485 research outputs found

    Fast-ion-induced secondary ion emission from submicron droplet surfaces studied using a new coincidence technique with forward-scattered projectiles

    Get PDF
    A mass spectrometric study of secondary ions emitted from droplet surfaces by MeV-energy heavy ion impact was performed to investigate fast-ion-induced molecular reaction processes on liquid surfaces. Herein, a new coincidence technique was developed between secondary ions and scattered projectile ions at a small forward angle. The advantages of this technique were demonstrated by measurement of the collision between 4-MeV C3+ and ethanol droplets. Secondary ion emission probabilities were obtained directly from the coincidence data. Notably, this technique enabled positive fragment ions that had not been identified in previous measurements to be observed by suppressing the strong background originating from gas-phase molecules more than 104-fold. H+, H3O+, C2H5+, and C2H5O+ were found to be produced as major positive fragment ions, in addition to minor fragments H2+, C2H3+, and CH2OH+. Production of these ions suggests that competition between rapid hydrogen ion emission from multiply ionized states and intermolecular proton transfer accompanied by fragmentation through protonated ethanol occurs after fast heavy-ion collisions. Clarification of the positive fragment ions also revealed the characteristic features of negative ions. Negative ions were realized to exhibit higher degrees of fragmentation and reactivity compared with positive ions. Furthermore, the energy loss by forward-scattered ions during droplet penetration was used to evaluate the target thickness at a submicron level. Variations in secondary ion yield, mass distribution, and kinetic energies depending on the penetration length were observed below 1 µm. These results highlight the unknown mechanism of these “submicron effects” observed in secondary ion emission processes as a new phenomenon

    Positive and negative ion emission from microdroplets by MeV energy ions

    Get PDF
    XXIX International Conference on Photonic, Electronic, and Atomic Collisions (ICPEAC2015): 22–28 July 2015, Toledo, SpainWe have developed a new experimental setup that allowed us to study collision interactions between fast ion beams and liquid droplets under a vacuum condition. Droplets of water and ethanol are irradiated with 0.4-1.5 MeV H+ and 2.0 MeV C2+ ions. The droplet diameter is estimated from energy loss measurements of projectile ions penetrating through droplets. Time-of-flight mass spectra of positive and negative secondary ions exhibit a series of cluster ions generated via protonation and deprotonation

    A Three-Dimensional Quantum Simulation of Silicon Nanowire Transistors with the Effective-Mass Approximation

    Get PDF
    The silicon nanowire transistor (SNWT) is a promising device structure for future integrated circuits, and simulations will be important for understanding its device physics and assessing its ultimate performance limits. In this work, we present a three-dimensional quantum mechanical simulation approach to treat various SNWTs within the effective-mass approximation. We begin by assuming ballistic transport, which gives the upper performance limit of the devices. The use of a mode space approach (either coupled or uncoupled) produces high computational efficiency that makes our 3D quantum simulator practical for extensive device simulation and design. Scattering in SNWTs is then treated by a simple model that uses so-called Buttiker probes, which was previously used in metal-oxide-semiconductor field effect transistor (MOSFET) simulations. Using this simple approach, the effects of scattering on both internal device characteristics and terminal currents can be examined, which enables our simulator to be used for the exploration of realistic performance limits of SNWTs.Comment: 38 pages, 11 figures, submitted to Journal of Applied Physic

    PDGFRα plays a crucial role in connective tissue remodeling.

    Get PDF
    Platelet derived growth factor (PDGF) plays a pivotal role in the remodeling of connective tissues. Emerging data indicate the distinctive role of PDGF receptor-α (PDGFRα) in this process. In the present study, the Pdgfra gene was systemically inactivated in adult mouse (α-KO mouse), and the role of PDGFRα was examined in the subcutaneously implanted sponge matrices. PDGFRα expressed in the fibroblasts of Pdgfra-preserving control mice (Flox mice), was significantly reduced in the sponges in α-KO mice. Neovascularized areas were largely suppressed in the α-KO mice than in the Flox mice, whereas the other parameters related to the blood vessels and endothelial cells were similar. The deposition of collagen and fibronectin and the expression of collagen 1a1 and 3a1 genes were significantly reduced in α-KO mice. There was a significantly decrease in the number and dividing fibroblasts in the α-KO mice, and those of macrophages were similar between the two genotypes. Hepatocyte growth factor (Hgf) gene expression was suppressed in Pdgfra-inactivated fibroblasts and connective tissue. The findings implicate the role of PDGFRα-dependent ECM and HGF production in fibroblasts that promotes the remodeling of connective tissue and suggest that PDGFRα may be a relevant target to regulate connective tissue remodeling

    Radio-frequency capacitance spectroscopy of metallic nanoparticles

    Get PDF
    Recent years have seen great progress in our understanding of the electronic properties of nanomaterials in which at least one dimension measures less than 100 nm. However, contacting true nanometer scale materials such as individual molecules or nanoparticles remains a challenge as even state-of-the-art nanofabrication techniques such as electron-beam lithography have a resolution of a few nm at best. Here we present a fabrication and measurement technique that allows high sensitivity and high bandwidth readout of discrete quantum states of metallic nanoparticles which does not require nm resolution or precision. This is achieved by coupling the nanoparticles to resonant electrical circuits and measurement of the phase of a reflected radio-frequency signal. This requires only a single tunnel contact to the nanoparticles thus simplifying device fabrication and improving yield and reliability. The technique is demonstrated by measurements on 2.7 nm thiol coated gold nanoparticles which are shown to be in excellent quantitative agreement with theory

    Effect of cross exercise on quadriceps acceleration reaction time and subjective scores (Lysholm questionnaire) following anterior cruciate ligament reconstruction

    Get PDF
    Abstract Background Anterior cruciate ligament (ACL) injury or reconstruction can cause knee impairments and disability. Knee impairments are related to quadriceps performance – accelerated reaction time (ART) – and disability to performance of daily living activities which is assessed by questionnaires such as the Lysholm knee score. The purposes of this study were to investigate the effect of cross exercise, as supplementary rehabilitation to the early phase of ACL reconstruction: a) on quadriceps ART at the angles 45°, 60° and 90° of knee flexion and, b) on the subjective scores of disability in ACL reconstructed patients. Methods 42 patients who underwent ACL reconstruction were randomly divided into 3 groups, two experimental and one control. All groups followed the same rehabilitation program. The experimental groups followed 8 weeks of cross eccentric exercise (CEE) on the uninjured knee; 3 d/w, and 5 d/w respectively. Quadriceps ART was measured at 45°, 60° and 90° of knee flexion pre and nine weeks post-operatively using an isokinetic dynamometer. Patients also completed pre and post operatively the Lysholm questionnaire whereby subjective scores were recorded. Results Two factor ANOVA showed significant differences in ART at 90° among the groups (F = 4.29, p = 0.02, p Significant differences were also found in the Lysholm score among the groups (F = 4.75, p = 0.01, p Conclusion CEE showed improvements on quadriceps ART at 90° at a sequence of 3 d/w and in the Lysholm score at a sequence of 3 d/w and 5 d/w respectively on ACL reconstructed patients.</p
    corecore