1,523 research outputs found

    Widely tunable, non-degenerate three-wave mixing microwave device operating near the quantum limit

    Get PDF
    We present the first experimental realization of a widely frequency tunable, non-degenerate three-wave mixing device for quantum signals at GHz frequency. It is based on a new superconducting building-block consisting of a ring of four Josephson junctions shunted by a cross of four linear inductances. The phase configuration of the ring remains unique over a wide range of magnetic fluxes threading the loop. It is thus possible to vary the inductance of the ring with flux while retaining a strong, dissipation-free, and noiseless non-linearity. The device has been operated in amplifier mode and its noise performance has been evaluated by using the noise spectrum emitted by a voltage biased tunnel junction at finite frequency as a test signal. The unprecedented accuracy with which the crossover between zero-point-fluctuations and shot noise has been measured provides an upper-bound for the noise and dissipation intrinsic to the device.Comment: Accepted for Physical Review Letters. Supplementary material can be found in the source packag

    W-band 0.3W PHEMT MMIC power amplifier module

    Get PDF
    A compact (1.8 by 3.0 by 3.8 cm) WR-10 waveguide amplifier module providing 310-mW power output, 20-dB gain, and 5 GHz of 1-dB bandwidth at a center frequency of 96 GHz is described. The module is comprised of 22 identical PHEMT chips, 4-way microstrip power combiners and dividers, and a 4-way waveguide power combiner

    MMIC low-noise amplifiers and applications above 100 GHz

    Get PDF
    In this paper we will present recent work on low noise amplifiers developed for very high frequencies above 100 GHz. These amplifiers were developed with a unique InP-based HEMT MMIC process. The amplifiers have been developed for both cryogenic and room temperature amplifier applications with state-of-art performance demonstrated from 100 GHz to 215 GHz

    Implementation and evaluation of the VA DPP clinical demonstration: protocol for a multi-site non-randomized hybrid effectiveness-implementation type III trial.

    Get PDF
    BackgroundThe Diabetes Prevention Program (DPP) study showed that lifestyle intervention resulted in a 58% reduction in incidence of type 2 diabetes among individuals with prediabetes. Additional large randomized controlled trials have confirmed these results, and long-term follow-up has shown sustained benefit 10-20 years after the interventions ended. Diabetes is a common and costly disease, especially among Veterans, and despite strong evidence supporting the feasibility of type 2 diabetes prevention, the DPP has not been widely implemented. The first aim of this study will evaluate implementation of the Veterans Affairs (VA) DPP in three VA medical centers. The second aim will assess weight and hemoglobin A1c (A1c) outcomes, and the third aim will determine the cost-effectiveness and budget impact of implementation of the VA DPP from a health system perspective.Methods/designThis partnered multi-site non-randomized systematic assignment study will use a highly pragmatic hybrid effectiveness-implementation type III mixed methods study design. The implementation and administration of the VA DPP will be funded by clinical operations while the evaluation of the VA DPP will be funded by research grants. Seven hundred twenty eligible Veterans will be systematically assigned to the VA DPP clinical demonstration or the usual care VA MOVE!® weight management program. A multi-phase formative evaluation of the VA DPP implementation will be conducted. A theoretical program change model will be used to guide the implementation process and assess applicability and feasibility of the DPP for VA. The Consolidated Framework for Implementation Research (CFIR) will be used to guide qualitative data collection, analysis, and interpretation of barriers and facilitators to implementation. The RE-AIM framework will be used to assess Reach, Effectiveness, Adoption, Implementation, and Maintenance of the VA DPP. Twelve-month weight and A1c change will be evaluated for the VA DPP compared to the VA MOVE!ProgramMediation analyses will be conducted to identify whether program design differences impact outcomes.DiscussionFindings from this pragmatic evaluation will be highly applicable to practitioners who are tasked with implementing the DPP in clinical settings. In addition, findings will determine the effectiveness and cost-effectiveness of the VA DPP in the Veteran population

    Four-photon interference: a realizable experiment to demonstrate violation of EPR postulates for perfect correlations

