2,070 research outputs found

    The 1996 research assessment exercise : the library and information management panel

    Get PDF
    Reports on the 1996 Research Assessment Exercise (RAE), the fourth such exercise aimed at providing funding councils of UK universities (including former polytechnics) with the necessary data to rate the quality of UK academic research for predetermined units of assessment in order to fund research selectively. Previous RAEs were conducted in 1986, 1989, and 1992 (for a report of the 1992 RAE see JOLIS 26 (3) Sep 94, 141-7 (LISA ref. 9409765)). Reports generally on the work of the Library and Information Management Panel in agreeing criteria specific to their assessment task, particularly the five principal modes of publication: research monographs; articles in scholarly periodicals; refereed conference papers; published research reports; and book chapters. Discusses the methodology used by the Panel, research submissions received and the overall results

    Monitoring clinical quality in rare disease services – experience in England

    Get PDF
    After some well-publicised problems with paediatric cardiac surgery, there has been great interest in England in monitoring clinical quality in specialised medical services. The National Commissioning Group plans, funds and monitors a set of highly specialised services for the National Health Service in England. We have developed systems for monitoring clinical quality that perform two interrelated but distinct functions: performance measurement and performance improvement. The aim is to collect information on all patients seen during each year – a 100% consecutive case series. Generally, there is no conceptual difficulty identifying an appropriate outcome for surgical interventions: the indication for surgery usually defines the outcome to monitor. This is not so for the medical and psychiatric services, where the relevant outcome to monitor is sometimes not obvious. There are a number of problems in interpreting, and acting on, outcome data for rare conditions and treatments. These problems include statistical problems due to small numbers, the need to risk adjust data and coding problems

    Hirschsprung's disease in the newborn

    Full text link
    The records of all patients with Hirschsprung's disease diagnosed and treated at our institution between 1 July 1974 and 31 August 1985 were reviewed. Of these 99 patients, 35 (35%) presented and were diagnosed within the first 30 days of life and constitute the basis of the present study group. Twenty-two infants (63%) had standard rectosigmoid disease with a male-to-female ratio of 2.2:1. Only one infant was premature. The spectrum of presenting signs included abdominal distension in 19 (54%), failure to pass meconium within the first 48 h of life in 16 (46%), “constipation” in 12 (34%), and vomiting in 9 (26%). Intestinal perforation was a presenting sign in 2 patients (6%) and enterocolitis occurred preoperatively in 4 (12%). Evaluation was facilitated by diagnostic barium enema in 60% of the patients. In those infants able to undergo elective evaluation, the definitive diagnosis was made by suction rectal biopsy, which was accurate in all cases. In addition to the high proportion of patients with long-segment disease (13 patients, 37%), there was a significant incidence of associated congenital anomalies (26%), including Down's syndrome in 5 (14%). Thirty-three of the 35 patients have undergone definitive treatment using the endorectal pull-through procedure, performed at an average age of 12 months, with no mortality related to the operation. In addition to highlighting the high incidence of congenital anomalies, the large proportion of neonates with long-segment disease, and the reliability of the diagnostic barium enema, this subgroup of patients with Hirschsprung's disease emphasizes the special diagnostic and management considerations required in the newborn infant who presents with sepsis of unknown etiology, intestinal obstruction, or constipation. A high index of suspicion, liberal use of suction rectal biopsy, early leveling colostomy, and definitive treatment by endorectal pull-through are important in achieving 0% operative mortality and excellent functional results.Peer Reviewedhttp://deepblue.lib.umich.edu/bitstream/2027.42/47145/1/383_2004_Article_BF00166865.pd

    π+\pi^+ photoproduction on the proton for photon energies from 0.725 to 2.875 GeV

    Full text link
    Differential cross sections for the reaction Îłp→nπ+\gamma p \to n \pi^+ have been measured with the CEBAF Large Acceptance Spectrometer (CLAS) and a tagged photon beam with energies from 0.725 to 2.875 GeV. Where available, the results obtained here compare well with previously published results for the reaction. Agreement with the SAID and MAID analyses is found below 1 GeV. The present set of cross sections has been incorporated into the SAID database, and exploratory fits have been made up to 2.7 GeV. Resonance couplings have been extracted and compared to previous determinations. With the addition of these cross sections to the world data set, significant changes have occurred in the high-energy behavior of the SAID cross-section predictions and amplitudes.Comment: 18 pages, 10 figure

    Fatigue in low-grade glioma

    Get PDF
    Contains fulltext : 80675.pdf (publisher's version ) (Closed access)The aim of this study was to determine the prevalence and severity of fatigue in long-term survivors with a low-grade glioma (LGG), and to analyze the relationship between fatigue and demographic variables, disease duration, tumor characteristics, former tumor treatment modalities, antiepileptic drug (AED) use, self-reported concentration, motivation, and activity. Fifty-four patients with stable disease (age range, 25-73 years) who were diagnosed and treated more than 8 years ago were included in this study. Fatigue was analyzed with the Checklist Individual Strength (CIS). Thirty-nine percent of the LGG patients were severely fatigued, with older patients being most affected. Severe fatigue was associated with AED use, and with reduced self-reported concentration, motivation, and activity. No relation was found between fatigue and gender, histology, tumor laterality, disease duration, type of neurosurgical intervention and radiation treatment. Fatigue is a severe problem in a large proportion of long-term surviving LGG patients

