54 research outputs found

    Association between living environmental quality and risk of arthritis in middle-aged and older adults: a national study in China

    Get PDF
    BackgroundThe association between combined environmental factors and the risk of arthritis is still scarcely studied. The present study performed cross-sectional and cohort studies to explore the association between risk score of living environment quality and the risk of arthritis in middle-aged and older adults in China.MethodsThe study was based on China Health and Retirement Longitudinal Study (CHARLS), and it recruited 17,218 participants in the cross-sectional study and 11,242 participants in the seven-year follow-up study. The living environment quality was measured by household fuel types, household water sources, room temperature, residence types, and ambient concentration of PM2.5. Logistic regression and Cox proportional hazard regression models were utilized to examine the association between the living environment quality and the risk of arthritis. Competing risk models and stratified analyses were applied to further verify our results.ResultsCompared with individuals in the suitable environment group, people who lived in moderate (OR:1.28, 95%CI: 1.14–1.43) and unfavorable environments (OR:1.49, 95%CI:1.31–1.70) showed higher risks of arthritis when considering the multiple living environmental factors (P for trend <0.001) in the cross-sectional analysis. In the follow-up study, similar results (P for trend = 0.021), moderate environment group (HR:1.26, 95%CI:1.01–1.56) and unfavorable environment group (HR: 1.36, 95%CI: 1.07–1.74), were founded.ConclusionInferior living environment might promote the development of arthritis. It is necessary for the public, especially old people, to improve the living environment, which may be the key to the primary prevention of arthritis

    FI-CEUS: a solution to improve the diagnostic accuracy in MRI LI-RADS-indeterminate (LR-3/4) FLLs at risk for HCC

    Get PDF
    ObjectiveTo evaluate the diagnostic accuracy of fusion imaging contrast-enhanced ultrasound (FI-CEUS) of magnetic resonance imaging (MRI) LI-RADS-indeterminate (LR-3/4) and conventional ultrasound undetected focal liver lesions (FLLs) in patients at risk for hepatocellular carcinoma (HCC).MethodsBetween February 2020 and July 2021, 71 FLLs in 63 patients were registered for diagnostic performance evaluation respectively for ultrasound-guided thermal ablation evaluation in this retrospective study. Diagnostic performance regarding FLLs was compared between FI-CEUS and contrast-enhanced MRI (CE-MRI).ResultsFor diagnostic performance evaluation, among 71 lesions in 63 patients, the diagnostic efficacy of FI-CEUS with LI-RADS was significantly higher than that of CE-MRI (P < 0.05) in both overall and hierarchical comparison (except for the group with lesion diameter ≥2 cm). For malignant lesions, the proportion of arterial phase hyperenhancement (APHE) and washout on FI-CEUS was higher than that on CE-MRI (P < 0.05).ConclusionFI-CEUS has a high value in the precise qualitative diagnosis of small FLLs (<2 cm) of MRI LI-RADS-indeterminate diagnosis (LR-3/4) that are undetected by conventional ultrasound in patients at risk for HCC and can be a good supplementary CE-MRI diagnostic method for thermal ablation evaluation

    Decreased soluble Nogo-B in serum as a promising biomarker for Parkinson's disease

    Get PDF
    BackgroundRecently, the neurite outgrowth inhibitor-B (Nogo-B) receptor has been reported as a novel candidate gene for Parkinson's disease (PD). Nogo-B receptors need to combine with soluble Nogo-B to exert their physiological function. However, little is known about the relationship between serum soluble Nogo-B and PD.MethodsSerum levels of sNogo-B and α-Synuclein (α-Syn) were measured in a cohort of 53 patients with PD and 49 healthy controls with the ELISA kit method.ResultsSerum sNogo-B level is significantly lower in the PD group than that in healthy controls and is negatively correlated with UPDRS-III score (p = 0.049), H&Y stage (p = 0.0108) as well as serum α-Syn level (p = 0.0001). The area under the curve (AUC) of serum sNogo-B in differentiating patients with PD from controls was 0.801 while the AUC of serum α-Syn was 0.93. Combining serum sNogo-B and α-Syn in differentiating patients with PD from HC presented higher discriminatory potential (AUC = 0.9534).ConclusionDecreased serum sNogo-B may be a potential biomarker for PD. Lower Nogo-B level reflects worse motor function and disease progression of PD. Serum sNogo-B is of added value to serum α-Syn panel in distinguishing PD from controls. Future studies are needed to confirm in larger samples and different populations

