1,074 research outputs found

    Epidural Hematoma Following Cervical Spine Surgery.

    Get PDF
    STUDY DESIGN: A multicentered retrospective case series. OBJECTIVE: To determine the incidence and circumstances surrounding the development of a symptomatic postoperative epidural hematoma in the cervical spine. METHODS: Patients who underwent cervical spine surgery between January 1, 2005, and December 31, 2011, at 23 institutions were reviewed, and all patients who developed an epidural hematoma were identified. RESULTS: A total of 16 582 cervical spine surgeries were identified, and 15 patients developed a postoperative epidural hematoma, for a total incidence of 0.090%. Substantial variation between institutions was noted, with 11 sites reporting no epidural hematomas, and 1 site reporting an incidence of 0.76%. All patients initially presented with a neurologic deficit. Nine patients had complete resolution of the neurologic deficit after hematoma evacuation; however 2 of the 3 patients (66%) who had a delay in the diagnosis of the epidural hematoma had residual neurologic deficits compared to only 4 of the 12 patients (33%) who had no delay in the diagnosis or treatment (P = .53). Additionally, the patients who experienced a postoperative epidural hematoma did not experience any significant improvement in health-related quality-of-life metrics as a result of the index procedure at final follow-up evaluation. CONCLUSION: This is the largest series to date to analyze the incidence of an epidural hematoma following cervical spine surgery, and this study suggest that an epidural hematoma occurs in approximately 1 out of 1000 cervical spine surgeries. Prompt diagnosis and treatment may improve the chance of making a complete neurologic recovery, but patients who develop this complication do not show improvements in the health-related quality-of-life measurements

    C5 Palsy After Cervical Spine Surgery: A Multicenter Retrospective Review of 59 Cases.

    Get PDF
    STUDY DESIGN: A multicenter, retrospective review of C5 palsy after cervical spine surgery. OBJECTIVE: Postoperative C5 palsy is a known complication of cervical decompressive spinal surgery. The goal of this study was to review the incidence, patient characteristics, and outcome of C5 palsy in patients undergoing cervical spine surgery. METHODS: We conducted a multicenter, retrospective review of 13 946 patients across 21 centers who received cervical spine surgery (levels C2 to C7) between January 1, 2005, and December 31, 2011, inclusive. P values were calculated using 2-sample t test for continuous variables and χ(2) tests or Fisher exact tests for categorical variables. RESULTS: Of the 13 946 cases reviewed, 59 patients experienced a postoperative C5 palsy. The incidence rate across the 21 sites ranged from 0% to 2.5%. At most recent follow-up, 32 patients reported complete resolution of symptoms (54.2%), 15 had symptoms resolve with residual effects (25.4%), 10 patients did not recover (17.0%), and 2 were lost to follow-up (3.4%). CONCLUSION: C5 palsy occurred in all surgical approaches and across a variety of diagnoses. The majority of patients had full recovery or recovery with residual effects. This study represents the largest series of North American patients reviewed to date

    Long‑Term Safety and Efectiveness of PF‑05280014 (a Trastuzumab Biosimilar) Treatment in Patients with HER2‑Positive Metastatic Breast cancer: Updated Results of a Randomized, Double‑Blind Study

