78 research outputs found
Enhancing intraoperative tumor delineation with multispectral short-wave infrared fluorescence imaging and machine learning
SIGNIFICANCE: Fluorescence-guided surgery (FGS) provides specific real-time visualization of tumors, but intensity-based measurement of fluorescence is prone to errors. Multispectral imaging (MSI) in the short-wave infrared (SWIR) has the potential to improve tumor delineation by enabling machine-learning classification of pixels based on their spectral characteristics. AIM: Determine whether MSI can be applied to FGS and combined with machine learning to provide a robust method for tumor visualization. APPROACH: A multispectral SWIR fluorescence imaging device capable of collecting data from six spectral filters was constructed and deployed on neuroblastoma (NB) subcutaneous xenografts ( n = 6 ) after the injection of a NB-specific NIR-I fluorescent probe (Dinutuximab-IRDye800). We constructed image cubes representing fluorescence collected from ∼ 850 to 1450 nm and compared the performance of seven learning-based methods for pixel-by-pixel classification, including linear discriminant analysis, k -nearest neighbor classification, and a neural network. RESULTS: The spectra of tumor and non-tumor tissue were subtly different and conserved between individuals. In classification, a combine principal component analysis and k -nearest-neighbor approach with area under curve normalization performed best, achieving 97.5% per-pixel classification accuracy (97.1%, 93.5%, and 99.2% for tumor, non-tumor tissue and background, respectively). CONCLUSIONS: The development of dozens of new imaging agents provides a timely opportunity for multispectral SWIR imaging to revolutionize next-generation FGS
Recommended from our members
A roadmap for the clinical implementation of optical-imaging biomarkers
Clinical workflows for the non-invasive detection and characterization of disease states could benefit from optical-imaging biomarkers. In this Perspective, we discuss opportunities and challenges towards the clinical implementation of optical-imaging biomarkers for the early detection of cancer by analysing two case studies: the assessment of skin lesions in primary care, and the surveillance of patients with Barrett’s oesophagus in specialist care. We stress the importance of technical and biological validations and clinical-utility assessments, and the need to address implementation bottlenecks. In addition, we define a translational roadmap for the widespread clinical implementation of optical imaging-technologies
Targeted Multispectral Filter Array Design for Endoscopic Cancer Detection in the Gastrointestinal Tract
Colour differences between healthy and diseased tissue in the
gastrointestinal tract are detected visually by clinicians during white light
endoscopy (WLE); however, the earliest signs of disease are often just a
slightly different shade of pink compared to healthy tissue. Here, we propose
to target alternative colours for imaging to improve contrast using custom
multispectral filter arrays (MSFAs) that could be deployed in an endoscopic
chip-on-tip configuration. Using an open-source toolbox, Opti-MSFA, we examined
the optimal design of MSFAs for early cancer detection in the gastrointestinal
tract. The toolbox was first extended to use additional classification models
(k-Nearest Neighbour, Support Vector Machine, and Spectral Angle Mapper). Using
input spectral data from published clinical trials examining the oesophagus and
colon, we optimised the design of MSFAs with 3 to 9 different bands. We
examined the variation of the spectral and spatial classification accuracy as a
function of number of bands. The MSFA designs have high classification
accuracies, suggesting that future implementation in endoscopy hardware could
potentially enable improved early detection of disease in the gastrointestinal
tract during routine screening and surveillance. Optimal MSFA configurations
can achieve similar classification accuracies as the full spectral data in an
implementation that could be realised in far simpler hardware. The reduced
number of spectral bands could enable future deployment of multispectral
imaging in an endoscopic chip-on-tip configuration.Comment: 29 page
A clinically translatable hyperspectral endoscopy (HySE) system for imaging the gastrointestinal tract.
