39 research outputs found
The usefulness of chemotherapy for control of ventricular arrhythmias secondary to cardiac metastasis of germ cell tumor
SummaryA 14-year-old boy was referred to our hospital because of treatment of germ cell tumor in the anterior mediastinum. Computerized tomographic (CT) scan of the chest and abdomen revealed a large tumor in the anterior mediastinum and multiple metastatic tumors in the lung, liver, kidney, pancreas, and heart. There was a mass in the interventricular septum. A 24-h Holter monitor showed sinus rhythm with 358 premature ventricular complexes (VPC) and 30 ventricular runs including 9 non-sustained ventricular tachycardias per day. The patient was treated with 4 cycles of chemotherapy with good response. Approximately 12 weeks after the start of the chemotherapy, serial CT scan showed regression of the tumors in the anterior mediastinum, lung, and kidney, and disappearance of the tumors in the liver, pancreas, and heart. Repeat Holter monitor showed that VPC and ventricular runs disappeared completely. The chemotherapy for the germ cell tumor was very useful for ventricular arrhythmias secondary to cardiac metastasis of the tumor
First Data Release of the Hyper Suprime-Cam Subaru Strategic Program
The Hyper Suprime-Cam Subaru Strategic Program (HSC-SSP) is a three-layered
imaging survey aimed at addressing some of the most outstanding questions in
astronomy today, including the nature of dark matter and dark energy. The
survey has been awarded 300 nights of observing time at the Subaru Telescope
and it started in March 2014. This paper presents the first public data release
of HSC-SSP. This release includes data taken in the first 1.7 years of
observations (61.5 nights) and each of the Wide, Deep, and UltraDeep layers
covers about 108, 26, and 4 square degrees down to depths of i~26.4, ~26.5, and
~27.0 mag, respectively (5sigma for point sources). All the layers are observed
in five broad bands (grizy), and the Deep and UltraDeep layers are observed in
narrow bands as well. We achieve an impressive image quality of 0.6 arcsec in
the i-band in the Wide layer. We show that we achieve 1-2 per cent PSF
photometry (rms) both internally and externally (against Pan-STARRS1), and ~10
mas and 40 mas internal and external astrometric accuracy, respectively. Both
the calibrated images and catalogs are made available to the community through
dedicated user interfaces and database servers. In addition to the pipeline
products, we also provide value-added products such as photometric redshifts
and a collection of public spectroscopic redshifts. Detailed descriptions of
all the data can be found online. The data release website is
https://hsc-release.mtk.nao.ac.jp/.Comment: 34 pages, 20 figures, 7 tables, moderate revision, accepted for
publication in PAS
The Hyper Suprime-Cam SSP survey: Overview and survey design
Hyper Suprime-Cam (HSC) is a wide-field imaging camera on the prime focus of the 8.2-m Subaru telescope on the summit of Mauna Kea in Hawaii. A team of scientists from Japan, Taiwan, and Princeton University is using HSC to carry out a 300-night multi-band imaging survey of the high-latitude sky. The survey includes three layers: the Wide layer will cover 1400 deg2 in five broad bands (grizy), with a 5 σ point-source depth of r ≈ 26. The Deep layer covers a total of 26 deg2 in four fields, going roughly a magnitude fainter, while the UltraDeep layer goes almost a magnitude fainter still in two pointings of HSC (a total of 3.5 deg2). Here we describe the instrument, the science goals of the survey, and the survey strategy and data processing. This paper serves as an introduction to a special issue of the Publications of the Astronomical Society of Japan, which includes a large number of technical and scientific papers describing results from the early phases of this survey