    Evaluation of peak inspiratory pressure, tidal volume and respiratory rate during ventilation of premature lambs using a self-inflating bag

    Get PDF
    OBJECTIVE: To evaluate the peak inspiratory pressure, tidal volume and respiratory rate achieved during manual ventilation of premature lambs, using a self-inflating bag. METHODS: In this descriptive, experimental study, five pairs of physicians, selected at random among 35 neonatologists working at a neonatal intensive care unit and with experience in the resuscitation of newborn infants, ventilated five intubated premature lambs using a self-inflating bag. Pressure and flow monitor signals were passed through a transducer and digitized for recording and analysis. Tidal volume and pressure curves were obtained from the integral of flow rate, at peak, during the last 50 seconds of every fifth minute, and analyzed. RESULTS: Median pressure was 39.8 (IQ25-75% 30.2-47.2) cmH2O; being below 20 in 1.1% of cases and above 40 in 49.1%. Seven out of 10 physicians produced more than six pressure peaks of over 40 cmH2O. Median tidal volume/kg was 17.8 (IQ25-75% 14.1-22.4) mL, being below 5 mL in 0.1% of cases and greater than or equal to 20 mL in 37.7%. All of the physicians propelled five or more ventilation cycles with tidal volume/kg of 20 mL or more. Respiratory rate was between 30 and 60 cycles/minute in 65.9% of cases, being below 30 in 6.8% of cases and over 60 in 27.3% of cases. CONCLUSIONS: There was major variation in peak inspiratory pressure and tidal volume/kg values, which were in many cases elevated, attaining levels that habitually cause biotrauma, while respiratory rates were adequate in the majority of cases.OBJETIVO: Avaliar o pico de pressão inspiratória, o volume corrente e a freqüência respiratória obtidos durante ventilação manual de carneiros prematuros, utilizando balão auto-inflável. MÉTODOS: Estudo experimental descritivo em que cinco duplas de médicos selecionados aleatoriamente entre 35 neonatologistas que trabalham em unidade de terapia intensiva neonatal e experientes em reanimação de recém-nascidos ventilaram cinco carneiros prematuros intubados, utilizando balão auto-inflável. Os sinais de pressão e fluxo eram captados, convertidos por meio de transdutores e digitalizados para armazenamento e análise. Foram avaliadas curvas de pressão e de volume corrente, este a partir da integral do fluxo, em suas medidas de pico, nos 50 segundos finais de cada 5 minutos. RESULTADOS: A mediana da pressão foi de 39,8 (IQ25-75% 30,2-47,2) cmH2O; foi menor que 20 em 1,1% das vezes e maior que 40 em 49,1%. Sete em 10 médicos propiciaram mais de seis picos de pressão maiores que 40 cmH2O. A mediana do volume corrente/kg foi de 17,8 (IQ25-75% 14,1-22,4) mL, sendo menor que 5 mL em 0,1% das vezes e igual ou maior que 20 mL em 37,7%. Todos os médicos impuseram cinco ou mais ciclos ventilatórios com volume corrente/kg de 20 mL ou mais. A freqüência situou-se entre 30 e 60 ciclos/minuto em 65,9% das vezes, sendo menor que 30 em 6,8% e maior que 60 em 27,3% das vezes. CONCLUSÃO: Ocorreu grande variabilidade nos valores do pico de pressão inspiratória e do volume corrente/kg, sendo muitas vezes elevados e alcançando níveis indutores de biotrauma; para a freqüência respiratória, os valores foram adequados na maioria das vezes.Universidade de BrasíliaUnBUniversidade Federal de São Paulo (UNIFESP)UnB Hospital Universitário da UnBUniversidade de São Paulo Faculdade de Medicina Instituto da Criança do Hospital das ClínicasUNIFESPSciEL

    Evaluation of peak inspiratory pressure and respiratory rate during ventilation of an infant lung model with a self-inflating bag

    Get PDF
    OBJETIVO: Avaliar o pico de pressão inspiratória e a freqüência ventilatória obtidos por médicos quando da utilização de balão auto-inflável neonatal em modelo de pulmão. MÉTODOS: Quinze médicos ventilaram simuladores de pulmão de recém-nascidos a termo e pré-termo, sendo os desfechos captados através de um monitor de ventilação. RESULTADOS: As medianas dos picos de pressão foram 23 (intervalo interquartil, 15-47) e 26 (intervalo interquartil, 14-51) cmH2O, sendo menor que 20 em 41,2 e 35,8% das vezes; maior que 40 em 29,7 e 33,6% das vezes e entre 27 e 33 cmH2O em 8,2 e 6,5% das vezes, para o pulmão de termo e de pré-termo, respectivamente. As medianas das freqüências ventilatórias foram de 45 (intervalo interquartil, 36-57) e 48 (intervalo interquartil, 39-55,5) ciclos por minuto, sendo menor que 30 em 9,3 e 6,7% das vezes e maior que 60 em 12 e 13,3% das vezes, respectivamente, para o pulmão de termo e de pré-termo. As diferenças nas medianas não foram estatisticamente significantes. CONCLUSÃO: A ventilação utilizando o balão auto-inflável promoveu adequação para a freqüência ventilatória em aproximadamente 80% das vezes, e os médicos não conseguiram promover ventilação com mínima variabilidade na pressão, alcançando níveis diferentes daqueles definidos no curso de reanimação neonatal em 70% das vezes. Essa situação independeu da ventilação do pulmão-teste análogo ao sistema respiratório de recém-nascidos a termo ou pré-termo.OBJECTIVE: To evaluate the peak inspiratory pressure and ventilation rate achieved by physicians when using a neonatal self-inflating bag on a lung model. METHODS: Fifteen physicians ventilated full term and preterm infant lung simulators while the outcomes were captured by a ventilation monitor. RESULTS: Median peak pressures in cmH2O for full term and preterm lungs were 23 (interquartile range: 15-47) and 26 (interquartile range: 14-51), being less than 20 in 41.2 and 35.8% of the pressure curves analyzed, more than 40 in 29.7 and 33.6%, and between 27 and 33 cmH2O in 8.2 and 6.5% of the curves, respectively. Median ventilation rates were 45 (interquartile range: 36-57) and 48 (interquartile range: 39-55.5) cycles per minute, being more than 30 in 9.3 and 6.7% of pressure curves and more than 60 in 12 and 13.3% of pressure curves, for the full term and preterm lungs, respectively. The differences between these medians were not statistically significant. CONCLUSIONS: Ventilation rates achieved with the self-inflating bag were adequate in approximately 80% of pressure curves analyzed, but the physicians were unable to provide ventilation with minimal pressure variation, producing pressures that diverged from those defined by the neonatal resuscitation training course in 70% of the curves. This was irrespective of whether they were ventilating the lung model analogous to preterm or full term infant lungs

