4,170 research outputs found

    Low speed and angle of attack effects on sonic and near-sonic inlets

    Get PDF
    Tests of the Quiet, Clean Short-Haul Experimental Engine (QCSEE) were conducted to determine the effects of forward velocity and angle of attack on sonic and near-sonic inlet aerodynamic performance penalties and acoustic suppression characteristics. The tests demonstrate that translating centerbody and radial vane sonic inlets, and QCSEE high throat Mach number inlets, can be designed to operate effectively at forward speed and moderate angle of attack with good performance and noise suppression capability. The test equipment and procedures used in conducting the evaluation are described. Results of the tests are presented in tabular form

    Amorphous metallizations for high-temperature semiconductor device applications

    Get PDF
    The initial results of work on a class of semiconductor metallizations which appear to hold promise as primary metallizations and diffusion barriers for high temperature device applications are presented. These metallizations consist of sputter-deposited films of high T sub g amorphous-metal alloys which (primarily because of the absence of grain boundaries) exhibit exceptionally good corrosion-resistance and low diffusion coefficients. Amorphous films of the alloys Ni-Nb, Ni-Mo, W-Si, and Mo-Si were deposited on Si, GaAs, GaP, and various insulating substrates. The films adhere extremely well to the substrates and remain amorphous during thermal cycling to at least 500 C. Rutherford backscattering and Auger electron spectroscopy measurements indicate atomic diffussivities in the 10 to the -19th power sq cm/S range at 450 C

    Annual Survival of Snail Kites in Florida: Radio Telemetry versus Capture-Resighting Data

    Get PDF
    We estimated annual survival of Snail Kites (Rostrhamus sociabilis) in Florida using the Kaplan-Meier estimator with data from 271 radio-tagged birds over a three-year period and capture-recapture (resighting) models with data from 1,319 banded birds over a six-year period. We tested the hypothesis that survival differed among three age classes using both data sources. We tested additional hypotheses about spatial and temporal variation using a combination of data from radio telemetry and single- and multistrata capture-recapture models. Results from these data sets were similar in their indications of the sources of variation in survival, but they differed in some parameter estimates. Both data sources indicated that survival was higher for adults than for juveniles, but they did not support delineation of a subadult age class. Our data also indicated that survival differed among years and regions for juveniles but not for adults. Estimates of juvenile survival using radio telemetry data were higher than estimates using capture-recapture models for two of three years (1992 and 1993). Ancillary evidence based on censored birds indicated that some mortality of radio-tagged juveniles went undetected during those years, resulting in biased estimates. Thus, we have greater confidence in our estimates of juvenile survival using capture-recapture models. Precision of estimates reflected the number of parameters estimated and was surprisingly similar between radio telemetry and single-stratum capture-recapture models, given the substantial differences in sample sizes. Not having to estimate resighting probability likely offsets, to some degree, the smaller sample sizes from our radio telemetry data. Precision of capture-recapture models was lower using multistrata models where region-specific parameters were estimated than using single-stratum models, where spatial variation in parameters was not taken into account

    A depolarization and attenuation experiment using the COMSTAR and CTS satellites

    Get PDF
    Monthly statistical data are presented on ground rainfall rate and attenuation of satellite downlinks at 11.7 GHz, 19.04 GHz, and 28.56 GHz and on cross-polarization isolation at 11.7 GHz. Regression equations for relating isolation to attenuation, attenuation to rain rate, and attenuation at one frequency to attenuation at another frequency are also included. Longer-term statistics are also presented and discussed

    CO2 capture from natural gas combined cycles by CO2 selective membranes

    Get PDF
    This paper performs a techno-economic analysis of natural gas-fired combined cycle (NGCC) power plants integrated with CO2 selective membranes for post-combustion CO2 capture. The configuration assessed is based on a two-membrane system: a CO2 capture membrane that separates the CO2 for final sequestration and a CO2 recycle membrane that selectively recycles CO2 to the gas turbine compressor inlet in order to increase the CO2 concentration in the gas turbine flue gas. Three different membrane technologies with different permeability and selectivity have been investigated. The mass and energy balances are calculated by integrating a power plant model, a membrane model and a CO2 purification unit model. An economic model is then used to estimate the cost of electricity and of CO2 avoided. A sensitivity analysis on the main process parameters and economic assumptions is also performed. It was found that a combination of a high permeability membrane with moderate selectivity as a recycle membrane and a very high selectivity membrane with high permeability used for the capture membrane resulted in the lowest CO2 avoided cost of 75ƂĀ US$/tCO2. This plant features a feed pressure of 1.5ƂĀ bar and a permeate pressure of 0.2ƂĀ bar for the capture membrane. This result suggests that membrane systems can be competitive for CO2 capture from NGCC power plants when compared with MEA absorption. However, to achieve significant advantages with respect to benchmark MEA capture, better membrane permeability and lower costs are needed with respect to the state of the art technology. In addition, due to the selective recycle, the gas turbine operates with a working fluid highly enriched with CO2. This requires redesigning gas turbine components, which may represent a major challenge for commercial deployment

    Transient x-ray diffraction used to diagnose shock compressed Si crystals on the Nova laser

    Get PDF
    Transient x-ray diffraction is used to record time-resolved information about the shock compression of materials. This technique has been applied on Nova shock experiments driven using a hohlraum x-ray drive. Data were recorded from the shock release at the free surface of a Si crystal, as well as from Si at an embedded ablator/Si interface. Modeling has been done to simulate the diffraction data incorporating the strained crystal rocking curves and Bragg diffraction efficiencies. Examples of the data and post-processed simulations are presented

    Corticosterone mediates stressā€related increased intestinal permeability in a regionā€specific manner

    Full text link
    Backgroundā€‚ Chronic psychological stress (CPS) is associated with increased intestinal epithelial permeability and visceral hyperalgesia. It is unknown whether corticosterone (CORT) plays a role in mediating alterations of epithelial permeability in response to CPS. Methodsā€‚ Male rats were subjected to 1ā€h water avoidance (WA) stress or subcutaneous CORT injection daily for 10 consecutive days in the presence or absence of corticoid receptor antagonist RUā€486. The visceromotor response (VMR) to colorectal distension (CRD) was measured. The in situ singleā€pass intestinal perfusion was used to measure intestinal permeability in jejunum and colon simultaneously. Key Resultsā€‚ We observed significant decreases in the levels of glucocorticoid receptor (GR) and tight junction proteins in the colon, but not the jejunum in stressed rats. These changes were largely reproduced by serial CORT injections in control rats and were significantly reversed by RUā€486. Stressed and CORTā€injected rats demonstrated a threefold increase in permeability for PEGā€400 (MW) in colon, but not jejunum and significant increase in VMR to CRD, which was significantly reversed by RUā€486. In addition, no differences in permeability to PEGā€4000 and PEGā€35ā€ƒ000 were detected between control and WA groups. Conclusions & Inferencesā€‚ Our findings indicate that CPS was associated with regionā€specific decrease in epithelial tight junction protein levels in the colon, increased colon epithelial permeability to low molecular weight macromolecules which were largely reproduced by CORT treatment in control rats and prevented by RUā€486. These observations implicate a novel, regionā€specific role for CORT as a mediator of CPSā€induced increased permeability to macromolecules across the colon epithelium.Peer Reviewedhttp://deepblue.lib.umich.edu/bitstream/2027.42/96296/1/nmo.12066.pd
    • ā€¦
    corecore