79 research outputs found

    Seismic performance of group pile foundation with ground improvement during liquefaction

    Get PDF
    A pile foundation with ground improvement under the footing is a composite foundation with the objectives of enhancing the seismic performance and rationalizing the substructure by combining the pile foundation with ground improvement. Although the effectiveness of this method has been confirmed in previous studies for application to soft grounds, the applicability of this method to liquefiable grounds has yet to be fully investigated. In this study, therefore, centrifuge model tests and finite element analyses were conducted to clarify the effectiveness of this method and to ascertain the improvement in strength (stiffness) when the method is applied to a liquefiable ground. Firstly, in order to investigate the effect of an improved ground on the behavior of the pile foundation during liquefaction, dynamic centrifuge model tests were conducted for three cases with different strengths of the improved ground. Then, three-dimensional soil–water coupled finite element analyses of the centrifuge model experiments were performed to validate the applicability of the analytical method. After that, parametric studies, in which the strength of the improved ground and the input ground motion were changed, were conducted using the same analytical model. The results confirmed that the horizontal displacement of the pile heads was reduced by the improved ground even in the liquefiable ground, and that the effect of this reduction was more remarkable in cases of high stiffness of the improved ground. Furthermore, it was possible to reduce the bending moments at the pile heads by applying the ground improvement. However, since the bending moment at the boundary between the improved ground and the natural ground became the local maximum, there was an optimum stiffness of the ground improvement at which the maximum bending moment of the piles was reduced. This is because improving the ground around the pile heads has the same effect as extending the footing. It was thus concluded that the behavior of the pile foundation is similar to that of a composite foundation comprised of a caisson and group piles

    Direct Determination of the Blood Concentration of Halogenated Anesthetic Agents by Gas Chromatography

    Get PDF
    The direct determination by gas chromatography of blood levels of anesthetic agents has been difficult because of the water content of blood. In the present study, the method of Yokota et al. (1967) was modified by improving the packing materials of the column, the blood sample vaporizer and the flow-path during analysis. As a result, accurate and reproducible determination of halothane, enflurane and isoflurane dissolved in blood was achieved. With this system, blood in which halothane, enflurane and isoflurane had been dissolved could be analyzed without changing the column between samples. Moreover, each sample was prepared in less than 10 min, and more than 100 consecutive determinations could be made with excellent reproducibility. The coefficient of variation was less than 3.8%.</p

    Usefulness of the forced oscillation technique in assessing the therapeutic result of tracheobronchial central airway obstruction

    Get PDF
    Background: Pulmonary function tests (PFTs) comprise the traditional method for detecting central airway obstruction (CAO) and evaluating therapeutic effects, but are effort dependent. By contrast, the forced oscillation technique (FOT) is performed during tidal breathing in an effort-independent mode and is universally used to assess respiratory function in patients with chronic obstructive pulmonary disease (COPD) and asthma. We used the FOT to measure airway resistance and reactance in patients with CAO before and after interventional bronchoscopy and compared the results to data obtained using PFTs. Methods: Twelve patients with CAO were recruited from December 2013 to July 2016. The FOT, PFTs, chest computed tomography (CT), COPD Assessment Test (CAT), and the modified Medical Research Council (mMRC) dyspnea scale were employed before and after interventional bronchoscopy. The minimum airway cross-sectional area (MACSA) was calculated using a CT image calculator. Results: Of the 12 patients, 6 had tracheal obstruction and 6 had bronchial obstruction. All FOT measurements, except Delta XS, were significantly improved after interventional bronchoscopy in all cases. The significance of the improvement was greater with the FOT than PFTs. The MACSA, CAT, and mMRC dyspnea scale scores also significantly improved in all cases. Furthermore, only alteration of resistance at 20 Hz (R20) significantly correlated with the alteration of the MACSA after intervention. No significant correlations were found for PFTs. Conclusions: The FOT is suitable and convenient for assessing therapeutic results in patients with tracheobronchial CAO. The alteration of R20 is useful for estimating the airway dilation of CAO after interventional bronchoscopy. (C)2018 The Japanese Respiratory Society. Published by Elsevier B.V. All rights reserved.ArticleRESPIRATORY INVESTIGATION.56(3):222-229(2018)journal articl