    Differential cross sections and spin density matrix elements for the reaction gamma p -> p omega

    Full text link
    High-statistics differential cross sections and spin density matrix elements for the reaction gamma p -> p omega have been measured using the CLAS at Jefferson Lab for center-of-mass (CM) energies from threshold up to 2.84 GeV. Results are reported in 112 10-MeV wide CM energy bins, each subdivided into cos(theta_CM) bins of width 0.1. These are the most precise and extensive omega photoproduction measurements to date. A number of prominent structures are clearly present in the data. Many of these have not previously been observed due to limited statistics in earlier measurements

    Observation of an Exotic S=+1S=+1 Baryon in Exclusive Photoproduction from the Deuteron

    Full text link
    In an exclusive measurement of the reaction Îłd→K+K−pn\gamma d \to K^+ K^- p n, a narrow peak that can be attributed to an exotic baryon with strangeness S=+1S=+1 is seen in the K+nK^+n invariant mass spectrum. The peak is at 1.542±0.0051.542\pm 0.005 GeV/c2^2 with a measured width of 0.021 GeV/c2^2 FWHM, which is largely determined by experimental mass resolution. The statistical significance of the peak is 5.2±0.6σ5.2 \pm 0.6 \sigma. The mass and width of the observed peak are consistent with recent reports of a narrow S=+1S=+1 baryon by other experimental groups.Comment: 5 pages, 5 figure

    Measurement of Beam-Spin Asymmetries for Deep Inelastic π+\pi^+ Electroproduction

    Full text link
    We report the first evidence for a non-zero beam-spin azimuthal asymmetry in the electroproduction of positive pions in the deep-inelastic region. Data have been obtained using a polarized electron beam of 4.3 GeV with the CLAS detector at the Thomas Jefferson National Accelerator Facility (JLab). The amplitude of the sinâĄÏ•\sin\phi modulation increases with the momentum of the pion relative to the virtual photon, zz, with an average amplitude of 0.038±0.005±0.0030.038 \pm 0.005 \pm 0.003 for 0.5<z<0.80.5 < z < 0.8 range.Comment: 5 pages, RevTEX4, 3 figures, 2 table

    Search for the Θ+\Theta^+ pentaquark in the reaction γd→pK−K+n\gamma d \to p K^- K^+ n

    Full text link
    A search for the \thp in the reaction Îłd→pK−K+n\gamma d \to pK^-K^+n was completed using the CLAS detector at Jefferson Lab. A study of the same reaction, published earlier, reported the observation of a narrow \thp resonance. The present experiment, with more than 30 times the integrated luminosity of our earlier measurement, does not show any evidence for a narrow pentaquark resonance. The angle-integrated upper limit on \thp production in the mass range of 1.52 to 1.56 GeV/c2^2 for the Îłd→pK−Θ+\gamma d \to pK^-\Theta^+ reaction is 0.3 nb (95% CL). This upper limit depends on assumptions made for the mass and angular distribution of \thp production. Using \lamstar production as an empirical measure of rescattering in the deuteron, the cross section upper limit for the elementary Îłn→K−Θ+\gamma n \to K^-\Theta^+ reaction is estimated to be a factor of 10 higher, {\it i.e.}, ∌3\sim 3 nb (95% CL).Comment: 5 figures, submitted to PRL, revised for referee comment

    Measurement of the Polarized Structure Function σLTâ€Č\sigma_{LT^\prime} for p(e⃗,eâ€Čp)πop(\vec{e},e'p)\pi^o in the Δ(1232)\Delta(1232) Resonance Region

    Full text link
    The polarized longitudinal-transverse structure function σLTâ€Č\sigma_{LT^\prime} has been measured in the Δ(1232)\Delta(1232) resonance region at Q2=0.40Q^2=0.40 and 0.65 GeV2^2. Data for the p(e⃗,eâ€Čp)πop(\vec e,e'p)\pi^o reaction were taken at Jefferson Lab with the CEBAF Large Acceptance Spectrometer (CLAS) using longitudinally polarized electrons at an energy of 1.515 GeV. For the first time a complete angular distribution was measured, permitting the separation of different non-resonant amplitudes using a partial wave analysis. Comparison with previous beam asymmetry measurements at MAMI indicate a deviation from the predicted Q2Q^2 dependence of σLTâ€Č\sigma_{LT^{\prime}} using recent phenomenological models.Comment: 5 pages, LaTex, 4 eps figures: to be published in PRC/Rapid Communications. Version 2 has revised Q^2 analysi
    • 

    corecore