Evaluation of the ADVIA (R) Centaur (TM) TSH-3 assay
An analytical evaluation of the thyroid stimulating hormone (TSH-3) assay on the Sayer ADVIA(R) Centaur(TM) immunoassay system was performed. General analytical requirements (linearity, resistance to typical interferences, absence of a carry-over effect) were fulfilled and reproducibility was satisfactory. Inter-assay coefficient of variation (CV) of a human serum pool with a concentration of 0.014 mU/l was 22.3%; at concentrations between 0.26 and 83 mU/l CV was below 6%. Method comparison study demonstrated close agreement of TSH results compared to those obtained with the Roche Elecsys(R) 2010 TSH assay (ADVIA Centaur = 1.08 x Elecsys - 0.18 mU/l; r = 0.987; n = 324). Handling and practicability of the ADVIA Centaur system proved to be convenient with a very high sample throughput. We conclude that the ADVIA Centaur TSH-3 assay meets requirements for clinical use
Calcitonin Response to Naturally Occurring Ionized Hypercalcemia in Cats with Chronic Kidney Disease.
BACKGROUND: Hypercalcemia is commonly associated with chronic kidney disease (CKD) in cats. OBJECTIVES: To explore the calcitonin response to naturally occurring ionized hypercalcemia in cats with azotemic CKD, and to assess the relationship of plasma calcitonin with ionized calcium, alkaline phosphatase (ALP), and urinary calcium excretion. ANIMALS: Thirty-three client-owned cats with azotemic CKD and ionized hypercalcemia from first opinion practice. METHODS: Cohort study. Calcitonin was measured with an immunoradiometric assay in heparinized plasma. Simple correlations were assessed with Kendall's rank correlation, and the within-subject correlations of calcitonin with ionized calcium and other clinicopathological variables were calculated with a bivariate linear mixed effects model. RESULTS: Calcitonin concentrations above the lower limit of detection (>1.2 pg/mL; range, 1.7-87.2 pg/mL) were observed in 11 of 33 hypercalcemic cats (responders). Blood ionized calcium concentration did not differ significantly between responders (median, 1.59 [1.46, 1.66] mmol/L) and nonresponders (median, 1.48 [1.43, 1.65] mmol/L; P = 0.22). No evidence was found for calcitonin and ionized calcium to correlate between cats (τb  = 0.14; P = 0.31; n = 33), but significant positive correlation was evident within individual responders over time (within-subject correlation coefficient [rwithin ], 0.83; 95% confidence interval [CI], 0.63-0.92). Calcitonin correlated negatively over time with plasma ALP (rwithin , -0.55; 95% CI, -0.79 to -0.16). CONCLUSIONS AND CLINICAL IMPORTANCE: Calcitonin does not appear to have an important role in calcium metabolism in cats with CKD
A systematic review of the literature examining the diagnostic efficacy of measurement of fractionated plasma free metanephrines in the biochemical diagnosis of pheochromocytoma
BACKGROUND: Fractionated plasma metanephrine measurements are commonly used in biochemical testing in search of pheochromocytoma. METHODS: We aimed to critically appraise the diagnostic efficacy of fractionated plasma free metanephrine measurements in detecting pheochromocytoma. Nine electronic databases, meeting abstracts, and the Science Citation Index were searched and supplemented with previously unpublished data. Methodologic and reporting quality was independently assessed by two endocrinologists using a checklist developed by the Standards for Reporting of Diagnostic Studies Accuracy Group and data were independently abstracted. RESULTS: Limitations in methodologic quality were noted in all studies. In all subjects (including those with genetic predisposition): the sensitivities for detection of pheochromocytoma were 96%–100% (95% CI ranged from 82% to 100%), whereas the specificities were 85%–100% (95% CI ranged from 78% to 100%). Statistical heterogeneity was noted upon pooling positive likelihood ratios when those with predisposition to disease were included (p < 0.001). However, upon pooling the positive or negative likelihood ratios for patients with sporadic pheochromocytoma (n = 191) or those at risk for sporadic pheochromocytoma (n = 718), no statistical heterogeneity was noted (p = 0.4). For sporadic subjects, the pooled positive likelihood ratio was 5.77 (95% CI = 4.90, 6.81) and the pooled negative likelihood ratio was 0.02 (95% CI = 0.01, 0.07). CONCLUSION: Negative plasma fractionated free metanephrine measurements are effective in ruling out pheochromocytoma. However, a positive test result only moderately increases suspicion of disease, particularly when screening for sporadic pheochromocytoma
Les manuscrits de la Bibliotheque royale de Bruxelles.
Extrait du Tone 24 des bull. de la soc. hist. et litt, de Tournai.LEIDSSTELSELOPLADEN-RUG0
Elections d'eveques a Tournai au. Moyen-Age (1274-1484).
CHECK1890LEIDSSTELSELOPLADEN-RUG0
Etude du ratio procalcitonine/calcitonine dans les cancers médullaires de la thyroïde
LILLE2-BU Santé-Recherche (593502101) / SudocSudocFranceF
- …