273 research outputs found

    A Novel Extraction Procedure of Contact Characteristic Parameters from Current–Voltage Curves in CdZnTe and CdTe Detectors

    Get PDF
    The estimation of the characteristic parameters of the electrical contacts in CdZnTe and CdTe detectors is related to the identification of the main transport mechanisms dominating the currents. These investigations are typically approached by modelling the current–voltage (I–V) curves with the interfacial layer–thermionic-diffusion (ITD) theory, which incorporates the thermionic emission, diffusion and interfacial layer theories into a single theory. The implementation of the ITD model in measured I–V curves is a critical procedure, requiring dedicated simplifications, several best fitting parameters and the identification of the voltage range where each transport mechanism dominates. In this work, we will present a novel method allowing through a simple procedure the estimation of some characteristic parameters of the metal–semiconductor interface in CdZnTe and CdTe detectors. The barrier height and the effects of the interfacial layer will be evaluated through the application of a new function related to the differentiation of the experimental I–V curves

    Grown and artificial mosaic GaAs crystals for hard X-ray astronomy

    Get PDF
    In order to increase the collection efficiency of a lens for hard X-ray energies, mosaic GaAs crystals to be used as optic elements in Laue diffraction are proposed. In fact, GaAs crystals show a natural degree of mosaicity due to the spontaneous formation during the growth of cellular structures with dislocations at the boundaries. Several GaAs samples grown by LEC method have been characterized by means of high-resolution X-ray diffraction. Mosaicity values ranging from 10 to 25 arcsec have been measured. Since proper growth conditions allow to control and modify both the dislocation density and the cellular structure responsible of the mosaic spread, the possibility of obtaining crystals with a given degree of mosaicity by tuning the LEC growth conditions is proposed. A complementary strategy to increase the Darwin width of the diffraction curve based on curved crystals has also been proposed. The lattice curvature was achieved by introducing a compressive stress on the crystal surface. Curvature radii between 2 and 8m were easily obtained in wafer crystals 500 μm thick

    Análisis y ejecución de estrategias en la industria de sensores mediante la simulación CAPSIM

    Get PDF
    Documento en el que se muestra el trabajo realizado en la dirección de una empresa de la industria de sensores dentro del simulador de negocios Capsim. Se presenta un análisis de la industria de los sensores, se describe la empresa en la que se trabajó, las estrategias de negocio y el proceso de su implementación, así como los resultados finales

    Design and advancement status of the Beam Expander Testing X-ray facility (BEaTriX)

    Full text link
    The BEaTriX (Beam Expander Testing X-ray facility) project is an X-ray apparatus under construction at INAF/OAB to generate a broad (200 x 60 mm2), uniform and low-divergent X-ray beam within a small lab (6 x 15 m2). BEaTriX will consist of an X-ray source in the focus a grazing incidence paraboloidal mirror to obtain a parallel beam, followed by a crystal monochromation system and by an asymmetrically-cut diffracting crystal to perform the beam expansion to the desired size. Once completed, BEaTriX will be used to directly perform the quality control of focusing modules of large X-ray optics such as those for the ATHENA X-ray observatory, based on either Silicon Pore Optics (baseline) or Slumped Glass Optics (alternative), and will thereby enable a direct quality control of angular resolution and effective area on a number of mirror modules in a short time, in full X-ray illumination and without being affected by the finite distance of the X-ray source. However, since the individual mirror modules for ATHENA will have an optical quality of 3-4 arcsec HEW or better, BEaTriX is required to produce a broad beam with divergence below 1-2 arcsec, and sufficient flux to quickly characterize the PSF of the module without being significantly affected by statistical uncertainties. Therefore, the optical components of BEaTriX have to be selected and/or manufactured with excellent optical properties in order to guarantee the final performance of the system. In this paper we report the final design of the facility and a detailed performance simulation.Comment: Accepted paper, pre-print version. The finally published manuscript can be downloaded from http://dx.doi.org/10.1117/12.223895

    Temperature study of Al0.52In0.48P detector photon counting X-ray spectrometer

    Get PDF
    A prototype 200 μm diameter Al0.52In0.48P p+-i-n+ mesa photodiode (2 μm i-layer) was characterised at temperatures from 100 °C to −20 °C for the development of a temperature tolerant photon counting X-ray spectrometer. At each temperature, X-ray spectra were accumulated with the AlInP detector reverse biased at 0 V, 5 V, 10 V, and 15 V and using different shaping times. The detector was illuminated by an 55Fe radioisotope X-ray source. The best energy resolution, as quantified by the full width at half maximum (FWHM) at 5.9 keV, was observed at 15 V for all the temperatures studied; at 100 °C, a FWHM of 1.57 keV was achieved, and this value improved to 770 eV FWHM at −20 °C. System noise analysis was also carried out, and the different noise contributions were computed as functions of temperature. The results are the first demonstration of AlInP's suitability for photon counting X-ray spectroscopy at temperatures other than ≈20 °C

