698 research outputs found
Recommended from our members
Extending Murty interferometry to the Terahertz part of the spectrum
We discuss some novel technologies that enable the implementation of shearing interferometry at the terahertz part of the spectrum. Possible applications include the direct measurement of lens parameters, the measurement of refractive index of materials that are transparent to terahertz frequencies, determination of homogeneity of samples, measurement of optical distortions and the non-contact evaluation of thermal expansion coefficient of materials buried inside media that are opaque to optical or infrared frequencies but transparent to THz frequencies. The introduction of a shear to a Gaussian free-space propagating terahertz beam in a controlled manner also makes possible a range of new encoding and optical signal processing modalities
Recommended from our members
System identification algorithms for the analysis of dielectric responses from broadband spectroscopies
We discuss the modeling of dielectric responses for an electromagnetically excited network of capacitors and resistors using a systems identification framework. Standard models that assume integral order dynamics are augmented to incorporate fractional order dynamics. This enables us to relate more faithfully the modeled responses to those reported in the Dielectrics literature
Optical properties of tissue measured using terahertz pulsed imaging.
The first demonstrations of terahertz imaging in biomedicine were made several years ago, but few data are available on the optical properties of human tissue at terahertz frequencies. A catalogue of these properties has been established to estimate variability and determine the practicality of proposed medical applications in terms of penetration depth, image contrast and reflection at boundaries. A pulsed terahertz imaging system with a useful bandwidth 0.5-2.5 THz was used. Local ethical committee approval was obtained. Transmission measurements were made through tissue slices of thickness 0.08 to 1 mm, including tooth enamel and dentine, cortical bone, skin, adipose tissue and striated muscle. The mean and standard deviation for refractive index and linear attenuation coefficient, both broadband and as a function of frequency, were calculated. The measurements were used in simple models of the transmission, reflection and propagation of terahertz radiation in potential medical applications. Refractive indices ranged from 1.5 ± 0.5 for adipose tissue to 3.06 ± 0.09 for tooth enamel. Significant differences (P<0.05) were found between the broadband refractive indices of a number of tissues. Terahertz radiation is strongly absorbed in tissue so reflection imaging, which has lower penetration requirements than transmission, shows promise for dental or dermatological applications
Recommended from our members
High signal to noise ratio THz spectroscopy with ASOPS and signal processing schemes for mapping and controlling molecular and bulk relaxation processes
Asynchronous Optical Sampling has the potential to improve signal to noise ratio in
THz transient sperctrometry. The design of an inexpensive control scheme for synchronising
two femtosecond pulse frequency comb generators at an offset frequency of 20 kHz is
discussed. The suitability of a range of signal processing schemes adopted from the Systems
Identification and Control Theory community for further processing recorded THz transients in
the time and frequency domain are outlined. Finally, possibilities for femtosecond pulse
shaping using genetic algorithms are mentioned
An inverse approach to Einstein's equations for non-conducting fluids
We show that a flow (timelike congruence) in any type warped product
spacetime is uniquely and algorithmically determined by the condition of zero
flux. (Though restricted, these spaces include many cases of interest.) The
flow is written out explicitly for canonical representations of the spacetimes.
With the flow determined, we explore an inverse approach to Einstein's
equations where a phenomenological fluid interpretation of a spacetime follows
directly from the metric irrespective of the choice of coordinates. This
approach is pursued for fluids with anisotropic pressure and shear viscosity.
In certain degenerate cases this interpretation is shown to be generically not
unique. The framework developed allows the study of exact solutions in any
frame without transformations. We provide a number of examples, in various
coordinates, including spacetimes with and without unique interpretations. The
results and algorithmic procedure developed are implemented as a computer
algebra program called GRSource.Comment: 9 pages revtex4. Final form to appear in Phys Rev
A Randomized, Placebo-Controlled, Double-Blind Trial of the Effect of Combined Therapy With Deferoxamine and Deferiprone on Myocardial Iron in Thalassemia Major Using Cardiovascular Magnetic Resonance
Backgroundâ
Cardiac complications secondary to iron overload are the leading cause of death in ÎČ-thalassemia major. Approximately two thirds of patients maintained on the parenteral iron chelator deferoxamine have myocardial iron loading. The oral iron chelator deferiprone has been demonstrated to remove myocardial iron, and it has been proposed that in combination with deferoxamine it may have additional effect.
