349 research outputs found

    Apparatus for sensor failure detection and correction in a gas turbine engine control system

    Get PDF
    A gas turbine engine control system maintains a selected level of engine performance despite the failure or abnormal operation of one or more engine parameter sensors. The control system employs a continuously updated engine model which simulates engine performance and generates signals representing real time estimates of the engine parameter sensor signals. The estimate signals are transmitted to a control computational unit which utilizes them in lieu of the actual engine parameter sensor signals to control the operation of the engine. The estimate signals are also compared with the corresponding actual engine parameter sensor signals and the resulting difference signals are utilized to update the engine model. If a particular difference signal exceeds specific tolerance limits, the difference signal is inhibited from updating the model and a sensor failure indication is provided to the engine operator

    Evolving Landscape of Carbapenem-Resistant

    Get PDF
    OBJECTIVES: The increased identification of carbapenem-resistant METHODS: A total of 169 CR-PA isolated from clinical specimens at a single centre in Houston, TX, USA were studied. Among them, 61 isolates collected between 1999 and 2005 were defined as historical strains, and 108 collected between 2017 and 2018 were defined as contemporary strains. Antimicrobial susceptibilities against selected β-lactams was determined. WGS data were used for the identification of antimicrobial resistance determinants and phylogenetic analysis. RESULTS: Non-susceptibility to ceftolozane/tazobactam and ceftazidime/avibactam increased from 2% (1/59) to 17% (18/108) and from 7% (4/59) to 17% (18/108) from the historical to the contemporary collection, respectively. Carbapenemase genes, which were not identified in the historical collection, were harboured by 4.6% (5/108) of the contemporary strains, and the prevalence of ESBL genes also increased from 3.3% (2/61) to 16% (17/108). Genes encoding acquired β-lactamases were largely confined to the high-risk clones. Among ceftolozane/tazobactam-resistant isolates, non-susceptibility to ceftazidime/avibactam, imipenem/relebactam and cefiderocol was observed in 94% (15/16), 56% (9/16) and 12.5% (2/16), respectively. Resistance to ceftolozane/tazobactam and imipenem/relebactam was primarily associated with the presence of exogenous β-lactamases. CONCLUSIONS: Acquisition of exogenous carbapenemases and ESBLs may be a worrisome trend i

    From Quantum Systems to L-Functions: Pair Correlation Statistics and Beyond

    Full text link
    The discovery of connections between the distribution of energy levels of heavy nuclei and spacings between prime numbers has been one of the most surprising and fruitful observations in the twentieth century. The connection between the two areas was first observed through Montgomery's work on the pair correlation of zeros of the Riemann zeta function. As its generalizations and consequences have motivated much of the following work, and to this day remains one of the most important outstanding conjectures in the field, it occupies a central role in our discussion below. We describe some of the many techniques and results from the past sixty years, especially the important roles played by numerical and experimental investigations, that led to the discovery of the connections and progress towards understanding the behaviors. In our survey of these two areas, we describe the common mathematics that explains the remarkable universality. We conclude with some thoughts on what might lie ahead in the pair correlation of zeros of the zeta function, and other similar quantities.Comment: Version 1.1, 50 pages, 6 figures. To appear in "Open Problems in Mathematics", Editors John Nash and Michael Th. Rassias. arXiv admin note: text overlap with arXiv:0909.491

    A Realistic Validation Study of a New Nitrogen Multiple-Breath Washout System

    Get PDF
    Background For reliable assessment of ventilation inhomogeneity, multiple-breath washout (MBW) systems should be realistically validated. We describe a new lung model for in vitro validation under physiological conditions and the assessment of a new nitrogen (N2)MBW system. Methods The N2MBW setup indirectly measures the N2 fraction (FN2) from main-stream carbon dioxide (CO2) and side-stream oxygen (O2) signals: FN2 = 1−FO2−FCO2−FArgon. For in vitro N2MBW, a double chamber plastic lung model was filled with water, heated to 37°C, and ventilated at various lung volumes, respiratory rates, and FCO2. In vivo N2MBW was undertaken in triplets on two occasions in 30 healthy adults. Primary N2MBW outcome was functional residual capacity (FRC). We assessed in vitro error (√[difference]2) between measured and model FRC (100–4174 mL), and error between tests of in vivo FRC, lung clearance index (LCI), and normalized phase III slope indices (Sacin and Scond). Results The model generated 145 FRCs under BTPS conditions and various breathing patterns. Mean (SD) error was 2.3 (1.7)%. In 500 to 4174 mL FRCs, 121 (98%) of FRCs were within 5%. In 100 to 400 mL FRCs, the error was better than 7%. In vivo FRC error between tests was 10.1 (8.2)%. LCI was the most reproducible ventilation inhomogeneity index. Conclusion The lung model generates lung volumes under the conditions encountered during clinical MBW testing and enables realistic validation of MBW systems. The new N2MBW system reliably measures lung volumes and delivers reproducible LCI values

