47 research outputs found

    Objective measurement of nine gaze-directions using an eye-tracking device

    Get PDF
    Purpose: To investigate the usefulness and efficacy of a novel eye-tracking device that can objectively measure nine gaze-directions. Methods: We measured each of the nine gaze-directions subjectively, using a conventional Hess screen test, and objectively, using the nine gaze-direction measuring device, and de-termined the correlation, addition error, and proportional error. We obtained two consecu-tive measurements of the nine gaze-directions using the newly developed device in healthy young people with exophoria and investigated the reproducibility of the measurements. We further measured the nine gaze-directions using a Hess screen test and the newly developed device in three subjects with cover test-based strabismus and compared the results. Results: We observed that the objective measurements obtained with the newly developed gaze-direction measuring device had significant correlation and addition error compared to the conventional subjective method, and we found no proportional error. These measure-ments had good reproducibility. Conclusion: The novel device can be used to observe delayed eye movement associated with limited eye movement in the affected eye, as well as the associated excessive movement of the healthy eye in patients with strabismus, similar to the Hess screen test. This is a useful device that can provide objective measurements of nine gaze-directions

    Effects of Target Size and Test Distance on Stereoacuity

    Get PDF
    Target size and test distance effects on stereoacuity were investigated in 24 subjects using a three-dimensional monitor. Examination 1: Target Size Effects. The test distance was 2.5 m for 0.1°, 0.2°, 0.5°, and 0.9° target sizes; crossed parallax was presented in 22-second units. Average stereoacuity values for 0.1°, 0.2°, 0.5°, and 0.9° target sizes were 59.58±14.86, 47.66±13.71, 41.25±15.95, and 39.41±15.52 seconds, respectively. Stereoacuity was significantly worse with a 0.1° target than with 0.2°, 0.5°, and 0.9° target sizes (P=0.03, P<0.0001, and P<0.0001, resp.). Examination 2: Test Distance Effects. Test distances of 2.5, 5.0, and 7.5 m were investigated for a 0.5° target size; crossed parallax was presented in 22-second units. Average stereoacuity values at 2.5 m, 5.0 m, and 7.5 m test distances were 44.91±16.16, 34.83±10.84, and 24.75±7.27 seconds, respectively. Stereoacuity at a 7.5 m distance was significantly better than at distances of 2.5 m and 5.0 m (P<0.0001 and P=0.02, resp.). Stereoacuity at a 5.0 m distance was significantly better than at 2.5 m (P=0.04). Stereoacuity should be estimated by both parallax and other elements, including test distance and target size

    Unraveling infectious structures, strain variants and species barriers for the yeast prion [PSI+]

    Get PDF
    Prions are proteins that can access multiple conformations, at least one of which is beta-sheet rich, infectious and self-perpetuating in nature. These infectious proteins show several remarkable biological activities, including the ability to form multiple infectious prion conformations, also known as strains or variants, encoding unique biological phenotypes, and to establish and overcome prion species (transmission) barriers. In this Perspective, we highlight recent studies of the yeast prion [PSI+], using various biochemical and structural methods, that have begun to illuminate the molecular mechanisms by which self-perpetuating prions encipher such biological activities. We also discuss several aspects of prion conformational change and structure that remain either unknown or controversial, and we propose approaches to accelerate the understanding of these enigmatic, infectious conformers

    Global Patterns and Controls of Nutrient Immobilization On Decomposing Cellulose In Riverine Ecosystems

