1,181 research outputs found

    Laser microscopy of tunneling magnetoresistance in manganite grain-boundary junctions

    Full text link
    Using low-temperature scanning laser microscopy we directly image electric transport in a magnetoresistive element, a manganite thin film intersected by a grain boundary (GB). Imaging at variable temperature allows reconstruction and comparison of the local resistance vs temperature for both, the manganite film and the GB. Imaging at low temperature also shows that the GB switches between different resistive states due to the formation and growth of magnetic domains along the GB. We observe different types of domain wall growth; in most cases a domain wall nucleates at one edge of the bridge and then proceeds towards the other edge.Comment: 5 pages, 4 figures; submitted to Phys. Rev. Let

    Isolas of 2-Pulse Solutions in Homoclinic Snaking Scenarios

    Get PDF
    Homoclinic snaking refers to the bifurcation structure of symmetric localised roll patterns that are often found to lie on two sinusoidal “snaking” bifurcation curves, which are connected by an infinite number of “rung” segments along which asymmetric localised rolls of various widths exist. The envelopes of all these structures have a unique maximum and we refer to them as symmetric or asymmetric 1-pulses. In this paper, the existence of stationary 1D patterns of symmetric 2-pulses that consist of two well-separated 1-pulses is established. Corroborating earlier numerical evidence, it is shown that symmetric 2-pulses exist along isolas in parameter space that are formed by parts of the snaking curves and the rungs mentioned above

    Testing for Antiphospholipid Antibody (aPL) Specificities in Retrospective “Normal” Cerebral Spinal Fluid (CSF)

    Get PDF
    Antiphospholipid antibodies (aPL) have been found in the blood of patients with systemic and neurological disease. The rare reports of aPL in cerebral spinal fluid (CSF) have been limited mostly to IgG and IgM anticardiolipin (aCL). Our published finding of IgA aPE in the CSF of a young stroke victim prompted us to establish “normal” CSF aPL values for a panel of aPL, which included aCL, antiphosphatidylserine (aPS), antiphosphatidylethanolamine (aPE) and antiphosphatidylcholine (aPC). CSF samples were tested by ELISA for IgG, IgM and IgA aPL. In addition, the CSF samples were tested for activity in the presence and absence of phospholipid (PL) binding plasma-proteins. A total of 24 data points were obtained for each CSF sample.We tested 59 CSF samples obtained from 59 patients who were undergoing evaluation for systemic or neurologic diseases. All CSF samples had normal protein, glucose and cell counts. Ten of the 59 CSF samples (17%) had elevated aPL optical density (OD) values an order of magnitude higher than the other 49 CSF samples for one or more aPL specificity and/or isotype. One CSF sample had both PL-binding protein dependent and independent IgG aPE activity. Another CSF sample showed both IgG aPE and aPC reactivity. The remaining eight CSF samples showed single aPL findings; IgG aPE (5), IgG aPC (1), IgG aCL (1) and IgM aPC (1). Seven of 10 patients with elevated CSF values were females. As expected, most “normal” aPL OD values were substantially lower in CSF than those we have reported in blood samples from volunteer blood donors

    Design, Development and Testing of the Miniature Autonomous Extravehicular Robotic Camera (Mini AERCam) Guidance, Navigation and Control System

    Get PDF
    Engineers at NASA Johnson Space Center have designed, developed, and tested a nanosatellite-class free-flyer intended for future external inspection and remote viewing of human spaceflight activities. The technology demonstration system, known as the Miniature Autonomous Extravehicular Robotic Camera (Mini AERCam), has been integrated into the approximate form and function of a flight system. The primary focus has been to develop a system capable of providing external views of the International Space Station. The Mini AERCam system is spherical-shaped and less than eight inches in diameter. It has a full suite of guidance, navigation, and control hardware and software, and is equipped with two digital video cameras and a high resolution still image camera. The vehicle is designed for either remotely piloted operations or supervised autonomous operations. Tests have been performed in both a six degree-of-freedom closed-loop orbital simulation and on an air-bearing table. The Mini AERCam system can also be used as a test platform for evaluating algorithms and relative navigation for autonomous proximity operations and docking around the Space Shuttle Orbiter or the ISS

