132 research outputs found

    Technologic (r)evolution leads to detection of more sentinel nodes in patients with melanoma in the head and neck region

    Get PDF
    Sentinel lymph node (SN) biopsy (SNB) has proven to be a valuable tool for staging melanoma patients. Since its introduction in the early 1990s, this procedure has undergone several technologic refinements, including the introduction of SPECT/CT, as well as radioguidance and fluorescence guidance. The purpose of the current study was to evaluate the effect of this technologic evolution on SNB in the head and neck region. The primary endpoint was the false-negative (FN) rate. Secondary endpoints were number of harvested SNs, overall operation time, operation time per harvested SN, and postoperative complications. Methods: A retrospective database was queried for cutaneous head and neck melanoma patients who underwent SNB at The Netherlands Cancer Institute between 1993 and 2016. The implementation of new detection techniques was divided into 4 groups: 1993-2005, with preoperative lymphoscintigraphy and intraoperative use of both a y-ray detection probe and patent blue (n = 30); 2006-2007, with addition of preoperative road maps based on SPECT/CT (n = 15); 2008-2009, with intraoperative use of a portable y-camera (n = 40); and 2010-2016, with addition of near-infrared fluorescence guidance (n = 192). Results: In total, 277 patients were included. At least 1 SN was identified in all patients. A tumor-positive SN was found in 59 patients (21.3%): 10 in group 1 (33.3%), 3 in group 2 (20.0%), 6 in group 3 (15.0%), and 40 in group 4 (20.8%). Regional recurrences in patients with tumor negative SNs resulted in an overall FN rate of 11.9% (group 1, 16.7%; group 2, 0%; group 3, 14.3%; group 4, 11.1%). The number of harvested nodes increased with advancing technologies (P = 0.003), whereas Breslow thickness and operation time per harvested SN decreased (P = 0.003 and P = 0.017, respectively). There was no significant difference in percentage of tumor-positive SNs, overall operation time, and complication rate between the different groups. Conclusion: The use of advanced detection technologies led to a higher number of identified SNs without an increase in overall operation time, possibly indicating an improved surgical efficiency. Operation time per harvested SN decreased; the average FN rate remained 11.9% and was unchanged over 23 y. There was no significant change in postoperative complication rate.Imaging- and therapeutic targets in neoplastic and musculoskeletal inflammatory diseas

    Neoadjuvant cytoreductive treatment with BRAF/MEK inhibition of prior unresectable regionally advanced melanoma to allow complete surgical resection, REDUCTOR: a prospective, single-arm, open-label phase II trial

    Get PDF
    Objective: To evaluate the potency of short-term neoadjuvant cytoreductive therapy with dabrafenib plus trametinib (BRAF and MEK inhibitor) to allow for radical surgical resection in patients with unresectable locally advanced melanoma. Summary Background Data: Approximately 5% of stage III melanoma patients presents with unresectable locally advanced disease, making standard of care with resection followed by adjuvant systemic therapy impossible. Although neoadjuvant targeted therapy has shown promising results in resectable stage III melanoma, its potency to enable surgical resection in patients with primarily unresectable locally advanced stage III melanoma is still unclear. Methods: In this prospective, single-arm, phase II trial, patients with unresectable BRAF-mutated locally advanced stage IIIC or oligometastatic stage IV melanoma were included. After 8 weeks of treatment with dabrafenib and trametinib, evaluation by positron emission tomography/computed tomography and physical examination were used to assess sufficient downsizing of the tumor to enable resection. The primary objective was the percentage of patients who achieved a radical (R0) resection. Results: Between August 2014 and March 2019, 21 patients (20/21 stage IIIC American Joint Committee on Cancer staging manual 7th edition) were included. Planned inclusion of 25 patients was not reached due to slow accrual and changing treatment landscape. Despite this, the predefined endpoint was successfully met. In 18/21 (86%) patients a resection was performed, of which 17 were R0 resections. At a median follow-up of 50 months (interquartile range 37.7-57.1 months), median recurrence-free survival was 9.9 months (95% confidence interval 7.52-not reached) in patients undergoing surgery. Conclusions: This prospective, single-arm, open-label phase II trial, shows neoadjuvant dabrafenib plus trametinib as a potent cytoreductive treatment, allowing radical resection of metastases in 17/21 (81%) patients with prior unresectable locally advanced melanoma.Analysis and support of clinical decision makin

    Pathological response and tumour bed histopathological features correlate with survival following neoadjuvant immunotherapy in stage III melanoma

