1,883 research outputs found

    Highly sensitive transient absorption imaging of graphene and graphene oxide in living cells and circulating blood

    Get PDF
    We report a transient absorption (TA) imaging method for fast visualization and quantitative layer analysis of graphene and GO. Forward and backward imaging of graphene on various substrates under ambient condition was imaged with a speed of 2 μs per pixel. The TA intensity linearly increased with the layer number of graphene. Real-time TA imaging of GO in vitro with capability of quantitative analysis of intracellular concentration and ex vivo in circulating blood were demonstrated. These results suggest that TA microscopy is a valid tool for the study of graphene based materials

    Subacute Neurological Deterioration with Selective Axonal Injury in Patients with Acute Ischemic Stroke following Reperfusion of Middle Cerebral Artery Occlusion

    Get PDF
    To date, the long-term effects of reperfusion on the salvaged brain tissues have not been addressed in the literature. We report 4 cases presenting subacute neurological deteriorations with selective axonal injury following reperfusion therapies for acute ischemic stroke. Our case series based on 4 patients showed common features distinct from those of early reperfusion injury in that (1) the neurological symptoms developed after 1-2 months of reperfusion therapies, (2) these symptoms were accompanied by the subcortical white matter changes on brain MRI, and (3) these findings were mostly reversible with time. This suggests that axons in the reperfused brain may be vulnerable to further neurological injury

    Patterns of Using Complementary and Alternative Medicine by Stroke Patients at Two University Hospitals in Korea

    Get PDF
    This study measured the prevalence of complementary and alternative medicine (CAM) use among Korean stroke patients. Questionnaire-based 20-min interviews were conducted at the hospitals by a trained nurse after an outpatient visit. It included questions on demographic information, clinical information and the utilization of CAM. Of 304 stroke-patient respondents, 164 (54%) had used CAM, of which 66% had started taking CAM products following suggestions from family members and other relatives. Of the 57% of users who felt that CAM was effective, 84% considered that it improved the symptoms of stroke and 16% felt it was effective in achieving psychological relaxation. Of the eight CAM categories used by respondents, 92% used traditional Oriental medical treatments, 36% used plant- and animal-derived over-the-counter health care products, 24% used minerals and vitamins, and 11% used manual therapies. The majority of stroke patients (68%) were trying a new type of CAM, and half of the respondents (45%) relied on the knowledge of their general practitioner about CAMs when deciding whether to use them. Most of the stroke patients in this study used CAM, and a half of them reported beneficial effects. Despite the presence of adverse side effects, they tended to be used without discussion with chief physicians, and hence physicians should be actively involved in the usage of CAM

    Use of graphene as protection film in biological environments

    Get PDF
    Corrosion of metal in biomedical devices could cause serious health problems to patients. Currently ceramics coating materials used in metal implants can reduce corrosion to some extent with limitations. Here we proposed graphene as a biocompatible protective film for metal potentially for biomedical application. We confirmed graphene effectively inhibits Cu surface from corrosion in different biological aqueous environments. Results from cell viability tests suggested that graphene greatly eliminates the toxicity of Cu by inhibiting corrosion and reducing the concentration of Cu(2+) ions produced. We demonstrated that additional thiol derivatives assembled on graphene coated Cu surface can prominently enhance durability of sole graphene protection limited by the defects in graphene film. We also demonstrated that graphene coating reduced the immune response to metal in a clinical setting for the first time through the lymphocyte transformation test. Finally, an animal experiment showed the effective protection of graphene to Cu under in vivo condition. Our results open up the potential for using graphene coating to protect metal surface in biomedical application

    Non-Invasive Follow-up Evaluation of Post-Embolized AVM with Time-Resolved MRA: A Case Report

    Get PDF
    We report the hemodynamic assessment in a patient with cerebral arteriovenous malformation using time-resolved magnetic resonance angiography (TR-MRA), a non-invasive modality, and catheter-based digital subtraction angiography (DSA), before and after embolization. Comparison of the results showed that TR-MRA produced very fast dynamic images and the findings closely matched those obtained at DSA. For initial work-up and follow-up studies in patients with vascular lesions, TR-MRA and DSA are therefore comparable

    Central Neurocytoma: A Review of Clinical Management and Histopathologic Features.

