50 research outputs found

    中心静脈栄養施行中の突然死の一例

    Get PDF

    An artifice in the insertion of the Hickman catheter in small children

    Get PDF
    Although the Hickman catheter is commonly used in pediatric patients, it is difficult to place this catheter safely in small children, especially infants. A multiple-step method, starting with a thinner catheter, makes the placement easier and safer.Keywords: central venous catheter, children, Hickman cathete

    Investigation of the feasibility of a simple method for verifying the motion of a binary multileaf collimator synchronized with the rotation of the gantry for helical tomotherapy

    Get PDF
    In this paper, we suggest a new method for verifying the motion of a binary multileaf collimator (MLC) in helical tomotherapy. For this we used a combination of a cylindrical scintillator and a general-purpose camcorder. The camcorder records the light from the scintillator following photon irradiation, which we use to track the motion of the binary MLC. The purpose of this study is to demonstrate the feasibility of this method as a binary MLC quality assurance (QA) tool. First, the verification was performed using a simple binary MLC pattern with a constant leaf open time; secondly, verification using the binary MLC pattern used in a clinical setting was also performed. Sinograms of simple binary MLC patterns, in which leaves that were open were detected as "open" from the measured light, define the sensitivity which, in this case, was 1.000. On the other hand, the specificity, which gives the fraction of closed leaves detected as "closed", was 0.919. The leaf open error identified by our method was -1.3 +/- 7.5%. The 68.6% of observed leaves were performed within +/- 3% relative error. The leaf open error was expressed by the relative errors calculated on the sinogram. In the clinical binary MLC pattern, the sensitivity and specificity were 0.994 and 0.997, respectively. The measurement could be performed with -3.4 +/- 8.0% leaf open error. The 77.5% of observed leaves were performed within +/- 3% relative error. With this method, we can easily verify the motion of the binary MLC, and the measurement unit developed was found to be an effective QA tool.ArticleJOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS. 13(1):27-43 (2012)journal articl

    Investigation of the feasibility of a simple method for verifying the motion of a binary multileaf collimator synchronized with the rotation of the gantry for helical tomotherapy

    Get PDF
    In this paper, we suggest a new method for verifying the motion of a binary multileaf collimator (MLC) in helical tomotherapy. For this we used a combination of a cylindrical scintillator and a general-purpose camcorder. The camcorder records the light from the scintillator following photon irradiation, which we use to track the motion of the binary MLC. The purpose of this study is to demonstrate the feasibility of this method as a binary MLC quality assurance (QA) tool. First, the verification was performed using a simple binary MLC pattern with a constant leaf open time; secondly, verification using the binary MLC pattern used in a clinical setting was also performed. Sinograms of simple binary MLC patterns, in which leaves that were open were detected as "open" from the measured light, define the sensitivity which, in this case, was 1.000. On the other hand, the specificity, which gives the fraction of closed leaves detected as "closed", was 0.919. The leaf open error identified by our method was -1.3 +/- 7.5%. The 68.6% of observed leaves were performed within +/- 3% relative error. The leaf open error was expressed by the relative errors calculated on the sinogram. In the clinical binary MLC pattern, the sensitivity and specificity were 0.994 and 0.997, respectively. The measurement could be performed with -3.4 +/- 8.0% leaf open error. The 77.5% of observed leaves were performed within +/- 3% relative error. With this method, we can easily verify the motion of the binary MLC, and the measurement unit developed was found to be an effective QA tool.ArticleJOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS. 13(1):27-43 (2012)journal articl

    DOCK2 is involved in the host genetics and biology of severe COVID-19

    Get PDF
    「コロナ制圧タスクフォース」COVID-19疾患感受性遺伝子DOCK2の重症化機序を解明 --アジア最大のバイオレポジトリーでCOVID-19の治療標的を発見--. 京都大学プレスリリース. 2022-08-10.Identifying the host genetic factors underlying severe COVID-19 is an emerging challenge. Here we conducted a genome-wide association study (GWAS) involving 2, 393 cases of COVID-19 in a cohort of Japanese individuals collected during the initial waves of the pandemic, with 3, 289 unaffected controls. We identified a variant on chromosome 5 at 5q35 (rs60200309-A), close to the dedicator of cytokinesis 2 gene (DOCK2), which was associated with severe COVID-19 in patients less than 65 years of age. This risk allele was prevalent in East Asian individuals but rare in Europeans, highlighting the value of genome-wide association studies in non-European populations. RNA-sequencing analysis of 473 bulk peripheral blood samples identified decreased expression of DOCK2 associated with the risk allele in these younger patients. DOCK2 expression was suppressed in patients with severe cases of COVID-19. Single-cell RNA-sequencing analysis (n = 61 individuals) identified cell-type-specific downregulation of DOCK2 and a COVID-19-specific decreasing effect of the risk allele on DOCK2 expression in non-classical monocytes. Immunohistochemistry of lung specimens from patients with severe COVID-19 pneumonia showed suppressed DOCK2 expression. Moreover, inhibition of DOCK2 function with CPYPP increased the severity of pneumonia in a Syrian hamster model of SARS-CoV-2 infection, characterized by weight loss, lung oedema, enhanced viral loads, impaired macrophage recruitment and dysregulated type I interferon responses. We conclude that DOCK2 has an important role in the host immune response to SARS-CoV-2 infection and the development of severe COVID-19, and could be further explored as a potential biomarker and/or therapeutic target

    鎖肛における仙椎奇形と骨盤底筋群の関係に関する臨床的実験的研究

    Get PDF

    Long term survival of a biliary atresia patient by repeated liver transplantations for portopulmonary hypertension in addition to the hepatopulmonary syndrome

    No full text
    A female patient after Kasai procedure for biliary atresia had a hepatopulmonary syndrome(HPS), and underwent living donor liver transplantation (LDLT)at 15 years old. HPS improved once, but unfortunately recurred with the graft dysfunction 10 years later, and portopulmonary hypertension (PoPH) additionally complicated at 29 years old. Following the treatment with epoprostenol, she was saved by the deceased donor liver transplantation (DDLT) at 33 years old. After the retransplant, both the HPS and PoPH quickly improved, and she has been doing well as the part time worker. Coexist of both the long-term pulmonary complications due to the liver dysfunction is quite rare, and this case documented the reversibility of the both by liver transplantation. The entire course also taught us that the patience and intimate cooperation with the patient were essential in such a long-lasting transitional care of the biliary atresia throughout the pediatric and the adolescence
    corecore