    Get PDF
    Background: Guidelines for pathological evaluation of neoadjuvant specimens and pathological response categories have been developed by the International Neoadjuvant Melanoma Consortium (INMC). As part of the Optimal Neo-adjuvant Combination Scheme of Ipilimumab and Nivolumab (OpACIN-neo) clinical trial of neoadjuvant combination anti-programmed cell death protein 1/anti-cytotoxic T-Iymphocyte-associated protein 4 immunotherapy for stage III melanoma, we sought to determine interobserver reproducibility of INMC histopathological assessment principles, identify specific tumour bed histopathological features of immunotherapeutic response that correlated with recurrence and relapse-free survival (RFS) and evaluate proposed INMC pathological response categories for predicting recurrence and RFS.Patients and methods: Clinicopathological characteristics of lymph node dissection specimens of 83 patients enrolled in the OpACIN-neo clinical trial were evaluated. Two methods of assessing histological features of immunotherapeutic response were evaluated: the previously described immune-related pathologic response (irPR) score and our novel immunotherapeutic response score (ITRS). For a subset of cases (n = 29), cellular composition of the tumour bed was analysed by flow cytometry.Results: There was strong interobserver reproducibility in assessment of pathological response (kappa = 0.879) and percentage residual viable melanoma (intraclass correlation coefficient = 0.965). The immunotherapeutic response subtype with high fibrosis had the strongest association with lack of recurrence (P = 0.008) and prolonged RFS (P = 0.019). Amongst patients with criteria for pathological non-response (pNR, >50% viable tumour), all who recurred had >= 70% viable melanoma. Higher ITRS and irPR scores correlated with lack of recurrence in the entire cohort (P = 0.002 and P = 70% viable melanoma and incorporating additional criteria of <10% fibrosis subtype of response may identify those at highest risk of recurrence, but requires validation.Analysis and support of clinical decision makin

    Survival and biomarker analyses from the OpACIN-neo and OpACIN neoadjuvant immunotherapy trials in stage III melanoma

    Get PDF
    Neoadjuvant ipilimumab plus nivolumab showed high pathologic response rates (pRRs) in patients with macroscopic stage III melanoma in the phase 1b OpACIN () and phase 2 OpACIN-neo () studies(1,2). While the results are promising, data on the durability of these pathologic responses and baseline biomarkers for response and survival were lacking. After a median follow-up of 4 years, none of the patients with a pathologic response (n = 7/9 patients) in the OpACIN study had relapsed. In OpACIN-neo (n = 86), the 2-year estimated relapse-free survival was 84% for all patients, 97% for patients achieving a pathologic response and 36% for nonresponders (P < 0.001). High tumor mutational burden (TMB) and high interferon-gamma-related gene expression signature score (IFN-gamma score) were associated with pathologic response and low risk of relapse; pRR was 100% in patients with high IFN-gamma score/high TMB; patients with high IFN-gamma score/low TMB or low IFN-gamma score/high TMB had pRRs of 91% and 88%; while patients with low IFN-gamma score/low TMB had a pRR of only 39%. These data demonstrate long-term benefit in patients with a pathologic response and show the predictive potential of TMB and IFN-gamma score. Our findings provide a strong rationale for a randomized phase 3 study comparing neoadjuvant ipilimumab plus nivolumab versus standard adjuvant therapy with antibodies against the programmed cell death protein-1 (anti-PD-1) in macroscopic stage III melanoma

    Search for the Zγ decay mode of new high-mass resonances in pp collisions at √s = 13 TeV with the ATLAS detector

    Get PDF
    This letter presents a search for narrow, high-mass resonances in the Zγ final state with the Z boson decaying into a pair of electrons or muons. The √s = 13 TeV pp collision data were recorded by the ATLAS detector at the CERN Large Hadron Collider and have an integrated luminosity of 140 fb−1. The data are found to be in agreement with the Standard Model background expectation. Upper limits are set on the resonance production cross section times the decay branching ratio into Zγ. For spin-0 resonances produced via gluon–gluon fusion, the observed limits at 95% confidence level vary between 65.5 fb and 0.6 fb, while for spin-2 resonances produced via gluon–gluon fusion (or quark–antiquark initial states) limits vary between 77.4 (76.1) fb and 0.6 (0.5) fb, for the mass range from 220 GeV to 3400 GeV

    Search for a new heavy scalar particle decaying into a Higgs boson and a new scalar singlet in final states with one or two light leptons and a pair of τ-leptons with the ATLAS detector

