43 research outputs found

    How Do Physical Therapists Treat People with Knee Osteoarthritis, and What Drives Their Clinical Decisions? A Population-Based Cross-Sectional Survey.

    Get PDF
    Purpose: It is unclear how physical therapists in Florida currently treat people with knee osteoarthritis and whether current best evidence is used in clinical decision making. Methods: We conducted a survey of physical therapists in Florida. We assessed the perceived effectiveness and actual use of physical therapy (PT) interventions and quantified the association between the actual use of interventions and different characteristics of physical therapists. Results: A total of 413 physical therapists completed the survey. Most respondents perceived therapeutic exercise (94%) and education (93%) as being effective or very effective. Interventions least perceived as effective or very effective were electrotherapy (28%), wedged insole (20%), and ultrasound (19%). Physical therapists who followed the principles of evidence-based practice were more likely to use therapeutic exercise (OR 3.89; 95% CI: 1.21, 12.54) and education (OR 3.63; 95% CI: 1.40, 9.43) and less likely to use ultrasound (OR 0.32; 95% CI: 0.16, 0.63) and electrotherapy (OR 0.32; 95% CI: 0.17, 0.58). Results also indicated that older physical therapists were more likely to use ultrasound (OR 3.57; 95% CI: 1.60, 7.96), electrotherapy (OR 2.53; 95% CI: 1.17, 5.47), kinesiology tape (OR 3.82; 95% CI: 1.59, 9.18), and ice (OR 1.95; 95% CI: 1.02, 3.73). Conclusions: In line with clinical guidelines, most physical therapists use therapeutic exercise and education to treat people with knee osteoarthritis. However, interventions that lack scientific support, such as electrotherapy and ultrasound, are still used. A modifiable therapist characteristic, adherence to evidence-based practice, is positively associated with the use of interventions supported by scientific evidence

    Diagnostic accuracy of magnetic resonance enterography and small bowel ultrasound for the extent and activity of newly diagnosed and relapsed Crohn's disease (METRIC): a multicentre trial

    Get PDF
    Magnetic resonance enterography (MRE) and ultrasound are used to image Crohn's disease, but their comparative accuracy for assessing disease extent and activity is not known with certainty. Therefore, we did a multicentre trial to address this issue. We recruited patients from eight UK hospitals. Eligible patients were 16 years or older, with newly diagnosed Crohn's disease or with established disease and suspected relapse. Consecutive patients had MRE and ultrasound in addition to standard investigations. Discrepancy between MRE and ultrasound for the presence of small bowel disease triggered an additional investigation, if not already available. The primary outcome was difference in per-patient sensitivity for small bowel disease extent (correct identification and segmental localisation) against a construct reference standard (panel diagnosis). This trial is registered with the International Standard Randomised Controlled Trial, number ISRCTN03982913, and has been completed. 284 patients completed the trial (133 in the newly diagnosed group, 151 in the relapse group). Based on the reference standard, 233 (82%) patients had small bowel Crohn's disease. The sensitivity of MRE for small bowel disease extent (80% [95% CI 72-86]) and presence (97% [91-99]) were significantly greater than that of ultrasound (70% [62-78] for disease extent, 92% [84-96] for disease presence); a 10% (95% CI 1-18; p=0·027) difference for extent, and 5% (1-9; p=0·025) difference for presence. The specificity of MRE for small bowel disease extent (95% [85-98]) was significantly greater than that of ultrasound (81% [64-91]); a difference of 14% (1-27; p=0·039). The specificity for small bowel disease presence was 96% (95% CI 86-99) with MRE and 84% (65-94) with ultrasound (difference 12% [0-25]; p=0·054). There were no serious adverse events. Both MRE and ultrasound have high sensitivity for detecting small bowel disease presence and both are valid first-line investigations, and viable alternatives to ileocolonoscopy. However, in a national health service setting, MRE is generally the preferred radiological investigation when available because its sensitivity and specificity exceed ultrasound significantly. National Institute of Health and Research Health Technology Assessment. [Abstract copyright: Copyright © 2018 The Author(s). Published by Elsevier Ltd. This is an Open Access article under the CC BY 4.0 license. Published by Elsevier Ltd.. All rights reserved.

