10 research outputs found

    Urban earthquake hazard and damage assessment

    No full text

    Investigation of the Rail-Induced Vibrations on a Masonry Historical Building

    Get PDF
    Increasingly historic masonry buildings are subjected to higher levels of traffic and rail vibrations due to urbanization and population growth. Deterioration and destabilisation of these buildings may result, especially if they were previously damaged (e.g. earthquakes or settlement problems). To better understand building response, vibration measurements were conducted on the Little Hagia Sophia Mosque, located adjacent to Istanbul’s Sirkeci-Halkali railway line. Transport-induced vibrations were recorded at several points on the ground and building. Attenuation characteristics in the ground and amplification features on the building were examined. Peak particle velocities often exceeded previously established thresholds for human perception and in some cases for structural damage. These are evaluated with respect to the building’s condition.Deposited by bulk impor

    Assessment of Performance of Seismic Isolation System of Bolu Viaduct

    No full text
    The Bolu viaduct is a 2.3-km-long seismically isolated structure that was nearly complete when it was struck by the 1999 Duzce earthquake in Turkey. It suffered complete failure of the seismic isolation system and narrowly avoided total collapse due to excessive superstructure movement. This paper presents an evaluation of the design of the viaduct's seismic isolation system and an assessment of its performance in the Duzce earthquake. Evaluation of the seismic isolation system's design has revealed that it did not meet the requirements of the AASHTO Guide Specifications for Seismic Isolation Design. Analysis of the viaduct with motions scaled in accordance with the AASHTO Guide Specifications resulted in a displacement demand of 820 mm, which is far more than the 210 mm displacement capacity of the existing isolation system. Analysis of the viaduct for a simulated near-fault motion with characteristics consistent with the site conditions resulted in an isolation system displacement demand of 1,400 mm. This indicates that, even if the isolation system had been designed in compliance with the AASHTO, it would have still suffered damage in the earthquake

    Development of earthquake lossmap for Europe

    No full text
    For almost real-time estimation of the losses after a major earthquake in the Euro-Mediterranean region, the Joint Research Area-3 (JRA-3) component of the European Union (EU) Project "Network of Research Infrastructures for European Seismology -NERIES'' foresees (at several levels of sophistication)
    corecore