratiques sur la manière de surmonter, avec succès, les obstacles potentiels et les barrières à sa mise en œuvre généralisée. Ces recommandations s’adressent aux professionnels de santé directement impliqués dans le prélèvement sanguin. Elles s’appliquent à l’utilisation de système dit « fermé » et ne concernent ni le prélèvement de sang utilisant un dispositif « à écoulement libre », ni les prélèvements à la seringue ou ceux utilisant des cathéters. De plus, ce document ne traite ni du consentement du patient, ni du choix des examens prescrits, ni de la manipulation et du transport des échantillons, ni du prélèvement chez les enfants et les patients inconscients. La procédure recommandée est basée sur les meilleures preuves disponibles. Chaque étape a été pondérée à l’aide d’un système qui évalue le niveau de la preuve et la force de la recommandation. Le processus de notation a été effectué lors de plusieurs réunions impliquant le même groupe d’intervenants qu’indiqué précédemment. Les principaux chapitres de cette recommandation sont les suivants : 1) Procédures précédant le prélèvement, 2) Prélèvement sanguin veineux, 3) Phase post-prélèvement, 4) Mise en œuvre des recommandations. Une première version de ces recommandations a été diffusée aux membres de l’EFLM pour consultation publique. Le WG-PRE-LATAM a également été invité à commenter le document. Une version révisée a été envoyée pour vote à tous les membres de l’EFLM et de COLABIOCLI. Il a été officiellement approuvé par 33 membres sur 40 pour l’EFLM et par 21 membres sur 21 pour COLABIOCLI. Nous encourageons les professionnels à travers l’Europe et l’Amérique latine à adopter et à mettre en œuvre ces recommandations pour améliorer la qualité des pratiques de prélèvements sanguins et pour améliorer la sécurité des patients et du personnel