750 research outputs found

    Status of the LUX Dark Matter Search

    Full text link
    The Large Underground Xenon (LUX) dark matter search experiment is currently being deployed at the Homestake Laboratory in South Dakota. We will highlight the main elements of design which make the experiment a very strong competitor in the field of direct detection, as well as an easily scalable concept. We will also present its potential reach for supersymmetric dark matter detection, within various timeframes ranging from 1 year to 5 years or more.Comment: 4 pages, in proceedings of the SUSY09 conferenc

    The ZEPLIN-III dark matter detector: instrument design, manufacture and commissioning

    Get PDF
    We present details of the technical design and manufacture of the ZEPLIN-III dark matter experiment. ZEPLIN-III is a two-phase xenon detector which measures both the scintillation light and the ionisation charge generated in the liquid by interacting particles and radiation. The instrument design is driven by both the physics requirements and by the technology requirements surrounding the use of liquid xenon. These include considerations of key performance parameters, such as the efficiency of scintillation light collection, restrictions placed on the use of materials to control the inherent radioactivity levels, attainment of high vacuum levels and chemical contamination control. The successful solution has involved a number of novel design and manufacturing features which will be of specific use to future generations of direct dark matter search experiments as they struggle with similar and progressively more demanding requirements.Comment: 25 pages, 19 figures. Submitted to Astropart. Phys. Some figures down sampled to reduce siz

    Inverting Time-Dependent Harmonic Oscillator Potential by a Unitary Transformation and a New Class of Exactly Solvable Oscillators

    Get PDF
    A time-dependent unitary (canonical) transformation is found which maps the Hamiltonian for a harmonic oscillator with time-dependent real mass and real frequency to that of a generalized harmonic oscillator with time-dependent real mass and imaginary frequency. The latter may be reduced to an ordinary harmonic oscillator by means of another unitary (canonical) transformation. A simple analysis of the resulting system leads to the identification of a previously unknown class of exactly solvable time-dependent oscillators. Furthermore, it is shown how one can apply these results to establish a canonical equivalence between some real and imaginary frequency oscillators. In particular it is shown that a harmonic oscillator whose frequency is constant and whose mass grows linearly in time is canonically equivalent with an oscillator whose frequency changes from being real to imaginary and vice versa repeatedly.Comment: 7 pages, 1 figure include

    Envelope glycoprotein interactions in coronavirus assembly.

    Full text link

    Radiogenic and Muon-Induced Backgrounds in the LUX Dark Matter Detector

    Get PDF
    The Large Underground Xenon (LUX) dark matter experiment aims to detect rare low-energy interactions from Weakly Interacting Massive Particles (WIMPs). The radiogenic backgrounds in the LUX detector have been measured and compared with Monte Carlo simulation. Measurements of LUX high-energy data have provided direct constraints on all background sources contributing to the background model. The expected background rate from the background model for the 85.3 day WIMP search run is (2.6±0.2stat±0.4sys)×10−3(2.6\pm0.2_{\textrm{stat}}\pm0.4_{\textrm{sys}})\times10^{-3}~events~keVee−1_{ee}^{-1}~kg−1^{-1}~day−1^{-1} in a 118~kg fiducial volume. The observed background rate is (3.6±0.4stat)×10−3(3.6\pm0.4_{\textrm{stat}})\times10^{-3}~events~keVee−1_{ee}^{-1}~kg−1^{-1}~day−1^{-1}, consistent with model projections. The expectation for the radiogenic background in a subsequent one-year run is presented.Comment: 18 pages, 12 figures / 17 images, submitted to Astropart. Phy
    • …
    corecore