    Get PDF
    Microbes play a critical role in plant litter decomposition and influence the fate of carbon in rivers and riparian zones. When decomposing low-nutrient plant litter, microbes acquire nitrogen (N) and phosphorus (P) from the environment (i.e., nutrient immobilization), and this process is potentially sensitive to nutrient loading and changing climate. Nonetheless, environmental controls on immobilization are poorly understood because rates are also influenced by plant litter chemistry, which is coupled to the same environmental factors. Here we used a standardized, low-nutrient organic matter substrate (cotton strips) to quantify nutrient immobilization at 100 paired stream and riparian sites representing 11 biomes worldwide. Immobilization rates varied by three orders of magnitude, were greater in rivers than riparian zones, and were strongly correlated to decomposition rates. In rivers, P immobilization rates were controlled by surface water phosphate concentrations, but N immobilization rates were not related to inorganic N. The N:P of immobilized nutrients was tightly constrained to a molar ratio of 10:1 despite wide variation in surface water N:P. Immobilization rates were temperature-dependent in riparian zones but not related to temperature in rivers. However, in rivers nutrient supply ultimately controlled whether microbes could achieve the maximum expected decomposition rate at a given temperature

    The disruption of proteostasis in neurodegenerative diseases

    Get PDF
    Cells count on surveillance systems to monitor and protect the cellular proteome which, besides being highly heterogeneous, is constantly being challenged by intrinsic and environmental factors. In this context, the proteostasis network (PN) is essential to achieve a stable and functional proteome. Disruption of the PN is associated with aging and can lead to and/or potentiate the occurrence of many neurodegenerative diseases (ND). This not only emphasizes the importance of the PN in health span and aging but also how its modulation can be a potential target for intervention and treatment of human diseases.info:eu-repo/semantics/publishedVersio

    Physiological and genetic basis for variation in migratory behavior in the three-spined stickleback, Gasterosteus aculeatus

    Full text link

    Comparison of Amblyopia Treatment Effect with Dichoptic Method Using Polarizing Film and Occlusion Therapy Using an Eye Patch

    No full text
    We developed a novel, low-cost, easily administered method that uses a polarizing film to enable dichoptic treatment for amblyopia. In this study, we compared its effects with occlusion therapy using an eye patch. Fifty-eight patients (aged 4.7 ± 1.0 years) diagnosed with anisometric amblyopia were included and instructed to wear complete refractive correction glasses with either occlusion therapy using an eye patch (eye patch group) or dichoptic treatment using polarizing film (polarizing film group) for 2 h per day. We examined the improvement in the visual acuity and compliance rate of the patients 2 months after treatment initiation. After treatment, the polarizing film group showed significant improvement in visual acuity compared with the eye patch group. Moreover, the compliance rate was significantly better in the polarizing film group than in the eye patch group. In both groups, there was a significant correlation between the improvement in visual acuity and compliance rate. This new dichoptic treatment using a polarizing film was shown to be effective for anisometropic amblyopia

    Comparison between Amblyopia Treatment with Glasses Only and Combination of Glasses and Open-Type Binocular “Occlu-Pad” Device

    No full text
    We evaluated amblyopia treatment, comparing training with glasses only and training with glasses and the Occlu-pad, a binocular open-type amblyopia training device. Forty-six children (4.8±1.1 years) diagnosed with anisometropic amblyopia, all wearing complete correction glasses, were treated either with glasses only, or with glasses in combination with the Occlu-pad (training time: 2 days a week, 30 minutes per day). We compared visual acuity scores at 3 and 6 months after treatment had started, and examined the compliance rate for the Occlu-pad training. Three months as well as 6 months after amblyopia treatment started, the “Occlu-pad treatment group” showed significantly improved visual acuity, compared to the “Glasses treatment group” (at both 3 and 6 months: p<0.0001). The compliance rate for using the Occlu-pad was 88.4±18.7% after 3 months and 69.6±19.5%, after 6 months. There was no significant correlation between the training time using the Occlu-pad and improvement in visual acuity (3 months: p=0.97; 6 months: p=0.55). The compliance rate for months 4 to 6 was significantly lower than that for months 1 to 3 (p=0.003). Amblyopia treatment using the Occlu-pad device in combination with glasses led to a better effect than treatment with glasses alone

    Short-term Results of Arthroscopic Debridement for Hemodialysis Knee

    No full text
    corecore