The Influence of Distributor Design on Fluidized Bed Dryer Hydrodynamics

Abstract

The influence of perforated plate, punched plate and Dutch weave mesh distributor designs on fluidized bed dryer hydrodynamics was studied for a range of bed loadings and superficial gas velocities. The punched plate performs better than the other designs at a gas velocity of 1.5 m/s and bed loadings greater than 1.0 kg