20 research outputs found

    Use of antibiotics by primary care doctors in Hong Kong

    Get PDF
    © 2009 Lam et al; licensee BioMed Central Ltd. This is an Open Access article distributed under the terms of the Creative Commons Attribution Licens

    Clinical and biomechanical outcome of minimal invasive and open repair of the Achilles tendon

    Get PDF
    Introduction: With evolutions in surgical techniques, minimally invasive surgical (MIS) repair with Achillon applicator has been introduced. However, there is still a lack of literature to investigate into the clinical merits of MIS over open surgery. This study aims to investigate the correlation between clinical outcome, gait analysis and biomechanical properties comparing both surgical methods.Materials and methods: A single centre retrospective review on all the consecutive operated patients between January 2004 and December 2008 was performed. Twenty-six patients (19 male and 7 female; age 40.4 ± 9.2 years) had experienced a complete Achilles tendon rupture with operative repair. Nineteen of the patients, 10 MIS versus 9 open repairs (13 men with a mean age of 40.54 ± 10.43 (range 23-62 yrs) and 6 women with a mean age of 45.33 ± 7.71 (range 35-57 yrs) were further invited to attend a thorough clinical assessment using Holz's scale and biomechanical evaluation at a mean of 25.3 months after operation. This study utilized the Cybex II isokinetic dynamometer to assess the isokinetic peak force of plantar-flexion and dorsiflexion of both ankles. The patients were also invited to return to our Gait Laboratory for analysis. The eight-infrared camera motion capture system (VICON, UK) was utilized for the acquisition of kinematic variables. Their anthropometric data was measured according to the Davis and coworkers' standard.Results: The mean operative time and length of hospital stay were shorter in the MIS group. The operative time was 54.55 ± 15.15 minutes versus 68.80 ± 18.23 minutes of the MIS group and Open group respectively (p = 0.045), whereas length of stay was 3.36 ± 1.21 days versus 6.40 ± 3.70 days respectively (p = 0.039). There is statistically significant decrease (p = 0.005) in incision length in MIS group than the open surgery group, 3.23 ± 1.10 cm versus 9.64 ± 2.55 cm respectively. Both groups attained similar Holz's scores, 11.70 ± 0.95 versus 12.0 ± 1.50 respectively (p = 0.262). The mean percentage stance time of the injured leg for MIS patient was 58.44% while the mean percentage stance time of the injured leg for patients with open repair was 56.57%. T-test has shown there were no significance differences between the results of the two groups of patients. The loss of peak torque and total work done with respect to the injured side were similar between the MIS and open group.Discussion and conclusion: MIS using Achillon method can achieve smaller incisions, shorter operative time and hospital stay. There is no statistical significance difference in clinical outcome, the stance time to strike time ratio and biomechanical properties on the leg receiving Achilles tendon repair using MIS method and open surgery. © 2011 Chan et al; licensee BioMed Central Ltd

    Clinical and biomechanical outcome of minimal invasive and open repair of the Achilles tendon

    Get PDF
    Introduction: With evolutions in surgical techniques, minimally invasive surgical (MIS) repair with Achillon applicator has been introduced. However, there is still a lack of literature to investigate into the clinical merits of MIS over open surgery. This study aims to investigate the correlation between clinical outcome, gait analysis and biomechanical properties comparing both surgical methods.Materials and methods: A single centre retrospective review on all the consecutive operated patients between January 2004 and December 2008 was performed. Twenty-six patients (19 male and 7 female; age 40.4 ± 9.2 years) had experienced a complete Achilles tendon rupture with operative repair. Nineteen of the patients, 10 MIS versus 9 open repairs (13 men with a mean age of 40.54 ± 10.43 (range 23-62 yrs) and 6 women with a mean age of 45.33 ± 7.71 (range 35-57 yrs) were further invited to attend a thorough clinical assessment using Holz's scale and biomechanical evaluation at a mean of 25.3 months after operation. This study utilized the Cybex II isokinetic dynamometer to assess the isokinetic peak force of plantar-flexion and dorsiflexion of both ankles. The patients were also invited to return to our Gait Laboratory for analysis. The eight-infrared camera motion capture system (VICON, UK) was utilized for the acquisition of kinematic variables. Their anthropometric data was measured according to the Davis and coworkers' standard.Results: The mean operative time and length of hospital stay were shorter in the MIS group. The operative time was 54.55 ± 15.15 minutes versus 68.80 ± 18.23 minutes of the MIS group and Open group respectively (p = 0.045), whereas length of stay was 3.36 ± 1.21 days versus 6.40 ± 3.70 days respectively (p = 0.039). There is statistically significant decrease (p = 0.005) in incision length in MIS group than the open surgery group, 3.23 ± 1.10 cm versus 9.64 ± 2.55 cm respectively. Both groups attained similar Holz's scores, 11.70 ± 0.95 versus 12.0 ± 1.50 respectively (p = 0.262). The mean percentage stance time of the injured leg for MIS patient was 58.44% while the mean percentage stance time of the injured leg for patients with open repair was 56.57%. T-test has shown there were no significance differences between the results of the two groups of patients. The loss of peak torque and total work done with respect to the injured side were similar between the MIS and open group.Discussion and conclusion: MIS using Achillon method can achieve smaller incisions, shorter operative time and hospital stay. There is no statistical significance difference in clinical outcome, the stance time to strike time ratio and biomechanical properties on the leg receiving Achilles tendon repair using MIS method and open surgery. © 2011 Chan et al; licensee BioMed Central Ltd

