627 research outputs found

    The RISC-KIT storm impact database: A new tool in support of DRR

    Get PDF
    This paper presents a new storm impact database for European coastlines that facilitates the upload, browsing and download of a broad range of physical and impact information related to historical and recent marine storm events. The database is transparent in terms of open access to raw data and metadata, makes use of version control systems through the OpenEarth repository and promotes the use of international standards. A total of 298 storm events are currently stored in the database from the ten RISC-KIT case study sites, including historical events dating back to the sixteenth century. To demonstrate the application of the tool, examples of typical event data contained within the database as well as the ability of the database to identify impacts of events across regions are presented. It is envisaged that this database will expand beyond the ten case study sites, with the aim of promoting and greatly improving the collection and reporting of extreme hydro-meteorological events across Europe into the future

    Balloon-Expandable TAVR Bioprostheses: Area or Perimeter Sizing? A Prospective Pilot Study.

    Get PDF
    OBJECTIVE: In TAVR, area sizing is used for balloon-expandable (BE) valves, whereas self-expanding valves are sized to annulus perimeter. For BE valves, this seems illogical: these frames force a circular shape even on an ellipsoid annulus. This can potentially lead to relative undersizing when area sizing is being applied. We developed a perimeter-based sizing algorithm to evaluate the safety and feasibility of perimeter sizing for the Myval BE valve. METHODS: In this prospective single-center study, 60 patients with severe aortic stenosis treated with the Myval BE valve were included. Perimeter sizing was used with limited oversizing of 3.7% ± 1.3% compared to the annulus perimeter. After TAVR, clinical outcomes were evaluated at 30 days and 1 year. An echocardiographic follow-up took place at 30 days. RESULTS: At 30 days, the need for PPI and stroke occurred in 2% and 3% of the patients, respectively. Moreover, cardiac death and moderate-severe PVL were absent. At 1-year, cardiac death and stroke were observed in 3% and 8% of the patients, respectively. In 33.3% of the patients, a larger valve size was implanted compared to the valve size calculated by area sizing. CONCLUSIONS: Perimeter sizing with the Myval BE valve leads to substantial use of larger valve sizes and favorable clinical outcomes, with low PPI and the absence of significant PVL. A randomized controlled trial is being planned to prove the superiority of this alternative sizing method

    Argatroban During Percutaneous Transluminal Coronary Angioplasty: Results of a Dose-Verification Study.

    Get PDF
    Background. Thrombin is a key enzyme in thrombogenesis. In animals, specific antithrombotic therapy at the time of coronary angioplasty reduced the incidence of subacute occlusion and inhibited the restenosis response. Argatroban is a highly selective synthetic thrombin antagonist that binds in a competitive manner. This is a report of a dose-verification study, assessing the safety and feasibility of intravenous Argatroban administration in patients undergoing percutaneous transluminal coronary angioplasty. Methods. Before angioplasty an intravenous bolus of 30 g/kg argatroban was administered, followed by a continuous infusion of 3.5 g/kg/min for 72 hours. Bolus injection was repeated, and the infusion rate was increased in order to achieve an activated coagulation time (ACT) of over 300 seconds. Following interim analysis, the bolus and initial infusion rate for the subsequent treatment groups was determined. Study endpoints were the occurrence of adverse events, coagulation tests, and qualitative angiogram reading. Patients were monitored by continuous 12-lead electrocardiographic recording over 24 hours, and underwent control angiography 18–24 hours following angioplasty. Results. Four treatment groups, comprised of 2, 8, 9, and 11 patients, respectively, were studied. The first two patients were excluded from analysis, since the initial dose was ineffective to attain an ACT-authorizing coronary angioplasty. The group with the highest dosage received a 250 g/kg intravenous bolus of argatroban, followed by a 4 hour infusion of 15 g/kg/min. At 4 hours the infusion rate was lowered to 3.8 g/kg/min and was continued for 68 hours without adjustment for catheter removal. The adverse event profile included myocardial infarction, aortocoronary bypass graft, bailout procedures, and repeat coronary angioplasty. Thrombin-time (TT), activated partial thromboplastin time (APTT), and prothrombin time (PT) were significantly related to argatroban plasma concentration, as demonstrated by regression analyses (R-square 0.64, 0.71, and 0.84, respectively). Prothrombin fragments 1 and 2 and thrombin-antithrombin III complex did not fit into a mathematical model, but showed slightly increased levels after reduction or cessation of the infusion rate. Conclusions. This dose-verification study, including 30 patients at four dose levels, indicated that argatroban infusion in coronary angioplasty patients can be administered safely, and results in an adequate and predictable level of anticoagulation