    Full text link
    Bell's theorem reveals contradictions between the predictions of quantum mechanics and the EPR postulates for a pair of particles only in situations involving imperfect statistical correlations. However, with three or more particles, contradictions emerge even for perfect correlations. We describe an experiment which can be realized in the laboratory, using four-photon entangled states generated by parametric down-conversion, to demonstrate this contradiction at the level of perfect correlations.Comment: publishe

    Quantum tunneling Sb-heterostructure millimeter-wave diodes

    Get PDF
    We have developed a new zero bias millimeter wave diode based on quantum tunneling in an InAs/AlSb/GaSb nanostructure. It is ideal for square law radiometry and passive millimeter wave imaging. Excellent sensitivity has been demonstrated at present up to 110 GHz, with higher bandwidth predicted for smaller area diodes

    Inhibition of αvβ5 Integrin Attenuates Vascular Permeability and Protects against Renal Ischemia-Reperfusion Injury

    Get PDF
    Ischemia-reperfusion injury (IRI) is a leading cause of AKI. This common clinical complication lacks effective therapies and can lead to the development of CKD. The αvβ5 integrin may have an important role in acute injury, including septic shock and acute lung injury. To examine its function in AKI, we utilized a specific function-blocking antibody to inhibit αvβ5 in a rat model of renal IRI. Pretreatment with this anti-αvβ5 antibody significantly reduced serum creatinine levels, diminished renal damage detected by histopathologic evaluation, and decreased levels of injury biomarkers. Notably, therapeutic treatment with the αvβ5 antibody 8 hours after IRI also provided protection from injury. Global gene expression profiling of post-ischemic kidneys showed that αvβ5 inhibition affected established injury markers and induced pathway alterations previously shown to be protective. Intravital imaging of post-ischemic kidneys revealed reduced vascular leak with αvβ5 antibody treatment. Immunostaining for αvβ5 in the kidney detected evident expression in perivascular cells, with negligible expression in the endothelium. Studies in a three-dimensional microfluidics system identified a pericyte-dependent role for αvβ5 in modulating vascular leak. Additional studies showed αvβ5 functions in the adhesion and migration of kidney pericytes in vitro Initial studies monitoring renal blood flow after IRI did not find significant effects with αvβ5 inhibition; however, future studies should explore the contribution of vasomotor effects. These studies identify a role for αvβ5 in modulating injury-induced renal vascular leak, possibly through effects on pericyte adhesion and migration, and reveal αvβ5 inhibition as a promising therapeutic strategy for AKI

    DSA-10: A prototype array for localizing fast radio bursts

    Get PDF
    The Deep Synoptic Array 10 dish prototype is an instrument designed to detect and localise fast radio bursts with arcsecond accuracy in real time. Deployed at Owens Valley Radio Observatory, it consists of ten 4.5m diameter dishes, equipped with a 250MHz bandwidth dual polarisation receiver, centered at 1.4GHz. The 20 input signals are digitised and field programmable gate arrays are used to transform the data to the frequency domain and transmit it over ethernet. A series of computer servers buffer both raw data samples and perform a real time search for fast radio bursts on the incoherent sum of all inputs. If a pulse is detected, the raw data surrounding the pulse is written to disk for coherent processing and imaging. The prototype system was operational from June 2017 - February 2018 conducting a drift scan search. Giant pulses from the Crab pulsar were used to test the detection and imaging pipelines. The 10-dish prototype system was brought online again in March 2019, and will gradually be replaced with the new DSA-110, a 110-dish system, over the next two years to improve sensitivity and localisation accuracy.Comment: 10 pages, 13 figures, accepted by MNRA

    W-band 0.3W PHEMT MMIC power amplifier module

    Get PDF
    A compact (1.8 by 3.0 by 3.8 cm) WR-10 waveguide amplifier module providing 310-mW power output, 20-dB gain, and 5 GHz of 1-dB bandwidth at a center frequency of 96 GHz is described. The module is comprised of 22 identical PHEMT chips, 4-way microstrip power combiners and dividers, and a 4-way waveguide power combiner
    corecore