    Diagnostic accuracy for the extent and activity of newly diagnosed and relapsed Crohn’s disease: a multicentre prospective comparison of magnetic resonance enterography and small bowel ultrasound –The METRIC Trial

    Get PDF
    Background Magnetic resonance enterography (MRE) and ultrasound (US) are used to image Crohn’s disease, but comparative accuracy for disease extent and activity is not known with certainty. We undertook a prospective multicentre cohort trial to address this Methods We recruited from 8 UK hospitals. Eligible patients were 16 years or older, newly diagnosed with Crohn’s disease, or had established disease with suspected relapse. Consecutive patients underwent MRE and US in addition to standard investigations. Discrepancy between MRE and US for small bowel (SB) disease presence triggered an additional investigation, if not already available. The primary outcome was difference in per patient sensitivity for SB disease extent (correct identification and segmental localisation) against a construct reference standard (panel diagnosis). Accuracy for SB and colonic disease presence and activity were secondary outcomes. The trial is completed (ISRCTN03982913). Findings 284 patients completed the trial (133 new diagnosis, 151 relapse). MRE sensitivity (n=233) for SB disease extent (80% [95%CI 72 to 86]) and presence (97% [91 to 99]) were significantly greater than US (70% [62 to 78], 92% [84 to 96]); a 10% (1 to 18; p=0.027), and 5% (1 to 9), difference respectively. MRE specificity for SB disease extent (95% [85 to 98]) was significantly greater than US (81% [64 to 91]). Sensitivity for active SB disease was significantly greater for MRE than US (96% [92 to 99] vs. 90% [82 to 95]), difference 6% (2 to 11). Overall, there were no significant accuracy differences for colonic disease presence. Accuracy in newly diagnosed and relapse patients was similar, although US had significantly greater sensitivity for colonic disease than MRE in newly diagnosed patients (67% [49 to 81) vs. 47% [31 to 64]), difference 20% (1 to 39). There were no serious adverse events. Interpretation MRE has higher diagnostic accuracy for the extent and activity of SB Crohn’s disease than US when tested in a prospective multi centre cohort trial setting

    Magnetic resonance enterography compared with ultrasonography in newly diagnosed and relapsing Crohn's disease patients: the METRIC diagnostic accuracy study

