28 research outputs found

    Acute Myocarditis in Emergency Medicine

    Get PDF

    Establishment and implementation of an effective rule for the interpretation of computed tomography scans by emergency physicians in blunt trauma

    Get PDF
    INTRODUCTION: Computed tomography (CT) can detect subtle organ injury and is applicable to many body regions. However, its interpretation requires significant skill. In our hospital, emergency physicians (EPs) must interpret emergency CT scans and formulate a plan for managing most trauma cases. CT misinterpretation should be avoided, but we were initially unable to completely accomplish this. In this study, we proposed and implemented a precautionary rule for our EPs to prevent misinterpretation of CT scans in blunt trauma cases. METHODS: We established a simple precautionary rule, which advises EPs to interpret CT scans with particular care when a complicated injury is suspected per the following criteria: 1) unstable physiological condition; 2) suspicion of injuries in multiple regions of the body (e.g., brain injury plus abdominal injury); 3) high energy injury mechanism; and 4) requirement for rapid movement to other rooms for invasive treatment. If a patient meets at least one of these criteria, the EP should exercise the precautions laid out in our newly established rule when interpreting the CT scan. Additionally, our rule specifies that the EP should request real-time interpretation by a radiologist in difficult cases. We compared the accuracy of EPs’ interpretations and resulting patient outcomes in blunt trauma cases before (January 2011, June 2012) and after (July 2012, January 2013) introduction of the rule to evaluate its efficacy. RESULTS: Before the rule’s introduction, emergency CT was performed 1606 times for 365 patients. We identified 44 cases (2.7%) of minor misinterpretation and 40 (2.5%) of major misinterpretation. After introduction, CT was performed 820 times for 177 patients. We identified 10 cases (1.2%) of minor misinterpretation and two (0.2%) of major misinterpretation. Real-time support by a radiologist was requested 104 times (12.7% of all cases) and was effective in preventing misinterpretation in every case. Our rule decreased both minor and major misinterpretations in a statistically significant manner. In particular, it conspicuously decreased major misinterpretations. CONCLUSION: Our rule was easy to practice and effective in preventing EPs from missing major organ injuries. We would like to propose further large-scale multi-center trials to corroborate these results

    Investigation of the feasibility of a simple method for verifying the motion of a binary multileaf collimator synchronized with the rotation of the gantry for helical tomotherapy

    Get PDF
    In this paper, we suggest a new method for verifying the motion of a binary multileaf collimator (MLC) in helical tomotherapy. For this we used a combination of a cylindrical scintillator and a general-purpose camcorder. The camcorder records the light from the scintillator following photon irradiation, which we use to track the motion of the binary MLC. The purpose of this study is to demonstrate the feasibility of this method as a binary MLC quality assurance (QA) tool. First, the verification was performed using a simple binary MLC pattern with a constant leaf open time; secondly, verification using the binary MLC pattern used in a clinical setting was also performed. Sinograms of simple binary MLC patterns, in which leaves that were open were detected as "open" from the measured light, define the sensitivity which, in this case, was 1.000. On the other hand, the specificity, which gives the fraction of closed leaves detected as "closed", was 0.919. The leaf open error identified by our method was -1.3 +/- 7.5%. The 68.6% of observed leaves were performed within +/- 3% relative error. The leaf open error was expressed by the relative errors calculated on the sinogram. In the clinical binary MLC pattern, the sensitivity and specificity were 0.994 and 0.997, respectively. The measurement could be performed with -3.4 +/- 8.0% leaf open error. The 77.5% of observed leaves were performed within +/- 3% relative error. With this method, we can easily verify the motion of the binary MLC, and the measurement unit developed was found to be an effective QA tool.ArticleJOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS. 13(1):27-43 (2012)journal articl

    戦略的環境アセスメントのための地域景観情報の総合化

    Get PDF
    研究期間:平成14-16年度 ; 研究種目:基盤研究B1 ; 課題番号:14380274原著には既発表論文の別刷を含む
    corecore