Hyperspectral imaging (HSI) enables visualisation of morphological and biochemical information, which could improve disease diagnostic accuracy. Unfortunately, the wide range of image distortions that arise during flexible endoscopy in the clinic have made integration of HSI challenging. To address this challenge, we demonstrate a hyperspectral endoscope (HySE) that simultaneously records intrinsically co-registered hyperspectral and standard-of-care white light images, which allows image distortions to be compensated computationally and an accurate hyperspectral data cube to be reconstructed as the endoscope moves in the lumen. Evaluation of HySE performance shows excellent spatial, spectral and temporal resolution and high colour fidelity. Application of HySE enables: quantification of blood oxygenation levels in tissue mimicking phantoms; differentiation of spectral profiles from normal and pathological ex vivo human tissues; and recording of hyperspectral data under freehand motion within an intact ex vivo pig oesophagus model. HySE therefore shows potential for enabling HSI in clinical endoscopy
Short-wave infrared imaging enables high-contrast fluorescence-guided surgery in neuroblastoma
Fluorescence-guided surgery is set to play a pivotal role in the intraoperative management of pediatric tumors. Short-wave infrared imaging (SWIR) has advantages over conventional near-infrared I (NIR-I) imaging with reduced tissue scattering and autofluorescence. Here, two NIR-I dyes (IRDye800CW and IR12), with long tails emitting in the SWIR range, were conjugated with a clinical-grade anti-GD2 monoclonal antibody (Dinutuximab-beta) to compare NIR-I and SWIR imaging for neuroblastoma surgery. A first-of-its-kind multispectral NIR-I/SWIR fluorescence imaging device was constructed to allow an objective comparison between the two imaging windows. Conjugates were first characterized in vitro. Tissue-mimicking phantoms, imaging specimens of known geometric and material composition, were used to assess the sensitivity and depth penetration of the NIR-I/SWIR device, showing a minimum detectable volume of ~0.9 mm3 and depth penetration up to 3 mm. In vivo, fluorescence imaging using the NIR-I/SWIR device showed a high tumor-to-background ratio (TBR) for both dyes, with anti-GD2-IR800 being significantly brighter than anti-GD2-IR12. Crucially, the system enabled higher TBR at SWIR wavelengths than at NIR-I wavelengths, verifying SWIR imaging enables high-contrast delineation of tumor margins. This work demonstrates that by combining the high-specificity of anti-GD2 antibodies with the availability and translatability of existing NIR-I dyes, along with the advantages of SWIR in terms of depth and tumor signal-to-background ratio, GD2-targeted NIR-I/SWIR-guided surgery could improve the treatment of neuroblastoma patients, warranting investigation in future clinical trials
Fortnightly changes in water transport direction across the mouth of a narrow estuary
This research investigates the dynamics of the axial
tidal flow and residual circulation at the lower Guadiana
Estuary, south Portugal, a narrow mesotidal estuary with low
freshwater inputs. Current data were collected near the deepest
part of the channel for 21 months and across the channel
during two (spring and neap) tidal cycles. Results indicate
that at the deep channel, depth-averaged currents are stronger
and longer during the ebb at spring and during the flood at
neap, resulting in opposite water transport directions at a
fortnightly time scale. The net water transport across the entire
channel is up-estuary at spring and down-estuary at neap, i.e.,
opposite to the one at the deep channel. At spring tide, when
the estuary is considered to be well mixed, the observed
pattern of circulation (outflow in the deep channel, inflow
over the shoals) results from the combination of the Stokes
transport and compensating return flow, which varies laterally
with the bathymetry. At neap tide (in particular for those of
lowest amplitude each month), inflows at the deep channel are
consistently associated with the development of gravitational
circulation. Comparisons with previous studies suggest that
the baroclinic pressure gradient (rather than internal tidal
asymmetries) is the main driver of the residual water transport.
