829 research outputs found

    Outcomes of total hip arthroplasty, as a salvage procedure, following failed internal fixation of intracapsular fractures of the femoral neck: a systematic review and meta-analysis.

    Get PDF
    AIMS: The optimal management of intracapsular fractures of the femoral neck in independently mobile patients remains open to debate. Successful fixation obviates the limitations of arthroplasty for this group of patients. However, with fixation failure rates as high as 30%, the outcome of revision surgery to salvage total hip arthroplasty (THA) must be considered. We carried out a systematic review to compare the outcomes of salvage THA and primary THA for intracapsular fractures of the femoral neck. PATIENTS AND METHODS: We performed a Preferred Reporting Items for Systematic Reviews and Meta-Analysis (PRISMA) compliant systematic review, using the PubMed, EMBASE and Cochrane libraries databases. A meta-analysis was performed where possible, and a narrative synthesis when a meta-analysis was not possible. RESULTS: Our analyses revealed a significantly increased risk of complications including deep infection, early dislocation and peri-prosthetic fracture with salvage THA when compared with primary THA for an intracapsular fracture of the femoral neck (overall risk ratio of 3.15). Functional outcomes assessment using EuroQoL (EQ)-5D were not significantly different (p = 0.3). CONCLUSION: Salvage THA carries a significantly higher risk of complications than primary THA for intracapsular fractured neck of femur. Current literature is still lacking well designed studies to provide a full answer to the question. TAKE HOME MESSAGE: Salvage THA is associated with more complications than primary THA for intracapsular neck of femur fractures

    Bladder stones – red herring for resurgence of spasticity in a spinal cord injury patient with implantation of Medtronic Synchromed pump for intrathecal delivery of baclofen – a case report

    Get PDF
    BACKGROUND: Increased spasms in spinal cord injury (SCI) patients, whose spasticity was previously well controlled with intrathecal baclofen therapy, are due to (in order of frequency) drug tolerance, increased stimulus, low reservoir volume, catheter malfunction, disease progression, human error, and pump mechanical failure. We present a SCI patient, in whom bladder calculi acted as red herring for increased spasticity whereas the real cause was spontaneous extrusion of catheter from intrathecal space. CASE PRESENTATION: A 44-year-old male sustained a fracture of C5/6 and incomplete tetraplegia at C-8 level. Medtronic Synchromed pump for intrathecal baclofen therapy was implanted 13 months later to control severe spasticity. The tip of catheter was placed at T-10 level. The initial dose of baclofen was 300 micrograms/day of baclofen, administered by a simple continuous infusion. During a nine-month period, he required increasing doses of baclofen (875 micrograms/day) to control spasticity. X-ray of abdomen showed multiple radio opaque shadows in the region of urinary bladder. No malfunction of the pump was detected. Therefore, increased spasticity was attributed to bladder stones. Electrohydraulic lithotripsy of bladder stones was carried out successfully. Even after removal of bladder stones, this patient required further increases in the dose of intrathecal baclofen (950, 1050, 1200 and then 1300 micrograms/day). Careful evaluation of pump-catheter system revealed that the catheter had extruded spontaneously and was lying in the paraspinal space at L-4, where the catheter had been anchored before it entered the subarachnoid space. A new catheter was passed into the subarachnoid space and the tip of catheter was located at T-8 level. The dose of intrathecal baclofen was decreased to 300 micrograms/day. CONCLUSION: Vesical calculi acted as red herring for resurgence of spasticity. The real cause for increased spasms was spontaneous extrusion of whole length of catheter from subarachnoid space. Repeated bending forwards and straightening of torso for pressure relief and during transfers from wheel chair probably contributed to spontaneous extrusion of catheter from spinal canal in this patient

    Karyotype differentiation in three species of Tripogandra Raf. (Commelinaceae) with different ploidy levels