Methods and Resultsâ
Myocardial iron loading was assessed with the use of myocardial T2* cardiovascular magnetic resonance in 167 patients with thalassemia major receiving standard maintenance chelation monotherapy with subcutaneous deferoxamine. Of these patients, 65 with mild to moderate myocardial iron loading (T2* 8 to 20 ms) entered the trial with continuation of subcutaneous deferoxamine and were randomized to receive additional oral placebo (deferoxamine group) or oral deferiprone 75 mg/kg per day (combined group). The primary end point was the change in myocardial T2* over 12 months. Secondary end points of endothelial function (flow-mediated dilatation of the brachial artery) and cardiac function were also measured with cardiovascular magnetic resonance. There were significant improvements in the combined treatment group compared with the deferoxamine group in myocardial T2* (ratio of change in geometric means 1.50 versus 1.24;
P
=0.02), absolute left ventricular ejection fraction (2.6% versus 0.6%;
P
=0.05), and absolute endothelial function (8.8% versus 3.3%;
P
=0.02). There was also a significantly greater improvement in serum ferritin in the combined group (â976 versus â233 ÎŒg/L;
P
<0.001).
Conclusionsâ
In comparison to the standard chelation monotherapy of deferoxamine, combination treatment with additional deferiprone reduced myocardial iron and improved the ejection fraction and endothelial function in thalassemia major patients with mild to moderate cardiac iron loading
Recommended from our members
Do in vivo terahertz imaging systems comply with safety guidelines?
Techniques for the coherent generation and detection of electromagnetic radiation in the far infrared, or terahertz, region of the electromagnetic spectrum have recently developed rapidly and may soon be applied for in vivo medical imaging. Both continuous wave and pulsed imaging systems are under development, with terahertz pulsed imaging being the more common method. Typically a pump and probe technique is used, with picosecond pulses of terahertz radiation generated from femtosecond infrared laser pulses, using an antenna or nonlinear crystal. After interaction with the subject either by transmission or reflection, coherent detection is achieved when the terahertz beam is combined with the probe laser beam. Raster scanning of the subject leads to an image data set comprising a time series representing the pulse at each pixel. A set of parametric images may be calculated, mapping the values of various parameters calculated from the shape of the pulses. A safety analysis has been performed, based on current guidelines for skin exposure to radiation of wavelengths 2.6 mum-20 mm (15 GHz-115 THz), to determine the maximum permissible exposure (MPE) for such a terahertz imaging system. The international guidelines for this range of wavelengths are drawn from two U.S. standards documents. The method for this analysis was taken from the American National Standard for the Safe Use of Lasers (ANSI Z136.1), and to ensure a conservative analysis, parameters were drawn from both this standard and from the IEEE Standard for Safety Levels with Respect to Human Exposure to Radio Frequency Electromagnetic Fields (C95.1). The calculated maximum permissible average beam power was 3 mW, indicating that typical terahertz imaging systems are safe according to the current guidelines. Further developments may however result in systems that will exceed the calculated limit. Furthermore, the published MPEs for pulsed exposures are based on measurements at shorter wavelengths and with pulses of longer duration than those used in terahertz pulsed imaging systems, so the results should be treated with caution
Complete solutions to the metric of spherically collapsing dust in an expanding spacetime with a cosmological constant
We present semi-analytical solutions to the background equations describing
the Lema\^itre-Tolman-Bondi (LTB) metric as well as the homogeneous Friedmann
equations, in the presence of dust, curvature and a cosmological constant
Lambda. For none of the presented solutions any numerical integration has to be
performed. All presented solutions are given for expanding and collapsing
phases, preserving continuity in time and radius. Hence, these solutions
describe the complete space time of a collapsing spherical object in an
expanding universe. In the appendix we present for completeness a solution of
the Friedmann equations in the additional presence of radiation, only valid for
the Robertson-Walker metric.Comment: 23 pages, one figure. Numerical module for evaluation of the
solutions released at
http://web.physik.rwth-aachen.de/download/valkenburg/ColLambda/ Matches
published version, published under Open Access. Note change of titl
The Refederalization of American Health Care
Peer Reviewedhttp://deepblue.lib.umich.edu/bitstream/2027.42/69090/2/10.1177_107755878704400103.pd
Simulacral, genealogical, auratic and representational failure: Bushman authenticity as methodological collapse
This article engages with the concept of authenticity as deployed in anthropology. The first section critiques authenticity as a simple reference to cultural purity, a traditional isomorphism or historical verisimilitude or as an âethnographic authenticityâ. Demarcation of authenticity must take into account philosophical literature that argues that authenticity is an existential question of the âmodernâ era. Thus, authenticity is offered to us as individuals as a remedy for the maladies of modernity: alienation, anomie and alterity. Authenticity is then discussed as a question of value within an economy of cultural politics that often draws on simulacra, creating cultural relics of dubious origin. The final section discusses various methodological failures and problematiques that are highlighted by the concern for, and scrutiny of, authenticity. The first is the simulacral failure. The subjects of anthropology are mostly real flesh-and-blood people-on-the-ground with real needs. In contrast is the simulacral subject, the brand, the tourist image, the media image or the ever-familiar hyper-real bushmen. Lastly, the article considers what Spivak calls âwithholdingâ â a resistance to authentic representation by the Other. Resistance suggests a need for a radically altered engagement with the Other that includes both a deepening, and an awareness, of anthropology as a process of common ontological unfolding
- âŠ