39 research outputs found

    Microwave Imaging Reflectometry Experiment in TPE-RX

    Get PDF
    Microwave imaging reflectometry (MIR) was developed in TPE-RX, one of the world’s largest reversed field pinch (RFP) devices. The system optics are made of aluminum mirrors, Teflon lenses, and Plexiglas plates in order to reduce size. In this system, frequencies are stabilized so that noise can be reduced using narrow bandpass filters. A 4×4 2-D mixer array and phase detection system have also been developed. With this system, density fluctuations in the high-Θ RFP plasma, pulsed poloidal current drive (PPCD) plasma, and quasi-single helicity(QSH) plasma are observed in TPE-RX. This is the first MIR experiment in an RFP device

    Reply for the comment

    No full text

    Study of turbulence in a reversed field pinch plasma by microwave imaging reflectometry

    No full text
      The physics of turbulence is a key to understand the plasma confinement. In the reversed-field pinch (RFP) plasma, turbulence plays an important role to sustain the RFP configuration. However, the experimental study of the turbulence is not sufficient especially around the field reversal surface in the case of RFP plasma. Microwave imaging reflectometry (MIR) is expected to be a powerful tool for the turbulence measurement, because it provides the direct view of the 2D/3D image of the turbulence near the cutoff surface deeply into plasma. However, the turbulence study by using MIR has not been reported yet. This work presents the turbulence measurement around the reversal field surface in a large RFP device TPE-RX by using MIR.  In RFP, the reversed toroidal field in the edge region is sustained by the dynamo, which is driven by instabilities and turbulence. RFP also has an MHD turbulence suppression technique: the pulsed poloidal current drive (PPCD) operation. The MHD dynamo theory predicts that the fluctuations in the flow (v~) and the magnetic field (B~) form the equilibrium electromotive force (EMF)~×B~|, where | denotes parallel to the magnetic field (it is poloidal at the reversal surface). Without PPCD operation, the ohm’s law is written as: ηJ|=~×B~| . The dynamo ~×B~| can drive the poloidal current, which generates the reversed toroidal field. The PPCD operation generates the external electric field E|. In this case, the ohm\u27s law is written as ηJ|=E|+ ~×B~|. The poloidal current is directly driven by E| without the help of the dynamo. As a result, the fluctuations in the PPCD plasma may be suppressed. So far various candidates for the RFP turbulence have been discussed: tearing instabilities, interchange instabilities and drift wave turbulence. Nevertheless, a definitive explanation still lacks. Therefore, comparison the turbulence around the field reversal surface between plasmas with PPCD and without PPCD may clarify the turbulence physics in the RFP plasma.  MIR is one of the new diagnostics to measure the 2D/3D density fluctuations. It is based on the microwave reflection at the density-dependent cutoff surface. MIR signal can be written as Aeiφ, where A is the amplitude and is the phase. The amplitudeA is measured by a diode detector.The phase is measured by a quadrature (IQ) detector, as φ=arctan(Q/I), where I=cosφ, and Q=sinφ. In order to investigate the principles of MIR measurement, comparison between the simulation and a laboratory test of the MIR system has been carried out. The numerical model based on the Huygens-Fresnel equation is used to simulate the MIR signal. In this test, we found that φ corresponds to the displacement of the cutoff surface in the radial direction, and A corresponds to the reflection power, which is modulated by the shape of the cutoff surface. From the simulation and laboratory test, MIR is valid with the condition 4kδL/D to measure the motion of the cutoff surface. Here D is the diameter of the optical lens. L is the distance between the cutoff surface and the optical lens. k and δ are the perpendicular wavenumber and the radial displacement of the fluctuation, respectively. The measured fluctuations in TPE-RX plasmas mainly distribute in the range of 4kδL/D  TPE-RX is one of the world largest RFP devices, which was built in National Institute of Advanced Industrial Science and Technology (AIST), Tsukuba, Japan, and it has the major and the minor radii of R=1.72m and a=0.45m, respectively. All discharges in this work have the plasma density in the range of (0.5~1.0)×1019 m-3 and the plasma current in the range of 200~300 kA. In order to measure the density fluctuations around the reversal surface (r/a=0.7~0.9) in TPE-RX, we have developed a MIR system with the microwave frequency of 20 GHz (O-mode, the cutoffdensity is 0.5×1019 m-3) and a 4 × 4 Yagi-Uda antenna array. In this system, the spatial resolution is 3.7 cm and the temporal resolution is 1μs.  Analysis techniques, which have been developed to study the turbulence in this work, are as follows: (1) the cross correlation, (2) the wavelet, (3) the maximum entropy method (MEM), (4) the fluctuation distributions (skewness and kurtosis), and (5) the bicoherence. The skewness and kurtosis are used to quantify the distribution of the fluctuations. By using wavelet analysis, the short-lived turbulent structures can be observed. The wavelet bicoherence is used to quantify the nonlinear interaction. The maximum entropy method (MEM) is useful to estimate the high resolution 2Dk spectrum.  The observed features of the RFP turbulence around the field reversal surface in this work are as follows: (1) In the low k and the low frequency ranges, the MIR signal has a high correlation with the magnetic fluctuations. Without PPCD operation, the m=0 tearing modes (may be dynamo) are dominant. On the other hand, the m=1 tearing modes are dominant in the PPCD plasma.(2) In the high k and the high frequency ranges, MIR signal has a high correlation with the electrostatic fluctuations measured by the Langmuir probe. The k spectrum is broad and is shifted in the electron drift direction in the plasma without PPCD. The high nonlinear coupling between the high k modes and the low kmodes is observed. While in the PPCD plasma, the high k mode has not been observed.(3) The intermittency is increased as the reversal parameter |F| is increased in the case of without PPCD. (Note: the reversal parameter F = Bt(a)/t> can be used to identify the strength of the dynamo as the reversed toroidal field Bt(a) is mainly sustained by the dynamo. The deep F plasma corresponds to the strong dynamo.) The intermittency corresponds to the bursts of the negative spikes in MIR signal, which has a small-scale structure with high fluctuation amplitude. In the PPCD plasma, the intermittency is not observed and the confinement is improved as the soft-X-ray is increased by the factor of 100. The fluctuations around the field reversal surface are probably caused by the resistive interchange instabilities, because the high frequency fluctuations have the features of electrostatic turbulence, while the low frequency fluctuations are dominated by the low k tearing modes. The high nonlinear coupling between the high k modes and the low k modes in the plasma without PPCD suggests that the dynamo and the electrostatic-like turbulence are correlated. The high intermittency at deep F plasma is expected to be partly driven by the nonlinear interaction between electrostatic-like turbulence. Simulation of MIR signal suggests that the intermittency in MIR signal is caused by the blob structure, which scatters the reflected wave and leads to the rapid decrease of the reflected power (negative spike). This enhances the transport and decreases the confinement.   In conclusion, this work is the first demonstration of MIR as the turbulence diagnostics. This is the first observation of the turbulence around the field reversal surface in RFP plasma. This work demonstrates how the dynamo and intermittent structures cause bad confinement

