706 research outputs found

    In-vivo, cardiac-cycle related intimal displacement of coronary plaques assessed by 3-D ECG-gated intravascular ultrasound: Exploring its correlate with tissue deformability identified by palpography

    Get PDF
    Background: ECG-gated image acquisition of intravascular ultrasound (IVUS) has been shown to provide more accurate measurements at different phases of the cardiac cycle. Objective: We sought to explore the ability dynamic assessment of ECG-gated 3-D IVUS to identify deformable regions of coronary plaques, by testing the hypothesis that at a given pressure and region, a faster displacement of the intima would correspond to high strain (soft tissue) regions assessed by palpography. Methods: ECG-gated 3-D IVUS and palpograms were acquired using 30 and 20 MHz IVUS imaging catheters respectively. Frames with high and/or low strain spots identified by palpography were randomly selected and the spots were assigned to a respective quadrant within the cross section. A color-blinded side-by-side view was performed to enable the co-localization of the same region. Subsequently, the pressure driven displacement of the intima was established for each quadrant and a binary score (significant displacement or no displacement) was decided. Results: One hundred and twenty-four quadrants were studied and the prevalence of highly deformable quadrants was low (n=7, 5.6% of the total). The sensitivity, specificity, positive predictive value and negative predictive value of 3-D ECG-gated IVUS to detect deformable quadrants as assessed by palpography were 42.9, 87.2, 16.7, and 96.2% respectively. Conclusion: In this pilot in vivo study, the intimal displacement velocity in the radial direction assessed by gray-scale 3-D ECG-gated IVUS failed to correlate with highly deformable regions. However, these preliminary findings suggest that the absence of significant displacement of the intima might be accurate to predict the absence of deformable tissue

    Long-term fluvastatin reduces the hazardous effect of renal impairment on four-year atherosclerotic outcomes (a LIPS substudy)

    Full text link
    peer reviewedMild renal impairment is an important risk factor for late cardiovascular complications. This substudy of the Lescol Intervention Prevention Study (LIPS) assessed the effect of fluvastatin on outcome of patients who had renal dysfunction and those who did not. Complete data for creatinine clearance calculation. (Cockcroft=Gault formula) were available for 1,558 patients (92.9% of the LIPS population). Patients were randomized to fluvastatin or placebo after successful completion of a first percutaneous coronary intervention. Follow-up time was, 3 to 4 years. The effect of baseline creatinine clearance on coronary atherosclerotic events (cardiac death, non-fatal myocardial infarction, and coronary reinterventions not related to restenosis) was evaluated. Baseline creatinine clearance (logarithmic transformation) was inversely associated with an incidence of adverse events among patients who received, placebo. (hazard ratio 0.99, 95% confidence interval 0.982 to 0.998, p = 0.01). However, no association was noted between creatinine clearance and the incidence of adverse events among patients who received fluvastatin (hazard ratio 1.0, 95% confidence interval 0.99 to 1.0, p = 0.63). No further deterioration in creatinine clearance was observed during follow-up; regardless of baseline renal function or allocated treatment. Occurrence of adverse events was not related to changes in renal function during follow-up. Fluvastatin therapy markedly decreased the risk of coronary atherosclerotic events after percutaneous intervention in: patients who had lower values of creatinine clearance at baseline: The benefit of fluvastatin was unrelated to any effect on renal function. (C) 2005 by Excerpta Medica Inc

    Nanoparticle formation and dynamics in a complex (dusty) plasma: from the plasma ignition to the afterglow.

    Get PDF
    Complex (dusty) plasmas are a subject of growing interest. They areionized gases containing charged dust particles. In capacitively-coupled RF discharges, dust growth can occur naturally and two methods can be used to grow dust particles: chemically active plasmas or sputtering. The growth of dust particles in argon discharges by RF sputtering and the effect of dust particles on theplasma have been investigated from the plasma ignition to the afterglow. It was shown that plasma and discharge parameters are greatly affected by the dust particles. Furthermore, plasma instabilities can be triggered by the presence of the dust particles. These instabilities can be due to dust particle growth or they can be instabilities of a well established dust cloud filling the interelectrode space. When the discharge is switched off, the dust particles act like a sink for the charge carrier and consequently affect the plasma losses. It was shown that the dust particles do keep residual chargeswhich values are greatly affected by the diffusion of the charge carriers and especially the transition from ambipolar to free diffusion

    Angiographic, ultrasonic, and angioscopic assessment of the coronary artery wall and lumen area configuration after directional atherectomy: the mechanism revisited.

