219 research outputs found

    Continuous arterial spin labeling (CASL) in the monkey brain at high magnetic field using a three-coil approach

    Get PDF
    CASL experiments in the monkey brain were performed at 4.7 T and 7 T using a separate labeling coil. Increased sensitivity and SNR were achieved by a custom-made three-coil setup and high magnetic field with its increased T1. We report the development and optimization of the setup and first experiments in the monkey (macaca mulatta). Parameters for continuous labeling (label power, label duration, post label delay) were optimized to measure gray matter rCBF and fCBF changes, reporting excellent multi-slice coverage at high resolution of 0.75 – 1 mm in-plane

    Perfusion-based functional imaging in the monkey brain at 7T: investigations of CASL parameters

    Get PDF
    Perfusion-based imaging in the monkey primary visual cortex was performed at 7 T applying continuous arterial spin labeling (CASL). Increased perfusion sensitivity and SNR at high magnetic field (due to larger T1) was further optimized using a custom-made three-coil setup with a separate neck labeling coil. We investigated the labeling parameters to obtain relative fCBF changes in the anaesthetized monkey. We report excellent functional activation of striate cortex at high resolution of 0.75x0.9mm2 in-plane. Interestingly, the optimal parameter set for obtaining highest signal changes of rCBF are different from the reported values for imaging gray matter CBF

    Dextran as internal calibrant for N-glycan analysis by liquid chromatography coupled to ion mobility-mass spectrometry

    Get PDF
    LC–MS is one of the most important tools for the comprehensive characterization of N-glycans. Despite many efforts to speed up glycan analysis via optimized sample preparation (e.g., faster enzyme digestion in combination with instant or rapid labeling dyes), a major bottleneck remains the rather long measurement times of HILIC chromatography. Further compli- cation arises from the necessity to concomitantly calibrate with an external standard to allow for accurate retention times and the conversion into more robust GU values. Here we demonstrate the use of an internal calibration strategy for HILIC chromatography to speed up glycan analysis. By reducing the number of utilized dextran oligosaccharides, the calibrant can be spiked directly into the sample such that external calibration runs are no longer required. The minimized dextran ladder shows accurate GU calibration with a minor deviation of well below 1% and can be applied without modifications in sample preparation or data processing. We further demonstrate the simultaneous use of the minimized dextran ladder as calibrant for the estimation of CCS values in traveling wave ion mobility spectrometry. In both cases, the minimized dextran ladder enables the measurement of calibrant and sample in a single HPLC run without losing information or accuracy

    Fiske steps and hysteresis in YBa2Cu3O7 grain boundary Josephson junctions: Structural Information of the barrier by means of a nondestructive approach.

    Get PDF
    A deep analysis of the current-voltage _I-V_ characteristics of YBa2Cu3O7 grain boundary Josephson junctions _GBJJs_ allows us to go much farther than the usual calculus of the transport parameters. It is possible to construct a structural image of the barrier by an exhaustive and complementary analysis of both transport and electromagnetic parameters obtained from I-V curves. For such an approach, we have chosen the following three representative bicrystalline geometries: 24° _001_ asymmetric, 45° _100_ asymmetric, and 24° _001_ symmetric +45° _100_ asymmetric. The dependence of the product ICRN on the junction normal resistance is of the ICRN −1 type pointing to a SNINS model _S denotes superconductor, I denotes insulator, and N denotes normal metal_ for all our GBJJs. A satisfactory explanation of the discrepancy of the capacitance of the barrier estimated from Fiske resonance positions and hysteresis in the I-V curves needs of such a model. Moreover an estimation of the length of the normal regions adjacent to the crystallographic barrier can be made. This comparative analysis is presented in order to extract interesting information about the particular transport mechanisms involved in these GBJJs

    Four-port coupled channel-guide device based on 2D photonic crystal structure

    No full text
    We have fabricated and measured a four-port coupled channel-waveguide device using W1 channel waveguides oriented along ΓK directions in a two-dimensional (2D) hole-based planar photonic crystal (PhC) based on silicon-on-insulator (SOI) waveguide material, at operation wavelengths around 1550 nm. 2D FDTD simulations and experimental results are shown and compared. The structure has been designed using a mode conversion approach, combined with coupled-mode concepts. The overall length of the photonic crystal structure is typically about 39 ÎŒm and the structure has been fabricated using a combination of direct-write electron-beam lithography (EBL) and dry-etch processing. Devices were measured using a tunable laser with end-fire coupling into the planar structure

    Rationale and study design of the Prospective comparison of Angiotensin Receptor neprilysin inhibitor with Angiotensin receptor blocker MEasuring arterial sTiffness in the eldERly (PARAMETER) study.

    Get PDF
    Hypertension in elderly people is characterised by elevated systolic blood pressure (SBP) and increased pulse pressure (PP), which indicate large artery ageing and stiffness. LCZ696, a first-in-class angiotensin receptor neprilysin inhibitor (ARNI), is being developed to treat hypertension and heart failure. The Prospective comparison of Angiotensin Receptor neprilysin inhibitor with Angiotensin receptor blocker MEasuring arterial sTiffness in the eldERly (PARAMETER) study will assess the efficacy of LCZ696 versus olmesartan on aortic stiffness and central aortic haemodynamics

    Resonant Steps in the Characteristics of a Josephson Junction Coupled to a Transmission Line

    Get PDF
    A novel circuit is described which functions as an electronic analog of lumped element transmission line. The circuit requires only operational amplifiers, resistors, and capacitors. This module was coupled to a Josephsonj unction simulator and current voltage characteristics of the combined system were recorded. Steps were observed at voltages determined by the appropriate line resonances. When the transmission line was terminated with loads less than the characteristic impedance, chaos was seen in the lower steps. Similar results were obtained by numerical integration of the corresponding system of differential equations
    • 

    corecore