50,845 research outputs found

    The application of remote sensing techniques: Technical and methodological issues

    Get PDF
    Capabilities and limitations of modern imaging electromagnetic sensor systems are outlined, and the products of such systems are compared with those of the traditional aerial photographic system. Focus is given to the interface between the rapidly developing remote sensing technology and the information needs of operational agencies, and communication gaps are shown to retard early adoption of the technology by these agencies. An assessment is made of the current status of imaging remote sensors and their potential for the future. Public sources of remote sensor data and several cost comparisons are included

    Organs from animals for man

    Get PDF
    In the following review some of the problems of xenotransplantation shall be discussed, based on the few experimental data available so far and on reports in the literature describing investigations which may be of importance for xenotransplantation. The impact of gravity on the upright posture of man versus almost all other mammals, the dysfunction between enzymes and hormones in different species and the lack of interactions between interleukins, cytokines and vasoactive substances will be taken into consideration. The question must be asked whether different levels of carrier molecules or serum proteins play a role in the physiological network. Even though the development of transgenic animals or other imaginative manipulations may lead to the acceptance of any type of xenografted organ, it has to be established for how long the products of the xenografts are able to act in the multifactorial orchestra. We are far from understanding xenogeneic molecular mechanisms involved in toxicity, necrosis and apoptosis or even reperfusion injury and ischemia in addition to the immediate mechanisms of the hyperacute xenogeneic rejection. Here, cell adhesion, blood clotting and vasomotion collide and bring micro-and macrocirculation to a standstill. All types of xenogeneic immunological mechanisms studied so far were found to have a more serious impact than those seen in allogeneic transplantation. In addition we are now only beginning to understand that so-called immunological parameters in allogeneic mechanisms act also in a true physiological manner in the xenogeneic situation. These molecular mechanisms occur behind the curtain of hyperacute, accelerated, acute or chronic xenograft rejection of which only some folds have been lifted to allow glimpses of part of the total scene. Other obstacles are likely to arise when long-term survival is achieved. These obstacles include retroviral infections, transfer of prions and severe side effects of the massive immunosuppression which will be needed. Moral, ethical and religious concerns are under debate and the species-specific production of proteins of the foreign donor species developed for clinical use suddenly appears to be a greater problem than anticipated

    A Skylab program for the International Hydrological Decade (IHD)

    Get PDF
    There are no author-identified significant results in this report

    Imaging Pauli repulsion in scanning tunneling microscopy

    Get PDF
    A scanning tunneling microscope (STM) has been equipped with a nanoscale force sensor and signal transducer composed of a single D2 molecule that is confined in the STM junction. The uncalibrated sensor is used to obtain ultra-high geometric image resolution of a complex organic molecule adsorbed on a noble metal surface. By means of conductance-distance spectroscopy and corresponding density functional calculations the mechanism of the sensor/transducer is identified. It probes the short-range Pauli repulsion and converts this signal into variations of the junction conductance.Comment: 4 pages, 4 figures, accepted to Phys. Rev. Let

    Experimental studies of hypersonic boundary-layer transition and effects of wind tunnel disturbances

    Get PDF
    Boundary layer transition data on cones and free stream disturbance levels were measured in a hypersonic wind tunnel and Mach 8 variable density hypersonic tunnel. Transition data were obtained by using different conical models and techniques for detecting the location of transition. The disturbance levels were measured by using hot wire anemometry and pressure transducers. The transition Reynolds numbers obtained from the tests correlated well when the fluctuating pressures measured at the surface of conical models were used as a correlating parameter

    A foam model highlights the differences of the macro- and microrheology of respiratory horse mucus

    Get PDF
    Native horse mucus is characterized with micro- and macrorheology and compared to hydroxyethylcellulose (HEC) gel as a model. Both systems show comparable viscoelastic properties on the microscale and for the HEC the macrorheology is in good agreement with the microrheology. For the mucus, the viscoelastic moduli on the macroscale are several orders of magnitude larger than on the microscale. Large amplitude oscillatory shear experiments show that the mucus responds nonlinearly at much smaller deformations than HEC. This behavior fosters the assumption that the mucus has a foam like structure on the microscale compared to the typical mesh like structure of the HEC, a model that is supported by cryogenic-scanning-electron-microscopy (CSEM) images. These images allow also to determine the relative amount of volume that is occupied by the pores and the scaffold. Consequently, we can estimate the elastic modulus of the scaffold. We conclude that this particular foam like microstructure should be considered as a key factor for the transport of particulate matter which plays a central role in mucus function with respect to particle penetration. The mesh properties composed of very different components are responsible for macroscopic and microscopic behavior being part of particles fate after landing.Comment: Accepted for publication in the Journal of the Mechanical Behavior of Biomedical Material

    Probing Pauli Blocking Factors in Quantum Pumps with Broken Time-Reversal Symmetry

    Full text link
    A recently demonstrated quantum electron pump is discussed within the framework of photon-assisted tunneling. Due to lack of time-reversal symmetry, different results are obtained for the pump current depending on whether or not final-state Pauli blocking factors are used when describing the tunneling process. Whilst in both cases the current depends quadratically on the driving amplitude for moderate pumping, a marked difference is predicted for the temperature dependence. With blocking factors the pump current decreases roughly linearly with temperature until k_B T ~ \hbar\omega is reached, whereas without them it is unaffected by temperature, indicating that the entire Fermi sea participates in the electronic transport.Comment: 4 pages in RevTex4 (beta4), 6 figures; status: to appear in PR

    Reducing sample variance: halo biasing, non-linearity and stochasticity

    Get PDF
    Comparing clustering of differently biased tracers of the dark matter distribution offers the opportunity to reduce the cosmic variance error in the measurement of certain cosmological parameters. We develop a formalism that includes bias non-linearities and stochasticity. Our formalism is general enough that can be used to optimise survey design and tracers selection and optimally split (or combine) tracers to minimise the error on the cosmologically interesting quantities. Our approach generalises the one presented by McDonald & Seljak (2009) of circumventing sample variance in the measurement of fdlnD/dlnaf\equiv d \ln D/d\ln a. We analyse how the bias, the noise, the non-linearity and stochasticity affect the measurements of DfDf and explore in which signal-to-noise regime it is significantly advantageous to split a galaxy sample in two differently-biased tracers. We use N-body simulations to find realistic values for the parameters describing the bias properties of dark matter haloes of different masses and their number density. We find that, even if dark matter haloes could be used as tracers and selected in an idealised way, for realistic haloes, the sample variance limit can be reduced only by up to a factor σ2tr/σ1tr0.6\sigma_{2tr}/\sigma_{1tr}\simeq 0.6. This would still correspond to the gain from a three times larger survey volume if the two tracers were not to be split. Before any practical application one should bear in mind that these findings apply to dark matter haloes as tracers, while realistic surveys would select galaxies: the galaxy-host halo relation is likely to introduce extra stochasticity, which may reduce the gain further.Comment: 21 pages, 13 figures. Published version in MNRA
    corecore