    Gap solitons in Bragg gratings with a harmonic superlattice

    Full text link
    Solitons are studied in a model of a fiber Bragg grating (BG) whose local reflectivity is subjected to periodic modulation. The superlattice opens an infinite number of new bandgaps in the model's spectrum. Averaging and numerical continuation methods show that each gap gives rise to gap solitons (GSs), including asymmetric and double-humped ones, which are not present without the superlattice.Computation of stability eigenvalues and direct simulation reveal the existence of completely stable families of fundamental GSs filling the new gaps - also at negative frequencies, where the ordinary GSs are unstable. Moving stable GSs with positive and negative effective mass are found too.Comment: 7 pages, 3 figures, submitted to EP

    Insulin clearance and the incidence of type 2 diabetes in Hispanics and African Americans: the IRAS Family Study.

    Get PDF
    ObjectiveWe aimed to identify factors that are independently associated with the metabolic clearance rate of insulin (MCRI) and to examine the association of MCRI with incident type 2 diabetes in nondiabetic Hispanics and African Americans.Research design and methodsWe investigated 1,116 participants in the Insulin Resistance Atherosclerosis Study (IRAS) Family Study with baseline examinations from 2000 to 2002 and follow-up examinations from 2005 to 2006. Insulin sensitivity (S(I)), acute insulin response (AIR), and MCRI were determined at baseline from frequently sampled intravenous glucose tolerance tests. MCRI was calculated as the ratio of the insulin dose over the incremental area under the curve of insulin. Incident diabetes was defined as fasting glucose ≥126 mg/dL or antidiabetic medication use by self-report.ResultsWe observed that S(I) and HDL cholesterol were independent positive correlates of MCRI, whereas fasting insulin, fasting glucose, subcutaneous adipose tissue, visceral adipose tissue, and AIR were independent negative correlates (all P < 0.05) at baseline. After 5 years of follow-up, 71 (6.4%) participants developed type 2 diabetes. Lower MCRI was associated with a higher risk of incident diabetes after adjusting for demographics, lifestyle factors, HDL cholesterol, indexes of obesity and adiposity, and insulin secretion (odds ratio 2.01 [95% CI 1.30-3.10], P = 0.0064, per one-SD decrease in loge-transformed MCRI).ConclusionsOur data showed that lower MCRI predicts the incidence of type 2 diabetes

    Antiphospholipid autoantibodies as blood biomarkers for detection of early stage Alzheimer's disease

    Get PDF
    A robust blood biomarker is urgently needed to facilitate early prognosis for those at risk for Alzheimer's disease (AD). Redox reactive autoantibodies (R-RAAs) represent a novel family of antibodies detectable only after exposure of cerebrospinal fluid (CSF), serum, plasma or immunoglobulin fractions to oxidizing agents. We have previously reported that R-RAA antiphospholipid antibodies (aPLs) are significantly decreased in the CSF and serum of AD patients compared to healthy controls (HCs). These studies were extended to measure R-RAA aPL in serum samples obtained from Alzheimer's Disease Neuroimaging Initiative (ADNI). Serum samples from the ADNI-1 diagnostic groups from participants with mild cognitive impairment (MCI), AD and HCs were blinded for diagnosis and analyzed for R-RAA aPL by ELISA. Demographics, cognitive data at baseline and yearly follow-up were subsequently provided by ADNI after posting assay data. As observed in CSF, R-RAA aPL in sera from the AD diagnostic group were significantly reduced compared to HC. However, the sera from the MCI population contained significantly elevated R-RAA aPL activity relative to AD patient and/or HC sera. The data presented in this study indicate that R-RAA aPL show promise as a blood biomarker for detection of early AD, and warrant replication in a larger sample. Longitudinal testing of an individual for increases in R-RAA aPL over a previously established baseline may serve as a useful early sero-epidemiologic blood biomarker for individuals at risk for developing dementia of the Alzheimer's type
    • …
    corecore