    Get PDF
    Magnetic resonance enterography and enteric ultrasonography are used to image Crohn's disease patients. Their diagnostic accuracy for presence, extent and activity of enteric Crohn's disease was compared. To compare diagnostic accuracy, observer variability, acceptability, diagnostic impact and cost-effectiveness of magnetic resonance enterography and ultrasonography in newly diagnosed or relapsing Crohn's disease. Prospective multicentre cohort study. Eight NHS hospitals. Consecutive participants aged ≥ 16 years, newly diagnosed with Crohn's disease or with established Crohn's disease and suspected relapse. Magnetic resonance enterography and ultrasonography. The primary outcome was per-participant sensitivity difference between magnetic resonance enterography and ultrasonography for small bowel Crohn's disease extent. Secondary outcomes included sensitivity and specificity for small bowel Crohn's disease and colonic Crohn's disease extent, and sensitivity and specificity for small bowel Crohn's disease and colonic Crohn's disease presence; identification of active disease; interobserver variation; participant acceptability; diagnostic impact; and cost-effectiveness. Out of the 518 participants assessed, 335 entered the trial, with 51 excluded, giving a final cohort of 284 (133 and 151 in new diagnosis and suspected relapse cohorts, respectively). Across the whole cohort, for small bowel Crohn's disease extent, magnetic resonance enterography sensitivity [80%, 95% confidence interval (CI) 72% to 86%] was significantly greater than ultrasonography sensitivity (70%, 95% CI 62% to 78%), with a 10% difference (95% CI 1% to 18%;  = 0.027). For small bowel Crohn's disease extent, magnetic resonance enterography specificity (95%, 95% CI 85% to 98%) was significantly greater than ultrasonography specificity (81%, 95% CI 64% to 91%), with a 14% difference (95% CI 1% to 27%). For small bowel Crohn's disease presence, magnetic resonance enterography sensitivity (97%, 95% CI 91% to 99%) was significantly greater than ultrasonography sensitivity (92%, 95% CI 84% to 96%), with a 5% difference (95% CI 1% to 9%). For small bowel Crohn's disease presence, magnetic resonance enterography specificity was 96% (95% CI 86% to 99%) and ultrasonography specificity was 84% (95% CI 65% to 94%), with a 12% difference (95% CI 0% to 25%). Test sensitivities for small bowel Crohn's disease presence and extent were similar in the two cohorts. For colonic Crohn's disease presence in newly diagnosed participants, ultrasonography sensitivity (67%, 95% CI 49% to 81%) was significantly greater than magnetic resonance enterography sensitivity (47%, 95% CI 31% to 64%), with a 20% difference (95% CI 1% to 39%). For active small bowel Crohn's disease, magnetic resonance enterography sensitivity (96%, 95% CI 92% to 99%) was significantly greater than ultrasonography sensitivity (90%, 95% CI 82% to 95%), with a 6% difference (95% CI 2% to 11%). There was some disagreement between readers for both tests. A total of 88% of participants rated magnetic resonance enterography as very or fairly acceptable, which is significantly lower than the percentage (99%) of participants who did so for ultrasonography. Therapeutic decisions based on magnetic resonance enterography alone and ultrasonography alone agreed with the final decision in 122 out of 158 (77%) cases and 124 out of 158 (78%) cases, respectively. There were no differences in costs or quality-adjusted life-years between tests. Magnetic resonance enterography and ultrasonography scans were interpreted by practitioners blinded to clinical data (but not participant cohort), which does not reflect use in clinical practice. Magnetic resonance enterography has higher accuracy for detecting the presence, extent and activity of small bowel Crohn's disease than ultrasonography does. Both tests have variable interobserver agreement and are broadly acceptable to participants, although ultrasonography produces less participant burden. Diagnostic impact and cost-effectiveness are similar. Recommendations for future work include investigation of the comparative utility of magnetic resonance enterography and ultrasonography for treatment response assessment and investigation of non-specific abdominal symptoms to confirm or refute Crohn's disease. Current Controlled Trials ISRCTN03982913. This project was funded by the National Institute for Health Research (NIHR) Health Technology Assessment programme and will be published in full in ; Vol. 23, No. 42. See the NIHR Journals Library website for further project information

    Genome modeling system: A knowledge management platform for genomics

    Get PDF
    In this work, we present the Genome Modeling System (GMS), an analysis information management system capable of executing automated genome analysis pipelines at a massive scale. The GMS framework provides detailed tracking of samples and data coupled with reliable and repeatable analysis pipelines. The GMS also serves as a platform for bioinformatics development, allowing a large team to collaborate on data analysis, or an individual researcher to leverage the work of others effectively within its data management system. Rather than separating ad-hoc analysis from rigorous, reproducible pipelines, the GMS promotes systematic integration between the two. As a demonstration of the GMS, we performed an integrated analysis of whole genome, exome and transcriptome sequencing data from a breast cancer cell line (HCC1395) and matched lymphoblastoid line (HCC1395BL). These data are available for users to test the software, complete tutorials and develop novel GMS pipeline configurations. The GMS is available at https://github.com/genome/gms

    Multiple novel prostate cancer susceptibility signals identified by fine-mapping of known risk loci among Europeans