    Effect of cadence on locomotor–respiratory coupling during upper-body exercise

    Get PDF
    Introduction: Asynchronous arm-cranking performed at high cadences elicits greater cardiorespiratory responses compared to low cadences. This has been attributed to increased postural demand and locomotor–respiratory coupling (LRC), and yet, this has not been empirically tested. This study aimed to assess the effects of cadence on cardiorespiratory responses and LRC during upper-body exercise. Methods: Eight recreationally-active men performed arm-cranking exercise at moderate and severe intensities that were separated by 10 min of rest. At each intensity, participants exercised for 4 min at each of three cadences (50, 70, and 90 rev min−1) in a random order, with 4 min rest-periods applied in-between cadences. Exercise measures included LRC via whole- and half-integer ratios, cardiorespiratory function, perceptions of effort (RPE and dyspnoea), and diaphragm EMG using an oesophageal catheter. Results: The prevalence of LRC during moderate exercise was highest at 70 vs. 50 rev min−1 (27 ± 10 vs. 13 ± 9%, p = 0.000) and during severe exercise at 90 vs. 50 rev min−1 (24 ± 7 vs. 18 ± 5%, p = 0.034), with a shorter inspiratory time and higher mean inspiratory flow (p < 0.05) at higher cadences. During moderate exercise, (Formula presented.) and fC were higher at 90 rev min−1 (p < 0.05) relative to 70 and 50 rev min−1 ((Formula presented.) 1.19 ± 0.25 vs. 1.05 ± 0.21 vs. 0.97 ± 0.24 L min−1; fC 116 ± 11 vs. 101 ± 13 vs. 101 ± 12 b min−1), with concomitantly elevated dyspnoea. There were no discernible cadence-mediated effects on diaphragm EMG. Conclusion: Participants engage in LRC to a greater extent at moderate-high cadences which, in turn, increase respiratory airflow. Cadence rate should be carefully considered when designing aerobic training programmes involving the upper-limbs

    A randomised controlled trial of supplemental oxygen versus medical air during exercise training in people with chronic obstructive pulmonary disease: Supplemental oxygen in pulmonary rehabilitation trial (SuppORT) (Protocol)

    Get PDF
    © 2016 Alison et al. Background: Oxygen desaturation during exercise is common in people with chronic obstructive pulmonary disease (COPD). The aim of the study is to determine, in people with COPD who desaturate during exercise, whether supplemental oxygen during an eight-week exercise training program is more effective than medical air (sham intervention) in improving exercise capacity and health-related quality of life both at the completion of training and at six-month follow up. Methods/Design: This is a multi-centre randomised controlled trial with concealed allocation, blinding of participants, exercise trainers and assessors, and intention-to-treat analysis. 110 people with chronic obstructive pulmonary disease who demonstrate oxygen desaturation lower than 90 % during the six-minute walk test will be recruited from pulmonary rehabilitation programs in seven teaching hospitals in Australia. People with chronic obstructive pulmonary disease on long term oxygen therapy will be excluded. After confirmation of eligibility and baseline assessment, participants will be randomised to receive either supplemental oxygen or medical air during an eight-week supervised treadmill and cycle exercise training program, three times per week for eight weeks, in hospital outpatient settings. Primary outcome measures will be endurance walking capacity assessed by the endurance shuttle walk test and health-related quality of life assessed by the Chronic Respiratory Disease Questionnaire. Secondary outcomes will include peak walking capacity measured by the incremental shuttle walk test, dyspnoea via the Dyspnoea-12 questionnaire and physical activity levels measured over seven days using an activity monitor. All outcomes will be measured at baseline, completion of training and at six-month follow up. Discussion: Exercise training is an essential component of pulmonary rehabilitation for people with COPD. This study will determine whether supplemental oxygen during exercise training is more effective than medical air in improving exercise capacity and health-related quality of life in people with COPD who desaturate during exercise. Trial registration: Australian New Zealand Clinical Trials Registry ACTRN12612000395831 , 5th Jan,201
    • …
    corecore