6 research outputs found

    Study of hydrodynamic behaviour in a conical fluidized bed dryer using pressure fluctuation analysis and X-ray densitometry

    Get PDF
    Fluidized bed dryers (FBDs) are used in the pharmaceutical industry to remove excess moisture from granule prior to tablet formation. As granule moisture content is reduced from its initial to final state, the velocity required to fully fluidize the granule decreases and the bed voidage decreases. The change in these fluidization properties are attributed to the decrease in the interparticle force load created by a reduction in liquid bridging as moisture is removed. During constant velocity drying, these fluidization properties result in a bubbling fluidization state, which evolves into a bubble coalescing regime as drying proceeds. This behaviour was identifiable using pressure fluctuation time-series analysis techniques. Distributor design studies using dry and wet granule in a conical fluidized bed suggest that the punched plate design limits bubble coalescence when compared to the perforated plate and Dutch weave mesh designs. Furthermore, the Dutch weave results in extensive segregation, which is undesirable from a fluidization perspective. Local drying hydrodynamic measurements using x-ray densitometry found that the punched and perforated plates generate a centralized bubbling core region during drying with a defluidized bed periphery. This fluidized core region grows as drying proceeds until the defluidized region disappears. Under the same operating conditions, a porous plate distributor creates extensive channelling and defluidization across the entire bed cross-section during the constant rate period of drying. These poor fluidization characteristics are a result of the porous plate introducing the gas into the bed as a fine dispersion. Lastly, the hydrodynamics associated with the conical vessel geometry improves the circulation and mixing patterns in fluidized bed dryers. This is especially the case in the entry region of the conical bed where the high inlet gas velocity prevents defluidization around the periphery of the bed. The straight walled geometry of the cylindrical bed resulted in defluidization in this area. As a result, the hydrodynamics associated with bubbling differ significantly between the geometries over the course of drying

    The Influence of Distributor Design on Fluidized Bed Dryer Hydrodynamics

    Get PDF
    The influence of perforated plate, punched plate and Dutch weave mesh distributor designs on fluidized bed dryer hydrodynamics was studied for a range of bed loadings and superficial gas velocities. The punched plate performs better than the other designs at a gas velocity of 1.5 m/s and bed loadings greater than 1.0 kg

    Reliability of routinely collected anthropometric measurements in primary care

    No full text
    Background Measuring body mass index (BMI) has been proposed as a method of screening for preventive primary care and population surveillance of childhood obesity. However, the accuracy of routinely collected measurements has been questioned. The purpose of this study was to assess the reliability of height, length and weight measurements collected during well-child visits in primary care relative to trained research personnel. Methods A cross-sectional study of measurement reliability was conducted in community pediatric and family medicine primary care practices. Each participating child, ages 0 to 18 years, was measured four consecutive times; twice by a primary care team member (e.g. nurses, practice personnel) and twice by a trained research assistant. Inter- and intra-observer reliability was calculated using the technical error of measurement (TEM), relative TEM (%TEM), and a coefficient of reliability (R). Results Six trained research assistants and 16 primary care team members performed measurements in three practices. All %TEM values for intra-observer reliability of length, height, and weight were classified as ‘acceptable’ ( 99% for both intra- and inter-observer reliability. Length measurements in children Conclusion There was agreement between routine measurements and research measurements although there were some differences in length measurement reliability between practice staff and research assistants. These results provide justification for using routinely collected data from selected primary care practices for secondary purposes such as BMI population surveillance and research.</p

    Prospective cohort study of vitamin D and autism spectrum disorder diagnoses in early childhood

    No full text
    corecore