    Get PDF
    Genome-wide association studies (GWAS) have identified numerous common prostate cancer (PrCa) susceptibility loci. We have fine-mapped 64 GWAS regions known at the conclusion of the iCOGS study using large-scale genotyping and imputation in 25 723 PrCa cases and 26 274 controls of European ancestry. We detected evidence for multiple independent signals at 16 regions, 12 of which contained additional newly identified significant associations. A single signal comprising a spectrum of correlated variation was observed at 39 regions; 35 of which are now described by a novel more significantly associated lead SNP, while the originally reported variant remained as the lead SNP only in 4 regions. We also confirmed two association signals in Europeans that had been previously reported only in East-Asian GWAS. Based on statistical evidence and linkage disequilibrium (LD) structure, we have curated and narrowed down the list of the most likely candidate causal variants for each region. Functional annotation using data from ENCODE filtered for PrCa cell lines and eQTL analysis demonstrated significant enrichment for overlap with bio-features within this set. By incorporating the novel risk variants identified here alongside the refined data for existing association signals, we estimate that these loci now explain ∼38.9% of the familial relative risk of PrCa, an 8.9% improvement over the previously reported GWAS tag SNPs. This suggests that a significant fraction of the heritability of PrCa may have been hidden during the discovery phase of GWAS, in particular due to the presence of multiple independent signals within the same regio

    Finishing the euchromatic sequence of the human genome

    Get PDF
    The sequence of the human genome encodes the genetic instructions for human physiology, as well as rich information about human evolution. In 2001, the International Human Genome Sequencing Consortium reported a draft sequence of the euchromatic portion of the human genome. Since then, the international collaboration has worked to convert this draft into a genome sequence with high accuracy and nearly complete coverage. Here, we report the result of this finishing process. The current genome sequence (Build 35) contains 2.85 billion nucleotides interrupted by only 341 gaps. It covers ∼99% of the euchromatic genome and is accurate to an error rate of ∼1 event per 100,000 bases. Many of the remaining euchromatic gaps are associated with segmental duplications and will require focused work with new methods. The near-complete sequence, the first for a vertebrate, greatly improves the precision of biological analyses of the human genome including studies of gene number, birth and death. Notably, the human enome seems to encode only 20,000-25,000 protein-coding genes. The genome sequence reported here should serve as a firm foundation for biomedical research in the decades ahead

    Beside the Seaside. The archaeology of the twentieth-century English seaside holiday experience: a phenomenological context.

    Get PDF
    A recent survey commissioned by English Heritage highlights the rich cultural history of the traditional English seaside resort (Brodie and Winter 2007). Emerging in the eighteenth century, these towns grew in significance before the advent of cheaper continental holidays in the 1960s signalled their demise. Nevertheless they retain an affectionate place within English social memory, and are in their own right distinctive maritime communities. Using an archaeological case study and a broadly phenomenological approach this contribution analyses the experience of the resort holiday through reference to place, space and materiality. Further, it seeks to situate the English seaside resort, as a functionally distinctive post-medieval urban and maritime phenomenon, within a global context of the archaeology of tourism

    Multiplatform Analysis of 12 Cancer Types Reveals Molecular Classification within and across Tissues of Origin

    Get PDF
    Recent genomic analyses of pathologically-defined tumor types identify “within-a-tissue” disease subtypes. However, the extent to which genomic signatures are shared across tissues is still unclear. We performed an integrative analysis using five genome-wide platforms and one proteomic platform on 3,527 specimens from 12 cancer types, revealing a unified classification into 11 major subtypes. Five subtypes were nearly identical to their tissue-of-origin counterparts, but several distinct cancer types were found to converge into common subtypes. Lung squamous, head & neck, and a subset of bladder cancers coalesced into one subtype typified by TP53 alterations, TP63 amplifications, and high expression of immune and proliferation pathway genes. Of note, bladder cancers split into three pan-cancer subtypes. The multi-platform classification, while correlated with tissue-of-origin, provides independent information for predicting clinical outcomes. All datasets are available for data-mining from a unified resource to support further biological discoveries and insights into novel therapeutic strategies
    corecore