1,132 research outputs found
Possibility of Measuring Azimuthal Anisotropy in Absorption in the ALICE Experiment
The absorption of J/ψ by comovers in the forward rapidity region is predicted to be azimuthally anisotropic as compared to an isotropic Glauber absorption. In the framework of a fast simulation we investigate the possibility of measuring this anisotropy within the ALICE experiment for the J/ψ 's detected in the Di-Muon Spectrometer using the event plane provided by the Photon Multiplicity Detector(PMD). The effect of limitations in the event plane determination on measured J/ψ anisotropy is also investigated
Measurement of electrical properties of electrode materials for the bakelite Resistive Plate Chambers
Single gap (gas gap 2 mm) bakelite Resistive Plate Chamber (RPC) modules of
various sizes from 10 cm \times 10 cm to 1 m \times 1 m have been fabricated,
characterized and optimized for efficiency and time resolution. Thin layers of
different grades of silicone compound are applied to the inner electrode
surfaces to make them smooth and also to reduce the surface resistivity. In the
silicone coated RPCs an efficiency > 90% and time resolution \sim 2 ns (FWHM)
have been obtained for both the streamer and the avalanche mode of operation.
Before fabrication of detectors the electrical properties such as bulk
resistivity and surface resistivity of the electrode materials are measured
carefully. Effectiveness of different silicone coating in modifying the surface
resistivity was evaluated by an instrument developed for monitoring the I-V
curve of a high resistive surface. The results indicate definite correlation of
the detector efficiency for the atmospheric muons and the RPC noise rates with
the surface resistivity and its variation with the applied bias voltage. It was
also found that the surface resistivity varies for different grades of silicone
material applied as coating, and the results are found to be consistent with
the detector efficiency and noise rate measurements done with these RPCs.Comment: 9 Pages, 6 figure
Measurement of electrical properties of electrode materials for the bakelite Resistive Plate Chambers
Single gap (gas gap 2 mm) bakelite Resistive Plate Chamber (RPC) modules of
various sizes from 10 cm \times 10 cm to 1 m \times 1 m have been fabricated,
characterized and optimized for efficiency and time resolution. Thin layers of
different grades of silicone compound are applied to the inner electrode
surfaces to make them smooth and also to reduce the surface resistivity. In the
silicone coated RPCs an efficiency > 90% and time resolution \sim 2 ns (FWHM)
have been obtained for both the streamer and the avalanche mode of operation.
Before fabrication of detectors the electrical properties such as bulk
resistivity and surface resistivity of the electrode materials are measured
carefully. Effectiveness of different silicone coating in modifying the surface
resistivity was evaluated by an instrument developed for monitoring the I-V
curve of a high resistive surface. The results indicate definite correlation of
the detector efficiency for the atmospheric muons and the RPC noise rates with
the surface resistivity and its variation with the applied bias voltage. It was
also found that the surface resistivity varies for different grades of silicone
material applied as coating, and the results are found to be consistent with
the detector efficiency and noise rate measurements done with these RPCs.Comment: 9 Pages, 6 figure
Sequential Decay Distortion of Goldhaber Model Widths for Spectator Fragments
Momentum widths of the primary fragments and observed final fragments have
been investigated within the framework of an Antisymmetrized Molecular Dynamics
transport model code (AMD-V) with a sequential decay afterburner (GEMINI). It
is found that the secondary evaporation effects cause the values of a reduced
momentum width, , derived from momentum widths of the final fragments
to be significantly less than those appropriate to the primary fragment but
close to those observed in many experiments. Therefore, a new interpretation
for experiemental momentum widths of projectile-like fragments is presented.Comment: 4 pages, 3 figs. Accepted for publication in Phys. Rev. C as a Rapid
Communicatio
Sequential Decay Distortion of Goldhaber Model Widths for Spectator Fragments
Momentum widths of the primary fragments and observed final fragments have
been investigated within the framework of an Antisymmetrized Molecular Dynamics
transport model code (AMD-V) with a sequential decay afterburner (GEMINI). It
is found that the secondary evaporation effects cause the values of a reduced
momentum width, , derived from momentum widths of the final fragments
to be significantly less than those appropriate to the primary fragment but
close to those observed in many experiments. Therefore, a new interpretation
for experiemental momentum widths of projectile-like fragments is presented.Comment: 4 pages, 3 figs. Accepted for publication in Phys. Rev. C as a Rapid
Communicatio
Isolation of Flow and Nonflow Correlations by Two- and Four-Particle Cumulant Measurements of Azimuthal Harmonics in 200 GeV Au+Au Collisions
A data-driven method was applied to measurements of Au+Au collisions at
200 GeV made with the STAR detector at RHIC to isolate
pseudorapidity distance -dependent and -independent
correlations by using two- and four-particle azimuthal cumulant measurements.
We identified a component of the correlation that is -independent,
which is likely dominated by anisotropic flow and flow fluctuations. It was
also found to be independent of within the measured range of
pseudorapidity . The relative flow fluctuation was found to be for particles of transverse momentum
less than GeV/. The -dependent part may be attributed to
nonflow correlations, and is found to be relative to the
flow of the measured second harmonic cumulant at
- …