    Get PDF
    Most species of the genus Tripogandra (Commelinaceae) are taxonomically poorly circumscribed, in spite of having a relatively stable basic number x = 8. Aiming to estimate the cytological variation among Tripogandra species carrying this base number, several structural karyotypic characters were investigated in the diploid T. glandulosa, the hexaploid T. serrulata, and the octoploid T. diuretica. A careful evaluation of chromosome size and morphology did not reveal clear chromosome homeologies among karyotypes. The mean chromosome size was strongly reduced in the octoploid species, but not in the hexaploid species. They also differed largely in the CMA+ banding pattern and in the number of 5S and 45S rDNA sites per monoploid chromosome complement. All three species showed proximal DAPI + heterochromatin, although in T. serrulata this kind of heterochromatin was only visible after FISH. Further, the meiosis in T. serrulata was highly irregular, suggesting that this species has a hybrid origin. The data indicate that, in spite of the conservation of the base number, these species are karyologically quite different from each other

    Conductive Polymer Combined Silk Fiber Bundle for Bioelectrical Signal Recording

    Get PDF
    Electrode materials for recording biomedical signals, such as electrocardiography (ECG), electroencephalography (EEG) and evoked potentials data, are expected to be soft, hydrophilic and electroconductive to minimize the stress imposed on living tissue, especially during long-term monitoring. We have developed and characterized string-shaped electrodes made from conductive polymer with silk fiber bundles (thread), which offer a new biocompatible stress free interface with living tissue in both wet and dry conditions

    Stereoselective handling of perhexiline:Implications regarding accumulation within the human myocardium

    Get PDF
    Purpose: Perhexiline is a prophylactic anti-ischaemic agent with weak calcium antagonist effect which has been increasingly utilised in the management of refractory angina. The metabolic clearance of perhexiline is modulated by CYP2D6 metaboliser status and stereoselectivity. The current study sought to (1) determine whether the acute accumulation of perhexiline in the myocardium is stereoselective and (2) investigate the relationship between duration of short-term therapy and the potential stereoselective effects of perhexiline within myocardium. Method: Patients (n = 129) from the active arm of a randomised controlled trial of preoperative perhexiline in cardiac surgery were treated with oral perhexiline for a median of 9 days. Correlates of atrial and ventricular concentrations of enantiomers were sought via univariate followed by multivariate analyses. Results: Myocardial uptake of both (+) and (−) perhexiline was greater in ventricles than in atria, and there was more rapid clearance of (−) than (+) perhexiline. The main determinants of atrial uptake of both (+) and (−) perhexiline were the plasma concentrations [(+) perhexiline: β = −0.256, p = 0.015; (−) perhexiline: β = −0.347, p = 0.001] and patients’ age [(+) perhexiline: β = 0.300, p = 0.004; (−) perhexiline: β = 0.288, p = 0.005]. Atrial uptake of (+) enantiomer also varied directly with duration of therapy (β = 0.228, p = 0.025), while atrial uptake of (−) perhexiline varied inversely with simultaneous heart rate (β = −0.240, p = 0.015). Conclusion: (1) Uptake of both perhexiline enantiomers into atrium is greater with advanced age and displays evidence of both saturability and minor stereoselectivity. (2) Atrial uptake of (−) perhexiline may selectively modulate heart rate reduction

    Anti-ischemic therapy and stress testing: pathophysiologic, diagnostic and prognostic implications