    Dominant features in three-dimensional turbulence structure: comparison of non-uniform accelerating and decelerating flows

    Get PDF
    The results are presented from an experimental study to investigate three-dimensional turbulence structure profiles, including turbulence intensity and Reynolds stress, of different non-uniform open channel flows over smooth bed in subcritical flow regime. In the analysis, the uniform flow profiles have been used to compare with those of the non-uniform flows to investigate their time-averaged spatial flow turbulence structure characteristics. The measured non-uniform velocity profiles are used to verify the von Karman constant κ and to estimate sets of log-law integration constant B r and wake parameter П, where their findings are also compared with values from previous studies. From κ, B r and П findings, it has been found that the log-wake law can sufficiently represent the non-uniform flow in its non-modified form, and all κ, B r and П follow universal rules for different bed roughness conditions. The non-uniform flow experiments also show that both the turbulence intensity and Reynolds stress are governed well by exponential pressure gradient parameter β equations. Their exponential constants are described by quadratic functions in the investigated β range. Through this experimental study, it has been observed that the decelerating flow shows higher empirical constants, in both the turbulence intensity and Reynolds stress compared to the accelerating flow. The decelerating flow also has stronger dominance to determine the flow non-uniformity, because it presents higher Reynolds stress profile than uniform flow, whereas the accelerating flow does not

    ACT001 improved cardiovascular function in septic mice by inhibiting the production of proinflammatory cytokines and the expression of JAK-STAT signaling pathway

    Get PDF
    Sepsis is a life-threatening multiple organ dysfunction syndrome (MODS) caused by a microbial infection that leads to high morbidity and mortality worldwide. Sepsis-induced cardiomyopathy (SIC) and coagulopathy promote the progression of adverse outcomes in sepsis. Here, we reported that ACT001, a modified compound of parthenolide, improved the survival of sepsis mice. In this work, we used cecal ligation and puncture (CLP) model to induce SIC. Transthoracic echocardiography and HE staining assays were adopted to evaluate the influence of ACT001 on sepsis-induced cardiac dysfunction. Our results showed that ACT001 significantly improved heart function and reduced SIC. Coagulation accelerates organ damage in sepsis. We found that ACT001 decreased blood clotting in the FeCl3-induced carotid artery thrombosis experiment. ACT001 also reduced the production of neutrophil extracellular traps (NETs). RNA-sequencing of heart tissues revealed that ACT001 significantly downregulated the expression of pro-inflammatory cytokines and the JAK-STAT signaling pathway. These results were confirmed with real-time PCR and ELISA. In summary, we found ACT001 rescued mice from septic shock by protecting the cardiovascular system. This was partially mediated by inhibiting pro-inflammatory cytokine production and down-regulating the JAK-STAT signaling

    Robust estimation of bacterial cell count from optical density

    Get PDF
    Optical density (OD) is widely used to estimate the density of cells in liquid culture, but cannot be compared between instruments without a standardized calibration protocol and is challenging to relate to actual cell count. We address this with an interlaboratory study comparing three simple, low-cost, and highly accessible OD calibration protocols across 244 laboratories, applied to eight strains of constitutive GFP-expressing E. coli. Based on our results, we recommend calibrating OD to estimated cell count using serial dilution of silica microspheres, which produces highly precise calibration (95.5% of residuals <1.2-fold), is easily assessed for quality control, also assesses instrument effective linear range, and can be combined with fluorescence calibration to obtain units of Molecules of Equivalent Fluorescein (MEFL) per cell, allowing direct comparison and data fusion with flow cytometry measurements: in our study, fluorescence per cell measurements showed only a 1.07-fold mean difference between plate reader and flow cytometry data
    corecore