    Get PDF
    Background PF-05280014 was compared with trastuzumab sourced from the European Union (trastuzumab-EU), each plus paclitaxel, as frst-line treatment for human epidermal growth factor receptor 2-positive metastatic breast cancer in a phase III study. Equivalence between treatment groups was demonstrated. Objective The aim of this study was to report long-term safety and overall survival (OS) over 6 years after the frst patient was screened. Patients and methods Randomized patients received intravenous PF-05280014 or trastuzumab-EU, each plus paclitaxel, until objective disease progression. OS, long-term safety, subgroup safety (patients ongoing after day 378), and time-totreatment discontinuation (TTD) were assessed based on the fnal statistical analysis plan amended for the ad-hoc analyses. Results Of 707 randomized patients (n = 352, PF-05280014; n = 355, trastuzumab-EU), 252 (71.6%) in the PF-05280014 and 251 (70.7%) in the trastuzumab-EU group discontinued treatment due to objective progression. Overall, 451 (63.8%) patients completed the study. Between groups (PF-05280014; trastuzumab-EU), estimated median TTDs were 12.25 and 12.06 months (p = 0.692); 61 (17.3%) and 67 (18.9%) patients died; stratifed hazard ratio for OS was 0.929 (95% confdence interval 0.656–1.316; p = 0.339); estimated survival rates were 82.3 and 77.4% at 2 years and 77.2 and 75.3% at 3 years. The incidences of treatment-emergent adverse events (TEAEs) overall (98.6%; 96.6%) and for grades ≥3 (41.0%; 43.1%) were comparable between groups. In patients (n = 265; n = 264) ongoing after day 378, the incidences of any TEAEs, grade ≥3 TEAEs, and serious TEAEs were comparable between the treatment groups. Conclusion Long-term safety and OS were consistent with previous results and demonstrated no clinically meaningful differences between treatment groups. Trial registration ClinicalTrials.gov: NCT01989676 (21 November 2013); and EudraCT: 2013-001352-34 (18 December 2013)

    UCI EyeMobile Exam Findings from School Children Following on-Site Screening

    Get PDF
    John D Hong,1 Elliot H Choi,1 Susie Suh,1 Joseph H Bui,1 Annabelle M Storch,1 Kimberly R Walker,1 Kourosh Shahraki,1 Carolina Yanez,1 Diana Torres,1 Jennifer Espinoza,1 Iliana Molina,2,* Donny W Suh1,* 1Gavin Herbert Eye Institute, Department of Ophthalmology, University of California, Irvine, CA, USA; 2Shiley Eye Institute, Department of Ophthalmology, University of California, San Diego, CA, USA*These authors contributed equally to this workCorrespondence: Donny W Suh, Gavin Herbert Eye Institute, Department of Ophthalmology, University of California, Irvine, 850 Health Sciences Road, Irvine, CA, 92697, USA, Tel +1 949 824-4122, Email [email protected] Iliana Molina, Shiley Eye Institute, Department of Ophthalmology, University of California, San Diego, 9415 Campus Point Dr, San Diego, CA, 92037, USA, Tel +1 858 822-2585, Email [email protected]: Uncorrected refractive errors (REs) and amblyopia can lead to visual impairment with deleterious effects on quality of life and academic performance. Early detection and treatment by community vision care programs, such as the UCI EyeMobile for Children, can aid in addressing preventable vision loss.Methods: A total of 5074 children between the ages of 3 and 10 years were screened at 153 locations, including preschools, head start programs, and elementary schools within Orange County (OC), California (CA). Subsequently, 1024 children presented for comprehensive eye examinations. A retrospective analysis of all examined children was conducted, determining the frequency and severity of REs and amblyopia and the spectacle prescription rate by age. Propensity score matching analysis evaluated the effect of median household income on RE and amblyopia frequency.Results: Among those who failed initial screening and were subsequently examined, significant rates of REs and amblyopia were detected: myopia (24.4%), hyperopia (35.4%), astigmatism (71.8%), anisometropia (8.9%), amblyopia (7.0%), and amblyopia risk (14.4%). A majority (65.0%) of those examined received prescription spectacles from UCI EyeMobile, with around a third requiring a new or updated prescription. The frequency of REs and amblyopia and the spectacle prescription rate were uniform across OC congressional districts. Myopia and amblyopia risk was positively and negatively associated with household income, respectively.Conclusion: The UCI EyeMobile for Children serves as a vital vision care program, providing free vision screening, comprehensive eye examinations, and spectacles. A significant number of children required examination, and a high frequency of REs and amblyopia were detected in examined children, with subsequent provision of prescription spectacles to most children.Keywords: pediatrics, refractive error, amblyopia, spectacles, mobile clinic, screenin

    Search for transient optical counterparts to high-energy IceCube neutrinos with Pan-STARRS1

