35 research outputs found

    POLAR registry (Promus eluting stent registry in Latin America ):1 year follow-up results

    Get PDF
    BACKGROUND: Drug-eluting stents have been used since 2002 in different patient populations aiming to achieve high success rates with low clinical and angiographic restenosis rates. With the late thrombosis adverse events associated to the first generation sirolimus and paclitaxel-eluting stents, second-generation everolimus and zotarolimus-eluting stents has been recently developed. METHODS: The POLAR registry is a prospective, non-randomized, multicenter study, which included 988 patients, totaling 1,362 lesions treated with the everolimus-eluting stent Promus®. In order to represent the clinical practice, almost all subtypes of patients and lesions were included in this registry. Clinical follow-up was planned to be performed 1, 6, 12 and 24 months after the procedure. RESULTS: Most patients were male (69.8%), with mean age of 64.9 ± 9.4 years, 35.2% were diabetics and 55% had been treated for acute coronary syndrome. Vessel diameter was 2.95 ± 0.43 mm and lesion extension was 20.5 ± 5.6 mm. A total of 1.14 ± 0.38 stent/patient were implanted and the procedural success rate was 96.6%. Major adverse cardiac events occurred in 4.5% of patients, and stent thrombosis was observed in 5 patients (0.5%) after a clinical follow-up of 12 months. CONCLUSIONS: The present registry suggests that everolimus-eluting stents are safe and effective in daily clinical practice patients, with a low rate of major adverse cardiac events at the end of the first year of follow-up.INTRODUÇÃO: Desde 2002, os stents farmacológicos são utilizados em diversas populações de pacientes objetivando alcançar elevados índices de sucesso, com baixas taxas de reestenose angiográfica e clínica. Com os resultados adversos em relação à trombose tardia associados aos stents farmacológicos de primeira geração eluidores de sirolimus e paclitaxel, surgiram recentemente os stents farmacológicos de segunda geração eluidores de zotarolimus e everolimus. MÉTODOS: O registro POLAR é um registro prospectivo, não-randomizado, multicêntrico, que incluiu 988 pacientes totalizando 1.362 lesões tratadas com o stent Promus®. Objetivando representar a prática clínica, praticamente todos os subtipos de pacientes e lesões foram incluídos neste registro. O seguimento clínico foi planejado para ser realizado 1 mês, 6 meses, 12 meses e 24 meses após o procedimento. RESULTADOS: A maioria dos pacientes era do sexo masculino (69,8%), com média de idade de 64,9 ± 9,4 anos, 35,2% eram diabéticos e 55% tinham sido tratados na vigência de síndrome coronária aguda. O diâmetro do vaso foi de 2,95 ± 0,43 mm e a extensão da lesão, de 20,5 ± 5,6 mm. Foi implantado 1,14 ± 0,38 stent/paciente e o sucesso do procedimento foi alcançado em 96,6% dos casos. Eventos cardíacos adversos maiores ocorreram em 4,1% dos pacientes, e trombose de stent esteve presente em 5 pacientes (0,5%) após o seguimento clínico de 12 meses. CONCLUSÕES: O presente registro sugere que os stents farmacológicos eluidores de everolimus são seguros e eficazes em pacientes da prática clínica diária, com baixas taxas de eventos cardíacos adversos maiores ao término do primeiro ano de seguimento.Universidade Federal de São Paulo (UNIFESP)Instituto Dante Pazzanese de CardiologiaStatus CorHospital Israelita Albert EinsteinENCORE Hospital Lúcio RebeloReal e Benemérita Associação Portuguesa de BeneficênciaHospital Cardiológico CostantiniHemodinâmica Meridional Intercath MeridionalInstituto de Cardiologia do Espírito SantoFundação Universitária de Cardiologia Instituto de Cardiologia do Rio Grande do SulUNIFESPSciEL

    Expansion of the Multi-Link Frontierâ„¢ Coronary Bifurcation Stent: Micro-Computed Tomographic Assessment in Human Autopsy and Porcine Heart Samples

    Get PDF
    BACKGROUND: Treatment of coronary bifurcation lesions remains challenging, beyond the introduction of drug eluting stents. Dedicated stent systems are available to improve the technical approach to the treatment of these lesions. However dedicated stent systems have so far not reduced the incidence of stent restenosis. The aim of this study was to assess the expansion of the Multi-Link (ML) Frontier™ stent in human and porcine coronary arteries to provide the cardiologist with useful in-vitro information for stent implantation and selection. METHODOLOGY/PRINCIPAL FINDINGS: Nine ML Frontier™ stents were implanted in seven human autopsy heart samples with known coronary artery disease and five ML Frontier™ stents were implanted in five porcine hearts. Proximal, distal and side branch diameters (PD, DD, SBD, respectively), corresponding opening areas (PA, DA, SBA) and the mean stent length (L) were assessed by micro-computed tomography (micro-CT). PD and PA were significantly smaller in human autopsy heart samples than in porcine heart samples (3.54±0.47 mm vs. 4.04±0.22 mm, p = 0.048; 10.00±2.42 mm(2) vs. 12.84±1.38 mm(2), p = 0.034, respectively) and than those given by the manufacturer (3.54±0.47 mm vs. 4.03 mm, p = 0.014). L was smaller in human autopsy heart samples than in porcine heart samples, although data did not reach significance (16.66±1.30 mm vs. 17.30±0.51 mm, p = 0.32), and significantly smaller than that given by the manufacturer (16.66±1.30 mm vs. 18 mm, p = 0.015). CONCLUSIONS/SIGNIFICANCE: Micro-CT is a feasible tool for exact surveying of dedicated stent systems and could make a contribution to the development of these devices. The proximal diameter and proximal area of the stent system were considerably smaller in human autopsy heart samples than in porcine heart samples and than those given by the manufacturer. Special consideration should be given to the stent deployment procedure (and to the follow-up) of dedicated stent systems, considering final intravascular ultrasound or optical coherence tomography to visualize (and if necessary optimize) stent expansion

    Twelve-month clinical and imaging outcomes of the uncaging coronary DynamX bioadaptor system

    No full text
    AIMS: We aimed to assess the safety and efficacy of the DynamX Novolimus-Eluting Coronary Bioadaptor System, a novel device that initially acts as a second-generation drug-eluting stent, but after six months frees the vessel through uncaging elements. METHODS AND RESULTS: This multicentre study enrolled 50 patients with single de novo lesions. In-device acute lumen gain was 1.61±0.34 mm, and device and procedure success was 100%. Up to 12 months, two target lesion failures occurred: both were cardiac deaths (day 255 and day 267 post procedure). No definite or probable device thrombosis was observed. Mean late lumen loss was 0.12±0.18 mm in-device and 0.11±0.16 mm in-segment. Per intravascular ultrasound, the mean device area and mean vessel area increased significantly by 5% and 3%, respectively, while the mean lumen area was maintained. Stationary optical coherence tomography in seven patients demonstrated restoration of cyclic pulsatility, with an approximate lumen area variance of 11% between systole and diastole. CONCLUSIONS: The DynamX bioadaptor showed drug-eluting stent-like acute performance and safety and efficacy up to one year. Positive remodelling with an increase of vessel and device area while maintaining the mean lumen area was demonstrated. Long-term follow-up and randomised trials are required to assess the benefit of this device on events beyond one year.status: publishe
    corecore