    Get PDF
    Anti-ischemic therapy, in particular beta-blockers, is the most commonly employed drug for the control of myocardial ischemia in patients with stable coronary artery disease. Its widespread use also in patients with suspected coronary artery disease has important practical, clinical diagnostic and prognostic implications because diagnostic tests are heavily influenced by its effects. In the present review, the pathophysiological mechanisms of ischemia protection by antianginal therapy are described. Not all stressors are created equal in front of the different classes of antianginal drugs and on their turn the different classes of drugs exert different levels of protection on inducible ischemia. Several clinical implications can be drawn: From the diagnostic viewpoint antianginal therapy decreases test sensitivity, offsetting the real ischemic burden for a too high percentage of false negative tests. From the prognostic viewpoint test positivity in medical therapy identifies a group of subjects at higher risk of experiencing cardiac death and positivity on medical therapy can be considered a parameter of ischemia severity. Nonetheless in patients with known coronary artery disease the ability of antianginal therapy to modify the ischemic threshold at stress testing represent a powerful means to assess therapy efficacy. From a practical viewpoint, the use of antianginal therapy at time of testing has advantages and disadvantages which are largely dependent on the purpose a test is performed: if the purpose of testing is to diagnose ischemia, it should be performed in the absence of antianginal medications. If the purpose of testing is to assess the protective effects of antianginal therapy, the test should be performed on medications

    Lensfree Fluorescent On-Chip Imaging of Transgenic Caenorhabditis elegans Over an Ultra-Wide Field-of-View

    Get PDF
    We demonstrate lensfree on-chip fluorescent imaging of transgenic Caenorhabditis elegans (C. elegans) over an ultra-wide field-of-view (FOV) of e.g., >2–8 cm2 with a spatial resolution of ∼10µm. This is the first time that a lensfree on-chip platform has successfully imaged fluorescent C. elegans samples. In our wide-field lensfree imaging platform, the transgenic samples are excited using a prism interface from the side, where the pump light is rejected through total internal reflection occurring at the bottom facet of the substrate. The emitted fluorescent signal from C. elegans samples is then recorded on a large area opto-electronic sensor-array over an FOV of e.g., >2–8 cm2, without the use of any lenses, thin-film interference filters or mechanical scanners. Because fluorescent emission rapidly diverges, such lensfree fluorescent images recorded on a chip look blurred due to broad point-spread-function of our platform. To combat this resolution challenge, we use a compressive sampling algorithm to uniquely decode the recorded lensfree fluorescent patterns into higher resolution images, demonstrating ∼10 µm resolution. We tested the efficacy of this compressive decoding approach with different types of opto-electronic sensors to achieve a similar resolution level, independent of the imaging chip. We further demonstrate that this wide FOV lensfree fluorescent imaging platform can also perform sequential bright-field imaging of the same samples using partially-coherent lensfree digital in-line holography that is coupled from the top facet of the same prism used in fluorescent excitation. This unique combination permits ultra-wide field dual-mode imaging of C. elegans on a chip which could especially provide a useful tool for high-throughput screening applications in biomedical research

    Comparison of digital and conventional impression techniques: evaluation of patients’ perception, treatment comfort, effectiveness and clinical outcomes

    Get PDF
    Background: The purpose of this study was to compare two impression techniques from the perspective of patient preferences and treatment comfort.Methods: Twenty-four (12 male, 12 female) subjects who had no previous experience with either conventional or digital impression participated in this study. Conventional impressions of maxillary and mandibular dental arches were taken with a polyether impression material (Impregum, 3 M ESPE), and bite registrations were made with polysiloxane bite registration material (Futar D, Kettenbach). Two weeks later, digital impressions and bite scans were performed using an intra-oral scanner (CEREC Omnicam, Sirona). Immediately after the impressions were made, the subjects' attitudes, preferences and perceptions towards impression techniques were evaluated using a standardized questionnaire. The perceived source of stress was evaluated using the State-Trait Anxiety Scale. Processing steps of the impression techniques (tray selection, working time etc.) were recorded in seconds. Statistical analyses were performed with the Wilcoxon Rank test, and p < 0.05 was considered significant.Results: There were significant differences among the groups (p < 0.05) in terms of total working time and processing steps. Patients stated that digital impressions were more comfortable than conventional techniques.Conclusions: Digital impressions resulted in a more time-efficient technique than conventional impressions. Patients preferred the digital impression technique rather than conventional techniques
    • …