    Get PDF
    In order to identify the sources of the observed diffuse high-energy neutrino flux, it is crucial to discover their electromagnetic counterparts. IceCube began releasing alerts for single high-energy (E>60E > 60 TeV) neutrino detections with sky localisation regions of order 1 deg radius in 2016. We used Pan-STARRS1 to follow-up five of these alerts during 2016-2017 to search for any optical transients that may be related to the neutrinos. Typically 10-20 faint (m<22.5m < 22.5 mag) extragalactic transients are found within the Pan-STARRS1 footprints and are generally consistent with being unrelated field supernovae (SNe) and AGN. We looked for unusual properties of the detected transients, such as temporal coincidence of explosion epoch with the IceCube timestamp. We found only one transient that had properties worthy of a specific follow-up. In the Pan-STARRS1 imaging for IceCube-160427A (probability to be of astrophysical origin of \sim50 %), we found a SN PS16cgx, located at 10.0' from the nominal IceCube direction. Spectroscopic observations of PS16cgx showed that it was an H-poor SN at z = 0.2895. The spectra and light curve resemble some high-energy Type Ic SNe, raising the possibility of a jet driven SN with an explosion epoch temporally coincident with the neutrino detection. However, distinguishing Type Ia and Type Ic SNe at this redshift is notoriously difficult. Based on all available data we conclude that the transient is more likely to be a Type Ia with relatively weak SiII absorption and a fairly normal rest-frame r-band light curve. If, as predicted, there is no high-energy neutrino emission from Type Ia SNe, then PS16cgx must be a random coincidence, and unrelated to the IceCube-160427A. We find no other plausible optical transient for any of the five IceCube events observed down to a 5σ\sigma limiting magnitude of m22m \sim 22 mag, between 1 day and 25 days after detection.Comment: 20 pages, 6 figures, accepted to A&

    Differential limit on the extremely-high-energy cosmic neutrino flux in the presence of astrophysical background from nine years of IceCube data

    Get PDF
    We report a quasi-differential upper limit on the extremely-high-energy (EHE) neutrino flux above 5×1065\times 10^{6} GeV based on an analysis of nine years of IceCube data. The astrophysical neutrino flux measured by IceCube extends to PeV energies, and it is a background flux when searching for an independent signal flux at higher energies, such as the cosmogenic neutrino signal. We have developed a new method to place robust limits on the EHE neutrino flux in the presence of an astrophysical background, whose spectrum has yet to be understood with high precision at PeV energies. A distinct event with a deposited energy above 10610^{6} GeV was found in the new two-year sample, in addition to the one event previously found in the seven-year EHE neutrino search. These two events represent a neutrino flux that is incompatible with predictions for a cosmogenic neutrino flux and are considered to be an astrophysical background in the current study. The obtained limit is the most stringent to date in the energy range between 5×1065 \times 10^{6} and 5×10105 \times 10^{10} GeV. This result constrains neutrino models predicting a three-flavor neutrino flux of $E_\nu^2\phi_{\nu_e+\nu_\mu+\nu_\tau}\simeq2\times 10^{-8}\ {\rm GeV}/{\rm cm}^2\ \sec\ {\rm sr}at at 10^9\ {\rm GeV}$. A significant part of the parameter-space for EHE neutrino production scenarios assuming a proton-dominated composition of ultra-high-energy cosmic rays is excluded.Comment: The version accepted for publication in Physical Review

    Neutrinos below 100 TeV from the southern sky employing refined veto techniques to IceCube data

    Get PDF
    Many Galactic sources of gamma rays, such as supernova remnants, are expected to produce neutrinos with a typical energy cutoff well below 100 TeV. For the IceCube Neutrino Observatory located at the South Pole, the southern sky, containing the inner part of the Galactic plane and the Galactic Center, is a particularly challenging region at these energies, because of the large background of atmospheric muons. In this paper, we present recent advancements in data selection strategies for track-like muon neutrino events with energies below 100 TeV from the southern sky. The strategies utilize the outer detector regions as veto and features of the signal pattern to reduce the background of atmospheric muons to a level which, for the first time, allows IceCube searching for point-like sources of neutrinos in the southern sky at energies between 100 GeV and several TeV in the muon neutrino charged current channel. No significant clustering of neutrinos above background expectation was observed in four years of data recorded with the completed IceCube detector. Upper limits on the neutrino flux for a number of spectral hypotheses are reported for a list of astrophysical objects in the southern hemisphere.Comment: 19 pages, 17 figures, 2 table
    corecore