    A comparative study on the indoor thermal comfort and energy consumption of typical public rental housing types under near-extreme summer conditions in Hong Kong

    Get PDF
    © 2017 The Authors. Published by Elsevier Ltd. Residents of the dense urban environment in Hong Kong suffer from poor living conditions due to building overheating, especially during near-extreme summer conditions. In this study, the thermal comfort and energy performance of typical public rental housing (PRH) building types were simulated using DesignBuilder. Results show that the oldest Slab type PRH, which has a compact building form, has the highest indoor air temperature, yet the lowest cooling energy demand. On the other hand, the Trident type PRH, with the largest external wall U-value, performs the worst overall and is the most responsive to outdoor temperature changes

    Sequential algorithm to stratify liver fibrosis risk in overweight/obese metabolic dysfunction-associated fatty liver disease

    Get PDF
    BackgroundNon-diabetic overweight/obese metabolic dysfunction-associated fatty liver disease (MAFLD) represents the largest subgroup with heterogeneous liver fibrosis risk. Metabolic dysfunction promotes liver fibrosis. Here, we investigated whether incorporating additional metabolic risk factors into clinical evaluation improved liver fibrosis risk stratification among individuals with non-diabetic overweight/obese MAFLD.Materials and methodsComprehensive metabolic evaluation including 75-gram oral glucose tolerance test was performed in over 1000 participants from the New Hong Kong Cardiovascular Risk Factor Prevalence Study (HK-NCRISPS), a contemporary population-based study of HK Chinese. Hepatic steatosis and fibrosis were evaluated based on controlled attenuation parameter and liver stiffness (LS) measured using vibration-controlled transient elastography, respectively. Clinically significant liver fibrosis was defined as LS ≥8.0 kPa. Our findings were validated in an independent pooled cohort comprising individuals with obesity and/or polycystic ovarian syndrome.ResultsOf the 1020 recruited community-dwelling individuals, 312 (30.6%) had non-diabetic overweight/obese MAFLD. Among them, 6.4% had LS ≥8.0 kPa. In multivariable stepwise logistic regression analysis, abnormal serum aspartate aminotransferase (AST) (OR 7.95, p<0.001) and homeostasis model assessment of insulin resistance (HOMA-IR) ≥2.5 (OR 5.01, p=0.008) were independently associated with LS ≥8.0 kPa, in a model also consisting of other metabolic risk factors including central adiposity, hypertension, dyslipidaemia and prediabetes. A sequential screening algorithm using abnormal AST, followed by elevated HOMA-IR, was developed to identify individuals with LS ≥8.0 kPa, and externally validated with satisfactory sensitivity (>80%) and negative predictive value (>90%).ConclusionA sequential algorithm incorporating AST and HOMA-IR levels improves fibrosis risk stratification among non-diabetic overweight/obese MAFLD individuals

    The Effects of Occupy Central on Hong Kong Tourism

    No full text

    REACH2-Mote: a range-extending passive wake-up wireless sensor node

    Get PDF
    A wireless sensor network that employs passive radio wake-up of the sensor nodes can reduce the energy cost for unnecessary idle listening and communication overhead, extending the network lifetime. A passive wake-up radio is powered by the electromagnetic waves transmitted by a wake-up transmitter rather than a battery on the sensor node. However, this method of powering the wake-up radio results in a short wake-up range, which limits the performance of a passive wake-up radio sensor network. In this article, we describe our design of a passive wake-up radio sensor node-REACH2-Mote-using a high-efficiency, energy-harvesting module and a very low power wake-up circuit to achieve an extended wake-up range. We implemented REACH2-Mote in hardware and performed field tests to characterize its performance. The experimental results show that REACH2-Mote can achieve a wake-up range of 44 feet. We also modeled REACH2-Mote and evaluated its performance through simulations, comparing its performance to that of another passive wake-up radio approach, an active wake-up radio approach, and a conventional duty cycling approach. The simulation results show that REACH2-Mote can significantly extend the network lifetime while achieving high packet delivery rate and low latency.Peer Reviewe
    corecore