    Get PDF
    The purpose of the present study was to use the complementary information of angiography, intravascular ultrasound, and intracoronary angioscopy before and after directional atherectomy to characterize the postatherectomy appearance of vessel wall contours and the mechanism of lumen enlargement. Directional coronary atherectomy aims at debulking rather than dilating a coronary artery lesion. The selective removal of the plaque may potentially minimize the vessel wall damage and lead to subsequent better late outcome. Whether plaque removal is the main mechanism of action has only to be assessed indirectly by angiography and warrants further investigation with detailed analysis of luminal changes and vessel wall damage by ultrasound and direct visualization with angioscopy. Twenty-six patients have been investigated by quantitative angiography, intravascular ultrasound, and intracoronary angioscopy (n = 19) before and after atherectomy. In addition, all retrieved specimens were microscopically examined. Ultrasound imaging showed an increase in lumen area from 1.95 Ā± 0.70 mm2 to 7.86 Ā± 2.16 mm2 at atherectomy. The achieved gain mainly resulted from plaque removal because plaque plus media area decreased from 18.16 Ā± 4.47 mm2 to 13.13 Ā± 3.10 mm2. Vessel wall stretching (i.e., change in external elastic lamina area) accounted for only 15% of lumen area gain. Luminal gain was higher in noncalcified (6.52 Ā± 2.12 mm2) lesions than in lesions containing deeply located calcium (5.19 Ā± 0.99 mm2) and lowest in superficially calcified lesions (5.41 Ā± 2.41 mm2). Ultrasound imaging identified an atherectomy byte in 85% of the cases, whereas angioscopy revealed such a crevice in 74%. The complementary use of the three techniques revealed an underestimation of the presence of dissection/tear and new thrombus by angiography (10% and 4%) and ultrasound imaging (12% and 0%) compared with angioscopy (26% and 21%). The combined use of angiography, ultrasound, and angioscopy reveals that the postatherectomy luminal lining is not as regular and smooth as that seen by angiography. Luminal enlargement with atherectomy is achieved by plaque excision rather than arterial expansion

    Diagnostic accuracy of multislice computed tomography coronary angiography is improved at low heart rates

    Get PDF
    Purpose: Assess the effect of heart rate on diagnostic accuracy for the detection of significant coronary artery stenosis using 16-row multislice computed tomography (MSCT). Material and methods: About 120 patients (105 males; 59 Ā± 11 years) with suspected coronary artery disease who underwent conventional coronary angiography (CA) and MSCT-CA were retrospectively enrolled for the study. Patients underwent a MSCT-CA (Sensation 16, Siemens, Germany), with the following protocol: Collimation 16 Ɨ 0.75 mm, gantry rotation time 420 ms, feed/rotation 3.0 mm, kV 120, mAs 400-500. The protocol for contrast material administration was 100 ml of Iodixanol (Visipaque 320 mg l/ml, Amersham, UK) at 4 ml/s and the delay was defined with a bolus tracking technique. In all patients the mean heart rate (HR) during the scan was used as a criteria to divide the population in two groups of 60 patients each. In one group (Low HR) the 60 patients with lower heart rates, and in the other group (High HR) the patients with higher heart rates. In the two groups diagnostic accuracy (per coronary segment) for the detection of significant stenosis (ā‰„50% lumen reduction) was evaluated in vessels ā‰„2 mm of diameter using quantitative CA as reference standard. The difference in diagnostic accuracy were compared with a Chi2 test and a p < 0.05 was considered significant. Results: There was no significant difference between the two groups regarding age, gender, weight, mean intravascular attenuation, and calcium score. Overall 1310 (652 for Low HR and 658 for High HR) segments with 219 (105 for Low HR and 114 for High HR) significant lesions were available for the analysis. The average heart rate was 52 Ā± 4HU and 63 Ā± 5HU for Low HR and High HR, respectively (p < 0.001). The sensitivity and specificity were 92 and 96% for Low HR and 90 and 92% for High HR (p < 0.05). There were 22 vs. 44 false positives, and 8 vs. 12 false negatives in the Low HR and High HR, respectively. Conclusion: Increasing HR significantly deteriorates diagnostic accuracy in MSCT-CA

    Small coronary calcifications are not detectable by 64-slice contrast enhanced computed tomography

    Get PDF
    Recently, small calcifications have been associated with unstable plaques. Plaque calcifications are both in intravascular ultrasound (IVUS) and multi-slice computed tomography (MSCT) easily recognized. However, smaller calcifications might be missed on MSCT due to its lower resolution. Because it is unknown to which extent calcifications can be detected with MSCT, we compared calcification detection on contrast enhanced MSCT with IVUS. The coronary arteries of patients with myocardial infarction or unstable angina were imaged by 64-slice MSCT angiography and IVUS. The IVUS and MSCT images were registered and the arteries were inspected on the presence of calcifications on both modalities independently. We measured the length and the maximum circumferential angle of each calcification on IVUS. In 31 arteries, we found 99 calcifications on IVUS, of which only 47 were also detected on MSCT. The calcifications missed on MSCT (nĀ =Ā 52) were significantly smaller in angle (27Ā°Ā Ā±Ā 16Ā° vs. 59Ā°Ā Ā±Ā 31Ā°) and length (1.4Ā Ā±Ā 0.8 vs. 3.7Ā Ā±Ā 2.2Ā mm) than those detected on MSCT. Calcifications could only be detected reliably on MSCT if they were larger than 2.1Ā mm in length or 36Ā° in angle. Half of the calcifications seen on the IVUS images cannot be detected on contrast enhanced 64-slice MSCT angiography images because of their size. The limited resolution of MSCT is the main reason for missing small calcifications

    Diagnosis of an Intracoronary Thrombus With Intravascular Ultrasound

    Get PDF
    A60-year-old man was referred for coronary angiography because of exertional angina (Canadian Cardiovascular Society angina classification type II). Twelve years earlier, he had had a myocardial infarction with a venous bypass graft to the right coronary artery
    • ā€¦
    corecore