    Get PDF
    Central neurocytoma (CN) is a rare, benign brain tumor often located in the lateral ventricles. CN may cause obstructive hydrocephalus and manifest as signs of increased intracranial pressure. The goal of treatment for CN is a gross total resection (GTR), which often yields excellent prognosis with a very high rate of tumor control and survival. Adjuvant radiosurgery and radiotherapy may be considered to improve tumor control when GTR cannot be achieved. Chemotherapy is also not considered a primary treatment, but has been used as a salvage therapy. The radiological features of CN are indistinguishable from those of other brain tumors; therefore, many histological markers, such as synaptophysin, can be very useful for diagnosing CNs. Furthermore, the MIB-1 Labeling Index seems to be correlated with the prognosis of CN. We also discuss oncogenes associated with these elusive tumors. Further studies may improve our ability to accurately diagnose CNs and to design the optimal treatment regimens for patients with CNs

    A Study of Micronucleus Induction with Methyl Formate and 2-Methylbutane in Bone Marrow Cells of Male ICR Mice

    Get PDF
    Objectives: We investigated the genotoxicity of two chemicals, methyl formate and 2-methylbutane, using male ICR mice bone marrow cells for the screening of micronucleus induction. Although these two chemicals have already been tested numerous times, a micronucleus test has not been conducted and the amounts used have recently been increased.Methods: 7 week male ICR mice were tested at dosages of 250, 500, and 1,000mg/kg for methyl formate and 500, 1,000, and 2,000mg/kg for 2-methlybutane, respectively. After 24 hours of oral administration with the two chemicals, the mice were sacrificed and their bone marrow cells were prepared for smearing slides.Results: As a result of counting the micronucleated polychromatic erythrocyte (MNPCE) of 2,000 polychromatic erythrocytes (PCE), all treated groups expressed no statistically significant increase of MNPCE compared to the negative control group. There were no clinical signs related with the oral exposure of these two chemicals.Conclusion: It was concluded that the two chemicals did not induce micronucleus in the bone marrow cells of ICR mice, and there was no direct proportion with dosage. These results indicate that the two chemicals have no mutagenic potential under each study condition

    Catalytic Performance for Hydrocarbon Production from Syngas on the Promoted Co-Based Hybrid Catalysts; Influence of Pt Contents

    Get PDF
    Fischer-Tropsch synthesis (FTS) reaction from syngas was investigated on the Pt-promoted cobalt-based hybrid catalysts prepared by co-precipitation method in a slurry of ZSM-5 (Si/Al=25). The hybrid catalysts were compared with each other for the different content of Pt as a promoter and are characterized using BET, XRD, H2-TPR and NH3-TPD. Their physicochemical properties were correlated with the activity and selectivity of the catalysts. As results, all hybrid catalysts show the C5-C9 yield (%) higher than that of Co-Al2O3/ZSM-5 catalyst. The Pt-promoted hybrid catalysts were found to be more promising towards production of the hydrocarbons of gasoline range and over C10.

    Effect of intradialytic change in blood pressure and ultrafiltration volume on the variation in access flow measured by ultrasound dilution

    Get PDF
    AbstractBackgroundProspective access flow measurement is the preferred method for vascular access surveillance in hemodialysis (HD) patients. We studied the effect of intradialytic change in blood pressure and ultrafiltration volume on the variation in access flow measured by ultrasound dilution.MethodsAccess flow was measured 30minutes, 120minutes, and 240minutes after the start of HD by ultrasound dilution in 30 patients during 89 HD sessions and evaluated for variation.ResultsThe mean age of the 30 patients was 62±11 years: 19 were male. The accesses comprised 16 fistulae and 14 grafts. The mean access flow over all sessions decreased by 6.1% over time (1265±568mL/min after 30minutes, 1260±599mL/min after 120minutes, and 1197±576mL/min after 240minutes, P<0.01 by repeated measures ANOVA). In addition, a≥5% decrease in mean arterial pressure during HD significantly reduced access flow (P=0.014). However, no other variable (ultrafiltration volume, sex, age, presence of diabetes, type or location of access, body surface area, hemoglobin, serum albumin level) interacted significantly with the effect of time on access flow. Furthermore, mean arterial pressure did not correlate with ultrafiltration volume.ConclusionWe conclude that the variation in access flow during HD is relatively small. Decreased blood pressure is a risk factor for variation in access flow measured by ultrasound dilution. In most patients whose blood pressures are stable during HD, the access flow can be measured at any time during the HD treatment
    corecore