Our observations also indicate that the flushing out of the
water accumulated up-estuary (at spring) may also produce
strong unidirectional barotropic outflow across the entire
channel around neap tide.info:eu-repo/semantics/publishedVersio
Shattered pellet injection experiments at JET in support of the ITER disruption mitigation system design
A series of experiments have been executed at JET to assess the efficacy of the newly installed shattered pellet injection (SPI) system in mitigating the effects of disruptions. Issues, important for the ITER disruption mitigation system, such as thermal load mitigation, avoidance of runaway electron (RE) formation, radiation asymmetries during thermal quench mitigation, electromagnetic load control and RE energy dissipation have been addressed over a large parameter range. The efficiency of the mitigation has been examined for the various SPI injection strategies. The paper summarises the results from these JET SPI experiments and discusses their implications for the ITER disruption mitigation scheme
The role of ETG modes in JET-ILW pedestals with varying levels of power and fuelling
We present the results of GENE gyrokinetic calculations based on a series of JET-ITER-like-wall (ILW) type I ELMy H-mode discharges operating with similar experimental inputs but at different levels of power and gas fuelling. We show that turbulence due to electron-temperature-gradient (ETGs) modes produces a significant amount of heat flux in four JET-ILW discharges, and, when combined with neoclassical simulations, is able to reproduce the experimental heat flux for the two low gas pulses. The simulations plausibly reproduce the high-gas heat fluxes as well, although power balance analysis is complicated by short ELM cycles. By independently varying the normalised temperature gradients (omega(T)(e)) and normalised density gradients (omega(ne )) around their experimental values, we demonstrate that it is the ratio of these two quantities eta(e) = omega(Te)/omega(ne) that determines the location of the peak in the ETG growth rate and heat flux spectra. The heat flux increases rapidly as eta(e) increases above the experimental point, suggesting that ETGs limit the temperature gradient in these pulses. When quantities are normalised using the minor radius, only increases in omega(Te) produce appreciable increases in the ETG growth rates, as well as the largest increases in turbulent heat flux which follow scalings similar to that of critical balance theory. However, when the heat flux is normalised to the electron gyro-Bohm heat flux using the temperature gradient scale length L-Te, it follows a linear trend in correspondence with previous work by different authors
A control oriented strategy of disruption prediction to avoid the configuration collapse of tokamak reactors
The objective of thermonuclear fusion consists of producing electricity from the coalescence of light nuclei in high temperature plasmas. The most promising route to fusion envisages the confinement of such plasmas with magnetic fields, whose most studied configuration is the tokamak. Disruptions are catastrophic collapses affecting all tokamak devices and one of the main potential showstoppers on the route to a commercial reactor. In this work we report how, deploying innovative analysis methods on thousands of JET experiments covering the isotopic compositions from hydrogen to full tritium and including the major D-T campaign, the nature of the various forms of collapse is investigated in all phases of the discharges. An original approach to proximity detection has been developed, which allows determining both the probability of and the time interval remaining before an incoming disruption, with adaptive, from scratch, real time compatible techniques. The results indicate that physics based prediction and control tools can be developed, to deploy realistic strategies of disruption avoidance and prevention, meeting the requirements of the next generation of devices.Confining plasma and managing disruptions in tokamak devices is a challenge. Here the authors demonstrate a method predicting and possibly preventing disruptions and macroscopic instabilities in tokamak plasma using data from JET
New H-mode regimes with small ELMs and high thermal confinement in the Joint European Torus
New H-mode regimes with high confinement, low core impurity accumulation, and small edge-localized mode perturbations have been obtained in magnetically confined plasmas at the Joint European Torus tokamak. Such regimes are achieved by means of optimized particle fueling conditions at high input power, current, and magnetic field, which lead to a self-organized state with a strong increase in rotation and ion temperature and a decrease in the edge density. An interplay between core and edge plasma regions leads to reduced turbulence levels and outward impurity convection. These results pave the way to an attractive alternative to the standard plasmas considered for fusion energy generation in a tokamak with a metallic wall environment such as the ones expected in ITER.& nbsp;Published under an exclusive license by AIP Publishing
- …