15 research outputs found

    Probing Dark Matter with Adaptive-optics based Flux Ratio Anomalies: Photometric and Astrometric Precision

    Full text link
    Strong gravitational lensing is a powerful probe of the distribution of matter on sub-kpc scales. It can be used to test the existence of completely dark subhalos surrounding galaxies, as predicted by the standard cold dark matter model, or to test alternative dark matter models. The constraining power of the method depends strongly on photometric and astrometric precision and accuracy. We simulate and quantify the capabilities of upcoming adaptive optics systems and advanced instruments on ground-based telescopes, focusing as an illustration on the Keck Telescope (OSIRIS + KAPA, LIGER + KAPA) and the Thirty Meter Telescope (TMT; IRIS + NFIRAOS). We show that these new systems will achieve dramatic improvements over current ones in both photometric and astrometric precision. Narrow line flux ratio errors below 2%2\%, and submilliarcsecond astrometric precision will be attainable for typical quadruply imaged quasars. With TMT, the exposure times required will be of order a few minutes per system, enabling the follow-up of 100-1000 systems expected to be discovered by the Rubin, Euclid, and Roman Telescopes.Comment: 14 pages, 10 figure

    Mapping our Universe in 3D with MITEoR

    Full text link
    Mapping our universe in 3D by imaging the redshifted 21 cm line from neutral hydrogen has the potential to overtake the cosmic microwave background as our most powerful cosmological probe, because it can map a much larger volume of our Universe, shedding new light on the epoch of reionization, inflation, dark matter, dark energy, and neutrino masses. We report on MITEoR, a pathfinder low-frequency radio interferometer whose goal is to test technologies that greatly reduce the cost of such 3D mapping for a given sensitivity. MITEoR accomplishes this by using massive baseline redundancy both to enable automated precision calibration and to cut the correlator cost scaling from N^2 to NlogN, where N is the number of antennas. The success of MITEoR with its 64 dual-polarization elements bodes well for the more ambitious HERA project, which would incorporate many identical or similar technologies using an order of magnitude more antennas, each with dramatically larger collecting area.Comment: To be published in proceedings of 2013 IEEE International Symposium on Phased Array Systems & Technolog

    Brute-Force Mapmaking with Compact Interferometers: A MITEoR Northern Sky Map from 128 MHz to 175 MHz

    Get PDF
    We present a new method for interferometric imaging that is ideal for the large fields of view and compact arrays common in 21 cm cosmology. We first demonstrate the method with the simulations for two very different low-frequency interferometers, the Murchison Widefield Array and the MIT Epoch of Reionization (MITEoR) experiment. We then apply the method to the MITEoR data set collected in 2013 July to obtain the first northern sky map from 128 to 175 MHz at ∼2° resolution and find an overall spectral index of −2.73 ± 0.11. The success of this imaging method bodes well for upcoming compact redundant low-frequency arrays such as Hydrogen Epoch of Reionization Array. Both the MITEoR interferometric data and the 150 MHz sky map are available at http://space.mit.edu/home/tegmark/omniscope.html.National Science Foundation (U.S.) (AST-0908848)National Science Foundation (U.S.) (AST-1105835)National Science Foundation (U.S.) (AST-1440343

    Mapping our universe in 3D with MITEoR

    Get PDF
    Mapping our universe in 3D by imaging the redshifted 21 cm line from neutral hydrogen has the potential to overtake the cosmic microwave background as our most powerful cosmological probe, because it can map a much larger volume of our Universe, shedding new light on the epoch of reionization, inflation, dark matter, dark energy, and neutrino masses. We report on MITEoR, a pathfinder low-frequency radio interferometer whose goal is to test technologies that greatly reduce the cost of such 3D mapping for a given sensitivity. MITEoR accomplishes this by using massive baseline redundancy both to enable automated precision calibration and to cut the correlator cost scaling from N[superscript 2] to N log N, where N is the number of antennas. The success of MITEoR with its 64 dual-polarization elements bodes well for the more ambitious HERA project, which incorporates many identical or similar technologies using an order of magnitude more antennas, each with dramatically larger collecting area.National Science Foundation (U.S.) (Grant AST-0908848)National Science Foundation (U.S.) (Grant AST-1105835)MIT Kavli Instrumentation FundMassachusetts Institute of Technology. Undergraduate Research Opportunities Progra

    Systematic error mitigation for the PIXIE Fourier transform spectrometer

    No full text
    International audienceThe Primordial Inflation Explorer (PIXIE) is an Explorer-class mission concept to measure the spectrum and polarization of the cosmic microwave background. Cosmological signals are small compared to the instantaneous instrument noise, requiring strict control of instrumental signals. The instrument design provides multiple levels of null operation, signal modulation, and signal differences, with only few-percent systematic error suppression required at each level. Jackknife tests based on discrete instrument symmetries provide an independent means to identify, model, and remove remaining instrumental signals. We use detailed time-ordered simulations, including realistic performance and tolerance parameters, to evaluate the instrument response to broad classes of systematic errors for both spectral distortions and polarization. The largest systematic errors contribute additional white noise at the few-percent level compared to the dominant photon noise. Coherent instrumental effects which do not integrate down are smaller still, and remain several orders of magnitude below the targeted cosmological signals

    Systematic error mitigation for the PIXIE Fourier transform spectrometer

    No full text
    International audienceThe Primordial Inflation Explorer (PIXIE) is an Explorer-class mission concept to measure the spectrum and polarization of the cosmic microwave background. Cosmological signals are small compared to the instantaneous instrument noise, requiring strict control of instrumental signals. The instrument design provides multiple levels of null operation, signal modulation, and signal differences, with only few-percent systematic error suppression required at each level. Jackknife tests based on discrete instrument symmetries provide an independent means to identify, model, and remove remaining instrumental signals. We use detailed time-ordered simulations, including realistic performance and tolerance parameters, to evaluate the instrument response to broad classes of systematic errors for both spectral distortions and polarization. The largest systematic errors contribute additional white noise at the few-percent level compared to the dominant photon noise. Coherent instrumental effects which do not integrate down are smaller still, and remain several orders of magnitude below the targeted cosmological signals

    MITEoR: a scalable interferometer for precision 21 cm cosmology

    Get PDF
    We report on the MIT Epoch of Reionization (MITEoR) experiment, a pathfinder low-frequency radio interferometer whose goal is to test technologies that improve the calibration precision and reduce the cost of the high-sensitivity 3D mapping required for 21 cm cosmology. MITEoR accomplishes this by using massive baseline redundancy, which enables both automated precision calibration and correlator cost reduction. We demonstrate and quantify the power and robustness of redundancy for scalability and precision. We find that the calibration parameters precisely describe the effect of the instrument upon our measurements, allowing us to form a model that is consistent with χ[superscript 2] per degree of freedom <1.2 for as much as 80 per cent of the observations. We use these results to develop an optimal estimator of calibration parameters using Wiener filtering, and explore the question of how often and how finely in frequency visibilities must be reliably measured to solve for calibration coefficients. The success of MITEoR with its 64 dual-polarization elements bodes well for the more ambitious Hydrogen Epoch of Reionization Array project and other next-generation instruments, which would incorporate many identical or similar technologies
    corecore