    The ASTRO-H X-ray Observatory

    Full text link
    The joint JAXA/NASA ASTRO-H mission is the sixth in a series of highly successful X-ray missions initiated by the Institute of Space and Astronautical Science (ISAS). ASTRO-H will investigate the physics of the high-energy universe via a suite of four instruments, covering a very wide energy range, from 0.3 keV to 600 keV. These instruments include a high-resolution, high-throughput spectrometer sensitive over 0.3-2 keV with high spectral resolution of Delta E < 7 eV, enabled by a micro-calorimeter array located in the focal plane of thin-foil X-ray optics; hard X-ray imaging spectrometers covering 5-80 keV, located in the focal plane of multilayer-coated, focusing hard X-ray mirrors; a wide-field imaging spectrometer sensitive over 0.4-12 keV, with an X-ray CCD camera in the focal plane of a soft X-ray telescope; and a non-focusing Compton-camera type soft gamma-ray detector, sensitive in the 40-600 keV band. The simultaneous broad bandpass, coupled with high spectral resolution, will enable the pursuit of a wide variety of important science themes.Comment: 22 pages, 17 figures, Proceedings of the SPIE Astronomical Instrumentation "Space Telescopes and Instrumentation 2012: Ultraviolet to Gamma Ray

    SORL1 Is Genetically Associated with Late-Onset Alzheimer’s Disease in Japanese, Koreans and Caucasians

    Get PDF
    To discover susceptibility genes of late-onset Alzheimer’s disease (LOAD), we conducted a 3-stage genome-wide association study (GWAS) using three populations: Japanese from the Japanese Genetic Consortium for Alzheimer Disease (JGSCAD), Koreans, and Caucasians from the Alzheimer Disease Genetic Consortium (ADGC). In Stage 1, we evaluated data for 5,877,918 genotyped and imputed SNPs in Japanese cases (n = 1,008) and controls (n = 1,016). Genome-wide significance was observed with 12 SNPs in the APOE region. Seven SNPs from other distinct regions with p-values ,261025 were genotyped in a second Japanese sample (885 cases, 985 controls), and evidence of association was confirmed for one SORL1 SNP (rs3781834, P=7.3361027 in the combined sample). Subsequent analysis combining results for several SORL1 SNPs in the Japanese, Korean (339 cases, 1,129 controls) and Caucasians (11,840 AD cases, 10,931 controls) revealed genome wide significance with rs11218343 (P=1.7761029) and rs3781834 (P=1.0461028). SNPs in previously established AD loci in Caucasians showed strong evidence of association in Japanese including rs3851179 near PICALM (P=1.7161025) and rs744373 near BIN1 (P = 1.3961024). The associated allele for each of these SNPs was the same as in Caucasians. These data demonstrate for the first time genome-wide significance of LOAD with SORL1 and confirm the role of other known loci for LOAD in Japanese. Our study highlights the importance of examining associations in multiple ethnic populations

    Apolipoprotein E4 Frequencies in a Japanese Population with Alzheimer's Disease and Dementia with Lewy Bodies

    Get PDF
    BACKGROUND: The apolipoprotein E (APOE) ε4 allele has been reported to be a risk factor for Alzheimer's disease (AD) and dementia with Lewy bodies (DLB). Previous neuropathological studies have demonstrated similar frequencies of the APOE ε4 allele in AD and DLB. However, the few ante-mortem studies on APOE allele frequencies in DLB have shown lower frequencies than post-mortem studies. One reason for this may be inaccuracy of diagnosis. We examined APOE genotypes in subjects with AD, DLB, and a control group using the latest diagnostic criteria and MRI, SPECT, and MIBG myocardial scintigraphy. METHODS: The subjects of this study consisted of 145 patients with probable AD, 50 subjects with probable DLB, and a control group. AD subjects were divided into two groups based on age of onset: early onset AD (EOAD) and late onset AD (LOAD). All subjects had characteristic features on MRI, SPECT, and/or myocardial scintigraphy. RESULTS: The rate of APOE4 carrier status was 18.3% and the frequency of the ε4 allele was 9.7% in controls. The rate of APOE4 carrier status and the frequency of the ε4 allele were 47% and 27% for LOAD, 50% and 31% for EOAD, and 42% and 31% for DLB, respectively. CONCLUSION: The APOE4 genotypes in this study are consistent with previous neuropathological studies suggesting accurate diagnosis of AD and DLB. APOE4 genotypes were similar in AD and DLB, giving further evidence that the ε4 allele is a risk factor for both disorders
    corecore