82 research outputs found

    Testing a Family Supportive End of Life Care Intervention in a Chinese Neonatal Intensive Care Unit: A Quasi-experimental Study With a Non-randomized Controlled Trial Design

    Get PDF
    Background: Neonatal death often occurs in tertiary Neonatal Intensive Care Units (NICUs). In China, end-of-life-care (EOLC) does not always involve parents. Aim: The aim of this study is to evaluate a parent support intervention to integrate parents at the end of life of their infant in the NICU. Methods: A quasi-experimental study using a non-randomized clinical trial design was conducted between May 2020 and September 2021. Participants were infants in an EOLC pathway in the NICU and their parents. Parents were allocated into a family supportive EOLC intervention group or a standard EOLC group based on their wishes. The primary outcomes depression (Edinburgh Postnatal Depression Scale for mothers; Hamilton Depression rating scale for fathers) and Satisfaction with Care were measured 1 week after infants' death. Student t-test for continuous variables and the Chi-square test categorical variables were used in the statistical analysis. Results: In the study period, 62 infants died and 45 infants and 90 parents were enrolled; intervention group 20 infants, standard EOLC group 25 infants. The most common causes of death in both groups were congenital abnormalities (n = 20, 44%). Mean gestational age of infants between the family supportive EOLC group and standard EOLC group was 31.45 vs. 33.8 weeks (p = 0.234). Parents between both groups did not differ in terms of age, delivery of infant, and economic status. In the family support group, higher education levels were observed among mother (p = 0.026) and fathers (p = 0.020). Both mothers and fathers in the family supportive EOLC group had less depression compared to the standard EOLC groups; mothers (mean 6.90 vs. 7.56; p = 0.017) and fathers (mean 20.7 vs. 23.1; p < 0.001). Parents reported higher satisfaction in the family supportive EOLC group (mean 88.9 vs. 86.6; p < 0.001). Conclusions: Supporting parents in EOLC in Chinese NICUs might decreased their depression and increase satisfaction after the death of their infant. Future research needs to focus on long-term effects and expand on larger populations with different cultural backgrounds. Clinical Trial Registration: www.ClinicalTrials.gov, identifier: NCT05270915

    Quantum Dimensional Zeeman Effect in the Magneto-optical Absorption Spectrum for Quantum Dot - Impurity Center Systems

    Get PDF
    Magneto-optical properties of the quantum dot - impurity center (QD-IC) systems synthesized in a transparent dielectric matrix are considered. For the QD one-electron state description the parabolic model of the confinement potential is used. Within the framework of zero-range potential model and the effective mass approach, the light impurity absorption coefficient for the case of transversal polarization with respect to the applied magnetic field direction, with consideration of the QD size dispersion, has been analytically calculated. It is shown that for the case of transversal polarization the light impurity absorption spectrum is characterized by the quantum dimensional Zeeman effect.Comment: 18 pages, 1 figure, PDF fil

    Quantifying atmospheric nitrogen deposition through a nationwide monitoring network across China

    Get PDF
    A Nationwide Nitrogen Deposition Monitoring Network (NNDMN) containing 43 monitoring sites was established in China to measure gaseous NH3, NO2, and HNO3 and particulate NH4+ and NO3− in air and/or precipitation from 2010 to 2014. Wet/bulk deposition fluxes of Nr species were collected by precipitation gauge method and measured by continuous-flow analyzer; dry deposition fluxes were estimated using airborne concentration measurements and inferential models. Our observations reveal large spatial variations of atmospheric Nr concentrations and dry and wet/bulk Nr deposition. On a national basis, the annual average concentrations (1.3–47.0 ÎŒg N m−3) and dry plus wet/bulk deposition fluxes (2.9–83.3 kg N ha−1 yr−1) of inorganic Nr species are ranked by land use as urban > rural > background sites and by regions as north China > southeast China > southwest China > northeast China > northwest China > Tibetan Plateau, reflecting the impact of anthropogenic Nr emission. Average dry and wet/bulk N deposition fluxes were 20.6 ± 11.2 (mean ± standard deviation) and 19.3 ± 9.2 kg N ha−1 yr−1 across China, with reduced N deposition dominating both dry and wet/bulk deposition. Our results suggest atmospheric dry N deposition is equally important to wet/bulk N deposition at the national scale. Therefore, both deposition forms should be included when considering the impacts of N deposition on environment and ecosystem health

    Integrating sequence and array data to create an improved 1000 Genomes Project haplotype reference panel

    Get PDF
    A major use of the 1000 Genomes Project (1000GP) data is genotype imputation in genome-wide association studies (GWAS). Here we develop a method to estimate haplotypes from low-coverage sequencing data that can take advantage of single-nucleotide polymorphism (SNP) microarray genotypes on the same samples. First the SNP array data are phased to build a backbone (or 'scaffold') of haplotypes across each chromosome. We then phase the sequence data 'onto' this haplotype scaffold. This approach can take advantage of relatedness between sequenced and non-sequenced samples to improve accuracy. We use this method to create a new 1000GP haplotype reference set for use by the human genetic community. Using a set of validation genotypes at SNP and bi-allelic indels we show that these haplotypes have lower genotype discordance and improved imputation performance into downstream GWAS samples, especially at low-frequency variants. © 2014 Macmillan Publishers Limited. All rights reserved

    International nosocomial infection control consortium (INICC) report, data summary of 36 countries, for 2004-2009

    Get PDF
    The results of a surveillance study conducted by the International Nosocomial Infection Control Consortium (INICC) from January 2004 through December 2009 in 422 intensive care units (ICUs) of 36 countries in Latin America, Asia, Africa, and Europe are reported. During the 6-year study period, using Centers for Disease Control and Prevention (CDC) National Healthcare Safety Network (NHSN; formerly the National Nosocomial Infection Surveillance system [NNIS]) definitions for device-associated health care-associated infections, we gathered prospective data from 313,008 patients hospitalized in the consortium's ICUs for an aggregate of 2,194,897 ICU bed-days. Despite the fact that the use of devices in the developing countries' ICUs was remarkably similar to that reported in US ICUs in the CDC's NHSN, rates of device-associated nosocomial infection were significantly higher in the ICUs of the INICC hospitals; the pooled rate of central line-associated bloodstream infection in the INICC ICUs of 6.8 per 1,000 central line-days was more than 3-fold higher than the 2.0 per 1,000 central line-days reported in comparable US ICUs. The overall rate of ventilator-associated pneumonia also was far higher (15.8 vs 3.3 per 1,000 ventilator-days), as was the rate of catheter-associated urinary tract infection (6.3 vs. 3.3 per 1,000 catheter-days). Notably, the frequencies of resistance of Pseudomonas aeruginosa isolates to imipenem (47.2% vs 23.0%), Klebsiella pneumoniae isolates to ceftazidime (76.3% vs 27.1%), Escherichia coli isolates to ceftazidime (66.7% vs 8.1%), Staphylococcus aureus isolates to methicillin (84.4% vs 56.8%), were also higher in the consortium's ICUs, and the crude unadjusted excess mortalities of device-related infections ranged from 7.3% (for catheter-associated urinary tract infection) to 15.2% (for ventilator-associated pneumonia). Copyright © 2012 by the Association for Professionals in Infection Control and Epidemiology, Inc. Published by Elsevier Inc. All rights reserved
    • 

    corecore