    Get PDF
    A search for a new heavy scalar particle X decaying into a Standard Model (SM) Higgs boson and a new singlet scalar particle S is presented. The search uses a proton-proton (pp) collision data sample with an integrated luminosity of 140 fb−1 recorded at a centre-of-mass energy of s√ = 13 TeV with the ATLAS detector at the Large Hadron Collider. The most sensitive mass parameter space is explored in X mass ranging from 500 to 1500 GeV, with the corresponding S mass in the range 200–500 GeV. The search selects events with two hadronically decaying τ-lepton candidates from H → τ+τ− decays and one or two light leptons (ℓ = e, μ) from S → VV (V = W, Z) decays while the remaining V boson decays hadronically or to neutrinos. A multivariate discriminant based on event kinematics is used to separate the signal from the background. No excess is observed beyond the expected SM background and 95% confidence level upper limits between 72 fb and 542 fb are derived on the cross-section σ(pp → X → SH) assuming the same SM-Higgs boson-like decay branching ratios for the S → VV decay. Upper limits on the visible cross-sections σ(pp → X → SH → WWττ) and σ(pp → X → SH → ZZττ) are also set in the ranges 3–26 fb and 6–33 fb, respectively

    Measurement of the cross-sections of the electroweak and total production of a Zγ pair in association with two jets in pp collisions at √s = 13 TeV with the ATLAS detector

    Get PDF
    This Letter presents the measurement of the fiducial and differential cross-sections of the electroweak production of a Zγ pair in association with two jets. The analysis uses 140 fb−1 of LHC proton–proton collision data taken at √s = 13 TeV recorded by the ATLAS detector during the years 2015–2018. Events with a Z boson candidate decaying into either an e+e− or μ+μ− pair, a photon and two jets are selected. The electroweak component is extracted by requiring a large dijet invariant mass and by using the information about the centrality of the system and is measured with an observed and expected significance well above five standard deviations. The fiducial pp → Zγ jj cross-section for the electroweak production is measured to be 3.6 ± 0.5 fb. The total fiducial cross-section that also includes contributions where the jets arise from strong interactions is measured to be 16.8+2.0 −1.8 fb. The results are consistent with the Standard Model predictions. Differential cross-sections are also measured using the same events and are compared with parton-shower Monte Carlo simulations. Good agreement is observed between data and predictions

    Search for heavy Higgs bosons with flavour-violating couplings in multi-lepton plus b-jets final states in pp collisions at 13 TeV with the ATLAS detector

    Get PDF
    A search for new heavy scalars with flavour-violating decays in final states with multiple leptons and b-tagged jets is presented. The results are interpreted in terms of a general two-Higgs-doublet model involving an additional scalar with couplings to the top-quark and the three up-type quarks (ρtt, ρtc, and ρtu). The targeted signals lead to final states with either a same-sign top-quark pair, three top-quarks, or four top-quarks. The search is based on a data sample of proton-proton collisions at √s = 13 TeV recorded with the ATLAS detector during Run 2 of the Large Hadron Collider, corresponding to an integrated luminosity of 139 fb−1. Events are categorised depending on the multiplicity of light charged leptons (electrons or muons), total lepton charge, and a deep-neural-network output to enhance the purity of each of the signals. Masses of an additional scalar boson mH between 200 − 630 GeV with couplings ρtt = 0.4, ρtc = 0.2, and ρtu = 0.2 are excluded at 95% confidence level. Additional interpretations are provided in models of R-parity violating supersymmetry, motivated by the recent flavour and (g − 2)μ anomalies

    Search for lepton-favour violation in high-mass dilepton final states using 139 fb−1 of pp collisions at √s = 13 TeV with the ATLAS detector

    Get PDF
    A search is performed for a heavy particle decaying into different-flavour, dilepton final states, using 139 fb−1 of proton-proton collision data at √s = 13 TeV collected in 2015–2018 by the ATLAS detector at the Large Hadron Collider. Final states with electrons, muons and hadronically decaying tau leptons are considered (eμ, eτ or μτ). No significant excess over the Standard Model predictions is observed. Upper limits on the production cross-section are set as a function of the mass of a Z′ boson, a supersymmetric τ-sneutrino, and a quantum black-hole. The observed 95% CL lower mass limits obtained on a typical benchmark model Z′ boson are 5.0 TeV (eμ), 4.0 TeV (eτ), and 3.9 TeV (μτ), respectively
    corecore