    Compaction and Breakage Characteristics of Crushed Stone Used as the Backfill Material of Urban Pavement Subsidence

    No full text
    The subsidence of urban pavement is becoming frequent accidents, and backfill is the primary means of remedy. Crushed stone is a commonly used aggregate for backfill material in engineering, and its compaction behavior under load needs to be well understood. In this work, a series of compaction tests were carried out on the same batch of crushed stone samples with the same gradation. The content changes of particles with different sizes were analyzed, the particle breakage characteristics during the compaction process were discussed, and the difference in particle breakage caused by loading speed and loading mode was examined. It shows the following: (1) For all samples, the content of particles that were crushed during compaction was always less than 40%. The particles with the strongest breakage varied with sample gradation. (2) The particle breakage could be divided into four categories: complete fragmentation, complete rupture, local fragmentation, and surface grinding. They affected the particle size distribution after compaction to varying degrees. (3) The particle breakage could be expressed as a cubical parabola of loading speed, whose coefficients are related to the sample gradation. (4) Stepwise loading rendered stronger particle breakage than direct loading, and the increase of particle breakage due to loading mode was more evident for continuous grading samples than discontinuous grading samples. This study will provide an experimental basis and reference for the selection and use of backfill aggregate in urban subsidence areas

    Upgrade of the relative calibration methods and Bayesian inference processing for electron cyclotron emission radiometry

    No full text
    An upgraded local oscillator (LO) hopping calibration method based on a blackbody hot source and a perturbation analysis of the magnetic field difference method are introduced in this work. The blackbody hot source is used to evaluate the difference in the relative coefficients between the two LO hopping frequencies in the same channels. Then the coefficients are obtained by multiplying the LO hopping frequencies coefficients by LO hopping calibration coefficients. In this way, it is more flexible and stable than the in-situ calibration. The magnetic field difference method provides another calibration method to obtain the relative calibration coefficients of the electron cyclotron emission radiometers (ECE). In general, the magnetic field difference method needs two similar shots but with a difference of 2.1% (for HL-2M) in the magnetic field. Meanwhile, there are some errors because of the deviation of detection positions in the same channels between the two shots. For evaluating the calibration errors, the impact of the displacement, Te perturbation of the core region, and magnetic field difference has been discussed. The result shows that a larger magnetic field difference can improve the accuracy of the calibration. In the end, Bayesian inference has been utilized to evaluate the calibration coefficients and get the most probable calibration coefficients along with its the confidence interval
    corecore