    Postpartum psychiatric disorders

    Get PDF
    Pregnancy is a complex and vulnerable period that presents a number of challenges to women, including the development of postpartum psychiatric disorders (PPDs). These disorders can include postpartum depression and anxiety, which are relatively common, and the rare but more severe postpartum psychosis. In addition, other PPDs can include obsessive–compulsive disorder, post-traumatic stress disorder and eating disorders. The aetiology of PPDs is a complex interaction of psychological, social and biological factors, in addition to genetic and environmental factors. The goals of treating postpartum mental illness are reducing maternal symptoms and supporting maternal–child and family functioning. Women and their families should receive psychoeducation about the illness, including evidence-based discussions about the risks and benefits of each treatment option. Developing effective strategies in global settings that allow the delivery of targeted therapies to women with different clinical phenotypes and severities of PPDs is essential

    Avaliação do pico de pressão, do volume corrente e da freqüência respiratória durante ventilação de carneiros prematuros utilizando balão auto-inflável Evaluation of peak inspiratory pressure, tidal volume and respiratory rate during ventilation of premature lambs using a self-inflating bag

    No full text
    OBJETIVO: Avaliar o pico de pressão inspiratória, o volume corrente e a freqüência respiratória obtidos durante ventilação manual de carneiros prematuros, utilizando balão auto-inflável. MÉTODOS: Estudo experimental descritivo em que cinco duplas de médicos selecionados aleatoriamente entre 35 neonatologistas que trabalham em unidade de terapia intensiva neonatal e experientes em reanimação de recém-nascidos ventilaram cinco carneiros prematuros intubados, utilizando balão auto-inflável. Os sinais de pressão e fluxo eram captados, convertidos por meio de transdutores e digitalizados para armazenamento e análise. Foram avaliadas curvas de pressão e de volume corrente, este a partir da integral do fluxo, em suas medidas de pico, nos 50 segundos finais de cada 5 minutos. RESULTADOS: A mediana da pressão foi de 39,8 (IQ25-75% 30,2-47,2) cmH2O; foi menor que 20 em 1,1% das vezes e maior que 40 em 49,1%. Sete em 10 médicos propiciaram mais de seis picos de pressão maiores que 40 cmH2O. A mediana do volume corrente/kg foi de 17,8 (IQ25-75% 14,1-22,4) mL, sendo menor que 5 mL em 0,1% das vezes e igual ou maior que 20 mL em 37,7%. Todos os médicos impuseram cinco ou mais ciclos ventilatórios com volume corrente/kg de 20 mL ou mais. A freqüência situou-se entre 30 e 60 ciclos/minuto em 65,9% das vezes, sendo menor que 30 em 6,8% e maior que 60 em 27,3% das vezes. CONCLUSÃO: Ocorreu grande variabilidade nos valores do pico de pressão inspiratória e do volume corrente/kg, sendo muitas vezes elevados e alcançando níveis indutores de biotrauma; para a freqüência respiratória, os valores foram adequados na maioria das vezes.<br>OBJECTIVE: To evaluate the peak inspiratory pressure, tidal volume and respiratory rate achieved during manual ventilation of premature lambs, using a self-inflating bag. METHODS: In this descriptive, experimental study, five pairs of physicians, selected at random among 35 neonatologists working at a neonatal intensive care unit and with experience in the resuscitation of newborn infants, ventilated five intubated premature lambs using a self-inflating bag. Pressure and flow monitor signals were passed through a transducer and digitized for recording and analysis. Tidal volume and pressure curves were obtained from the integral of flow rate, at peak, during the last 50 seconds of every fifth minute, and analyzed. RESULTS: Median pressure was 39.8 (IQ25-75% 30.2-47.2) cmH2O; being below 20 in 1.1% of cases and above 40 in 49.1%. Seven out of 10 physicians produced more than six pressure peaks of over 40 cmH2O. Median tidal volume/kg was 17.8 (IQ25-75% 14.1-22.4) mL, being below 5 mL in 0.1% of cases and greater than or equal to 20 mL in 37.7%. All of the physicians propelled five or more ventilation cycles with tidal volume/kg of 20 mL or more. Respiratory rate was between 30 and 60 cycles/minute in 65.9% of cases, being below 30 in 6.8% of cases and over 60 in 27.3% of cases. CONCLUSIONS: There was major variation in peak inspiratory pressure and tidal volume/kg values, which were in many cases elevated, attaining levels that habitually cause biotrauma, while respiratory rates were adequate in the majority of cases