    Advances in High-Energy-Resolution CdZnTe Linear Array Pixel Detectors with Fast and Low Noise Readout Electronics

    Get PDF
    Radiation detectors based on Cadmium Zinc Telluride (CZT) compounds are becoming popular solutions thanks to their high detection efficiency, room temperature operation, and to their reliability in compact detection systems for medical, astrophysical, or industrial applications. However, despite a huge effort to improve the technological process, CZT detectors’ full potential has not been completely exploited when both high spatial and energy resolution are required by the application, especially at low energies (<10 keV), limiting their application in energy-resolved photon counting (ERPC) systems. This gap can also be attributed to the lack of dedicated front-end electronics which can bring out the best in terms of detector spectroscopic performances. In this work, we present the latest results achieved in terms of energy resolution using SIRIO, a fast low-noise charge sensitive amplifier, and a linear-array pixel detector, based on boron oxide encapsulated vertical Bridgman-grown B-VB CZT crystals. The detector features a 0.25-mm pitch, a 1-mm thickness and is operated at a −700-V bias voltage. An equivalent noise charge of 39.2 el. r.m.s. (corresponding to 412 eV FWHM) was measured on the test pulser at 32 ns peaking time, leading to a raw resolution of 1.3% (782 eV FWHM) on the 59 keV line at room temperature (+20 °C) using an uncollimated 241Am, largely improving the current state of the art for CZT-based detection systems at such short peaking times, and achieving an optimum resolution of 0.97% (576 eV FWHM) at 1 µs peaking time. The measured energy resolution at the 122 keV line and with 1 µs peaking time of a 57Co raw uncollimated spectrum is 0.96% (1.17 keV). These activities are in the framework of an Italian collaboration on the development of energy-resolved X-ray scanners for material recycling, medical applications, and non-destructive testing in the food industry

    High performance platinum contacts on high-flux CdZnTe detectors

    Get PDF
    The need for direct X-ray detection under high photon flux with moderate or high energies (30–100 keV range) has strongly increased with the rise of the 4th Generation Synchrotron Light Sources, characterised by extremely brilliant beamlines, and of other applications such as spectral computed tomography in medicine and non-destructive tests for industry. The novel Cadmium Zinc Telluride (CZT) developed by Redlen Technologies can be considered the reference material for high-flux applications (HF-CZT). The enhanced charge transport properties of the holes allow the mitigation of the effects of radiation induced polarization phenomena, typically observed in standard CZT materials (LF-CZT) under high photon flux. However, standard LF-CZT electrical contacts led to inacceptable high dark leakage currents on HF-CZT devices. In this work, a detailed study on the characteristics of new optimized sputtered platinum electrical contacts on HF-CZT detectors is reported. The results from electrical and spectroscopic investigations, showed the best performances on HF-CZT detectors with platinum anode, coupled with both platinum or gold cathode. The morphology, structure, and composition of Pt/CZT contact have been analysed by means of Transmission Electron Microscopy (TEM) on microscopic lamellas obtained by Focused Ion Beam (FIB), highlighting the presence of CdTeO3 oxide at the metal semiconductor interface

    Window-Based Energy Selecting X-ray Imaging and Charge Sharing in Cadmium Zinc Telluride Linear Array Detectors for Contaminant Detection

    Get PDF
    The spectroscopic and imaging performance of energy-resolved photon counting detectors, based on new sub-millimetre boron oxide encapsulated vertical Bridgman cadmium zinc telluride linear arrays, are presented in this work. The activities are in the framework of the AVATAR X project, planning the development of X-ray scanners for contaminant detection in food industry. The detectors, characterized by high spatial (250 µm) and energy (<3 keV) resolution, allow spectral X-ray imaging with interesting image quality improvements. The effects of charge sharing and energy-resolved techniques on contrast-to-noise ratio (CNR) enhancements are investigated. The benefits of a new energy-resolved X-ray imaging approach, termed window-based energy selecting, in the detection of low- and high-density contaminants are also shown

    Laser-induced transient currents in CdZnTe quasi-hemispherical radiation detector

    Get PDF
    Laser-induced transient currents were measured after applying pulsed or direct-current bias to a CdZnTe quasi-hemispherical radiation detector with gold contacts. The temporal evolution of current transients was analyzed to evaluate the dynamics of the space charge formation and its spatial distribution. The observed effects were explained by a model involving hole injection from positively biased contacts. Experimental results were complemented by numerical simulations, which supported the model. This paper discusses how the detected phenomena affect the detector performance and proposes an improved detector design
    corecore