    Improving the accuracy of walking piezo motors

    Get PDF
    Quantum Matter and Optic

    Visual art inspired by the collective feeding behavior of sand-bubbler crabs

    Full text link
    Sand--bubblers are crabs of the genera Dotilla and Scopimera which are known to produce remarkable patterns and structures at tropical beaches. From these pattern-making abilities, we may draw inspiration for digital visual art. A simple mathematical model is proposed and an algorithm is designed that may create such sand-bubbler patterns artificially. In addition, design parameters to modify the patterns are identified and analyzed by computational aesthetic measures. Finally, an extension of the algorithm is discussed that may enable controlling and guiding generative evolution of the art-making process

    Angioscopic versus angiographic detection of initial detection of intimal dissection and intracoronary thrombus

    Get PDF
    AbstractObjectives. This study was undertaken to compare coronary angioscopy with angiography for the detection of intimal dissection and intracoronary thrombus.Background. It has been demonstrated previously that coronary angioscopy provides more intravascular detail than cineangiography. Both imaging methods have to be compared directly to assess the additional diagnostic value of angioscopy.Methods. The angiograms and videotapes of 52 patients who had undergone angioscopy were reviewed independently by two observers unaware of other findings. Classic angiographic definitions were used for dissection and thrombus. Angioscopic dissection was defined as visible cracks or fissures on the lumen surface or mobile protruding structures that are contiguous with the vessel wall. Angioscopic thrombus was defined as a red, white or mixed red and white intraluminal mass.Results. Angiography and angioscopy were in agreement in 40.4% of cases in the absence of thrombus and in 11.5% in the presence of thrombus. No fewer than 25 (48.1%) angioscopically observed thrombi remained undetected at angiography. With angioscopy as the standard, although the specificity of angiography for thrombus was 100%, sensitivity was very low at 19%. Angioscopic dissection was present in 40 patients (76.9%) versus angiographic dissection in 15 patients (28.8%). With regard to dissection, there was no correlation between the two imaging methods (rΦ= 0.15, p = 0.29).Conclusions. Coronary angiography underestimates the presence of intracoronary thrombus. Angioscopy and angiography are complementary techniques for detecting and grading intima1dissections

    Improving the accuracy of walking piezo motors

    Get PDF
    Quantum Matter and Optic

    Positive and negative affect changes during gender-affirming hormonal treatment : results from the European Network for the Investigation of Gender Incongruence (ENIGI)

    Get PDF
    Improving transgender people’s quality of life (QoL) is the most important goal of gender-affirming care. Prospective changes in affect can influence QoL. We aim to assess the impact of initiating gender-affirming hormonal treatment (HT) on affect. In the European Network for the Investigation of Gender Incongruence (ENIGI) study, we prospectively collected data of 873 participants (451 transwomen (TW) and 422 transmen (TM)). At baseline, psychological questionnaires including the Positive and Negative Affect Schedule (PANAS) were administered. The PANAS, levels of sex steroids and physical changes were registered at each follow-up visit during a 3-year follow-up period, starting at the initiation of hormonal therapy. Data were analyzed cross-sectionally and prospectively. Over the first three months, we observed a decline in positive affect (PA) in both TM and TW. Thereafter, PA reached a steady state in TW, whereas in TM there was also a second decline at 18 months. In both TM and TW there was no persisting difference comparing baseline to the 36-months results. Concerning negative affect (NA), we observed a decline during the first year in TM, which sustained during the second year and was not different anymore at 36 months compared to baseline. In TW though, we did not find any change of NA during the entire follow-up. Even if some of these results show significant differences, they should be considered with caution, since there was no control group and the absolute differences are small. No association between affect and the level of sex steroids was observed. Baseline QoL and psychological burden are related to affect independently from gender but are not necessarily good predictors of the evolution of one’s affect during the gender-affirming process. Further research is necessary to investigate these preliminary results

    Serial angioscopic and angiographic observations during the first hour after successful coronary angioplasty: A preamble to a multicenter trial addressing angioscopic markers for restenosis

    Get PDF
    Percutaneous coronary angioscopy was used in 13 patients in a pilot study to assess the intracoronary changes that occur during the first hour after balloon angioplasty (PTCA). The dilated segment was studied with 4.5F angioscopes and with quantitative coronary angiography (QCA) immediately after PTCA and at 15-minute intervals for up to 1 hour after PTCA. Significant progression of intimal dissection and thrombus formation could be demonstrated with angioscopy. These dissections and thrombi remained undetected with angiography, which only showed haziness. Thus th

    Authorship ans aesthetics experiments: comparision of results between human and computational systems

    Get PDF
    [Abstract] This paper presents the results of two experiments comparing the functioning of a computational system and a group of humans when performing tasks related to art and aesthetics. The first experiment consists of the identification of a painting, while the second one uses the Maitland Graves’s aesthetic appreciation test. The proposed system employs a series of metrics based on complexity estimators and low level features. These metrics feed a learning system using neural networks. The computational approach achieves similar results to those achieved by humans, thus suggesting that the system captures some of the artistic style and aesthetics features which are relevant to the experiments performed
    • …
    corecore